[I-Mark Slice Level]
Set the I-mark sensor slice level.
The setting procedure is as follows:
1.
Use the following formula to calculate the slice level:
(High level - Low level) x 0.7 + Low level = slice level
2.
Tap [I-Mark Slice Level] in the [Calibrate] menu.
3.
Change the slice level value. Set the slice level to the slice level calculated in step 1.
4.
Tap to confirm the value.
 
•
If you set the slice level to 0.0 (V), the product sets the slice level automatically.
•
The changes to this setting are linked and are changed with the settings in the [Tools] > [Media Startup] menu.