TOP > Various Settings of the Product > Product’s [Settings] Menu > [Printing] Menu > [Advanced] > [Calibrate] > Gap Sensor (PW208NX only) Gap Sensor (PW208NX only) Adjust the Gap sensor level manually. 1. Remove the label, and then set the liner. Align the liner so that the media sensor does not detect the I-Mark (black mark). 2. Close the cover. 3. Select [Calibrate] > [Gap Sensor] > [Emission Level]. 4. Press the button to change the Emit value so that the Sensor value is adjusted to 0.5 or lower. 5. Press the button to decide the value. 6. Select [Calibrate] > [Gap Sensor] > [Receiving Level]. 7. Press the button to change the Recv value so that the Sensor value is adjusted to meet the following: ◦ Sensor High value - Sensor Low value ≥ 1.0 V ◦ Sensor High value: Label + Liner parts ◦ Sensor Low value: Gap part Adjust the values so that the Sensor value in the Liner part is approximately 0.2 V to 0.3 V. Then, pull the media to check that the Label + Liner parts value - the Gap part value ≥ 1.0 V. 8. Press the button to decide the value. 9. Select [Calibrate] > [Gap Sensor] > [Slice Level]. 10. Press the button to change the slice level. Adjust the slice level so that it becomes the level calculated the following: (High value - Low value) x 0.7 + Low value = Slice Level 11. Press the button to decide the slice level. Back to top