[ESC+Q] Print Quantity

CL4NX CL6NX CL4NX-J CL6NX-J PW208/PW208m PW208NX/PW208mNX FX3-LX CT4-LX/HC4-LX PW4NX LR4NX-FA S84NX/S86NX CL4-SXR CL6-SXR

Hexadecimal code

ESC <1B>16
Q <51>16

Parameter

aaaaaa
aaaa

Initial value

aaaaaa=1
aaaa=1

Valid range and term of command

When the power switch is OFF The set parameter is not maintained.
Valid range within items The set parameter becomes invalid.
Valid range between items The set parameter becomes invalid.

Function

Specifying the number of labels to print.

Format

<Q>aaaaaa

* CL4NX/CL6NX/CL4NX-J/CL6NX-J, FX3-LX, CT4-LX/HC4-LX, PW4NX, LR4NX-FA, S84NX/S86NX

<Q>aaaa

* PW208/PW208m, PW208NX/PW208mNX

  • Parameter

    a [Number of labels to print] = Valid range: 1 to 999999

Coding Example

Number of labels: 2


<A>
<V>100<H>200<P>2<L>0202<XM>ABCD
<Q>2
<Z>

Supplementary Explanation

  1. Print contents specified by Start of Data Transmission <A> and End of Data Transmission <Z> are regarded as 1 label, and the number of reprints can be specified.
  2. Use this command prior to End of Data Transmission <Z>.

Note

  1. Reprint will be performed based on the specified print quantity. If specifying sequential numbering command <F>, the value of sequential number that was set up for that field portion will print.
  2. When this command is used in combination with Multiple Cutting <~>, the specified print quantity multiplied by specified value for cutting becomes the number of labels to print.

Initial value of parameter and Valid range

Model Initial value Valid range
CL4NX/CL4NX-J 1 1-999999
CL6NX/CL6NX-J 1 1-999999

PW208/PW208m

PW208NX/PW208mNX

1 1-9999
FX3-LX 1 1-999999
CT4-LX/HC4-LX 1 1-999999
PW4NX 1 1-999999
LR4NX-FA 1 1-999999
S84NX/S86NX 1 1-999999

Supplementary explanation per model: PW2 series, PW4NX, S84NX/S86NX

  1. Any commands related to cutter is not within the specifications.