TOP > Adjusting the Product > RFID Settings (RFID Models Only) > External Signal (EXT) Interfaces When RFID Mode Is Enabled
External Signal (EXT) Interfaces When RFID Mode Is Enabled
The following tables are the comparison of EXT signal between RFID mode is disabled or enabled.
 
RFID Mode Disabled
Standard specification is applied when the RFID mode is disabled.
Pin No.
Signal
I/O
1
Paper End
Output
2
Ground
-
3
Ribbon End
Output
4
Machine Error
Output
5
Print Start (PRIN)
Input
6
Print Done/Print End (PREND)
Output
7
Reprint (PRIN2)
Input
8
External Power Supply
Input
9
•
Print ready signal (MODE1)
•
Online/Offline (MODE2)
Output
10
Ribbon Near End
Output
11
N/A
-
12
+24V
Output
13
+5V
Output
14
Frame Ground
-
 
RFID Mode Enabled
The function indicated in bold text is applied to 1, 3, and 4 of Pin No. when the RFID mode is enabled.
Pin No.
Signal
I/O
1
Paper End + Ribbon End
Output
2
Ground
-
3
RFID Tag Error
Output
4
Machine Error/RFID Error
Output
5
Print Start (PRIN)
Input
6
Print Done/Print End (PREND)
Output
7
Reprint (PRIN2)
Input
8
External Power Supply
Input
9
•
Print ready signal (MODE1)
•
Online/Offline (MODE2)
Output
10
Ribbon Near End
Output
11
N/A
-
12
+24V
Output
13
+5V
Output
14
Frame Ground
-