[ESC+CR] Status 5 Reply Check Setting
CL4NX
CL6NX
CL4NX-J
CL6NX-J
PW208/PW208m
PW208NX/PW208mNX
FX3-LX (International)
CT4-LX/HC4-LX
PW4NX
LR4NX-FA
S84NX/S86NX
CL4-SXR
CL6-SXR
Hexadecimal code
| ESC | <1B>16 |
|---|---|
| CR | <43>16<52>16 |
Parameter
a,b
Initial value
a=0
Valid range and term of command
| When the power switch is OFF | The set parameter is maintained. |
| Valid range within items | The set parameter is valid until the next valid setting. |
| Valid range between items | The set command becomes invalid. |
Function
The BCC check of return and the item number check function are set up of the status 5.
Format
<CR>a,b
- Parameter
a [BCC check]
= 0: BCC check disable (initial value)
= 1: BCC check enable
b [Item number check] = 0: Not checked (fixed value) (omissible)
Coding Example
<A>
<ID>*****
<CR>1,0
<Z>
Supplementary Explanation
- [Item number check] is a fixed value.
- This command cannot be used at the same time the print data.
- Use is possible only during status 5 protocol.
- PW208/PW208m: Not support.