[ESC+A] Start Code
CL4NX
CL6NX
CL4NX-J
CL6NX-J
PW208/PW208m
PW208NX/PW208mNX
FX3-LX
CT4-LX/HC4-LX
PW4NX
LR4NX-FA
S84NX/S86NX
CL4-SXR
CL6-SXR
Hexadecimal code
| ESC | <1B>16 |
|---|---|
| A | <41>16 |
Parameter
Nil
Initial value
Nil
Valid range and term of command
| When the power switch is OFF | The set command is not maintained. |
| Valid range within items | The set command becomes invalid. |
| Valid range between items | The set command becomes invalid. |
Function
Specifying the start of data transmission.
Format
<A>
Coding Example
<A>
<V>100<H>200<P>2<L>0202<XM>ABCD
<Q>2
<Z>
Supplementary Explanation
- Indicates the start of item and to be placed at the head of item.
- Use <A> and End of Data Transmission <Z> as a pair of commands.
Note
- Setting value of all commands excluding a part of system commands will be set to default.
- If this command is not specified, printing will not be performed.