CL4NX Plus/CL6NX Plus Operator Manual
SATO

MENU

How to Search

MENU

  • TOP (Table of Contents)
  • Getting Started
  • Searching from Category
  • Searching by Function Names
  • Searching According to What You Want to Do
  • Troubleshooting
  • Support and Warranty
Close
TOP > When You Are in Trouble > When an Error Message Appears > Error Message 1035 (I-mark Not Found)
Error Message 1035 (I-mark Not Found)
When there is an error with the product, the error message appears on the screen.
Check the cause and countermeasure, and then take appropriate action.
 
To clear the error:
Press the button (OFFLINE) or open/close the print head.
Cause and Countermeasure
Reference
Cause (1)
Meandering media.
Countermeasure (1)
Load the media correctly.
Loading the Media
Cause (2)
A label is attached to the media sensor.
Countermeasure (2)
Clean the media sensor.
Cleaning Using the Cleaning Kit
Cause (3)
The media sensor type is incorrect.
Countermeasure (3)
Set the media sensor type which is compatible with the media you use.
Media Sensor Type
Cause (4)
The media sensor level is incorrect.
Countermeasure (4)
Adjust the media sensor level.
Calibrate
Contact your SATO technical support if the error cannot be resolved.
Contact Information for When You Are in Trouble

Back to top

© 2023 SATO Corporation. All rights reserved.