TOP > Various Settings of the Product > Product’s [Settings] Menu > [Tools] Menu > [HEX-Dump] > [Log Files] > [Copy] [Copy] Copy the log files of the product to the USB memory. Available only if you have installed the USB memory. A USB host cable (Mini-B) is required to connect a USB memory to the product. (1) USB host cable (Mini-B) (2) USB memory (3) USB connector • Be sure to perform a virus check on the USB memory before connecting it to the product. SATO Corporation shall not be held responsible for any product malfunctions caused by a virus spread via USB memory. The procedure to copy the log files is as follows: 1. Select the file type to copy and press the button. ◦ buff/ The buffer data saved when you perform the [Buffer Dump]. ◦ hexdump/ The received data created through [Hex Dump Mode]. 2. Select the file to copy and press the button. 3. The selected files have been copied to the USB memory. • When [Hex Dump Mode] is set to [Enabled], it may take some time before the files appear. Back to top