[ESC+ID] Job ID Number

CL4NX CL6NX CL4NX-J CL6NX-J PW208/PW208m PW208NX/PW208mNX FX3-LX CT4-LX/HC4-LX PW4NX LR4NX-FA S84NX/S86NX CL4-SXR CL6-SXR

Hexadecimal code

ESC <1B>16
ID <49>16<44>16

Parameter

aa
aaaaa

Initial value

a=<20>16

Valid range and term of command

When the power switch is OFF The set parameter is not maintained.
Valid range within items The set parameter is valid until the next valid setting.
Valid range between items The set command becomes invalid.

Function

Specifying job ID number for status return.

Format

<ID>aa

<ID>aaaaa

  • Parameter

    a [Job ID number]

    = Valid range: 00 to 99 (2digits)

    = Valid range: ****** or 00000 to 99999 (5digits) *1

    1. PW208/PW208m: Not support.

Coding Example

Job ID number: 01


<A>
<ID>01
<V>200<H>100<P>0<$>B,100,100,6
<$=>SATOPRINTER <Q>2 <Z>

Supplementary Explanation

  1. When status return is used for interface protocol, the specified job ID No. can be set to the telegraphic status.
  2. Status can be confirmed sending status request (ENQ).
  3. Include this command within items and use between start code <A> and stop code <Z>.
  4. When Status 5 is used, the valid range of job ID becomes "00000 to 99999" and "*****".

    If "*****" is specified, the item will not be managed by Job ID number.

Note

  1. In status return interface protocol, this command becomes valid when status request (ENQ) is received while printing (QTY≠0, includes at the time of Offline and Error).
  2. In status return communication protocol, if status request (ENQ) is received when printing is not in progress (QTY=0, No received data when power is ON), space (20H) will be set to status and returned.
  3. When Job ID Number <ID> is used more than twice within the items of <A> and <Z>, the last specified value becomes valid.

Supplementary explanation per model: PW2 series, PW4NX

  1. Status 5 is not within the specification. Format shall be <ID>aa only