[ESC+Q] Print Quantity
CL4NX
CL6NX
CL4NX-J
CL6NX-J
PW208/PW208m
PW208NX/PW208mNX
FX3-LX
CT4-LX/HC4-LX
PW4NX
LR4NX-FA
S84NX/S86NX
CL4-SXR
CL6-SXR
Hexadecimal code
| ESC | <1B>16 |
|---|---|
| Q | <51>16 |
Parameter
aaaaaa
aaaa
Initial value
aaaaaa=1
aaaa=1
Valid range and term of command
| When the power switch is OFF | The set parameter is not maintained. |
| Valid range within items | The set parameter becomes invalid. |
| Valid range between items | The set parameter becomes invalid. |
Function
Specifying the number of labels to print.
Format
<Q>aaaaaa
* CL4NX/CL6NX/CL4NX-J/CL6NX-J, FX3-LX, CT4-LX/HC4-LX, PW4NX, LR4NX-FA, S84NX/S86NX
<Q>aaaa
* PW208/PW208m, PW208NX/PW208mNX
-
Parameter
a [Number of labels to print] = Valid range: 1 to 999999
Coding Example
Number of labels: 2
<A>
<V>100<H>200<P>2<L>0202<XM>ABCD
<Q>2
<Z>
Supplementary Explanation
- Print contents specified by Start of Data Transmission <A> and End of Data Transmission <Z> are regarded as 1 label, and the number of reprints can be specified.
- Use this command prior to End of Data Transmission <Z>.
Note
- Reprint will be performed based on the specified print quantity. If specifying sequential numbering command <F>, the value of sequential number that was set up for that field portion will print.
- When this command is used in combination with Multiple Cutting <~>, the specified print quantity multiplied by specified value for cutting becomes the number of labels to print.
Initial value of parameter and Valid range
| Model | Initial value | Valid range |
|---|---|---|
| CL4NX/CL4NX-J | 1 | 1-999999 |
| CL6NX/CL6NX-J | 1 | 1-999999 |
|
PW208/PW208m PW208NX/PW208mNX |
1 | 1-9999 |
| FX3-LX | 1 | 1-999999 |
| CT4-LX/HC4-LX | 1 | 1-999999 |
| PW4NX | 1 | 1-999999 |
| LR4NX-FA | 1 | 1-999999 |
| S84NX/S86NX | 1 | 1-999999 |
Supplementary explanation per model: PW2 series, PW4NX, S84NX/S86NX
- Any commands related to cutter is not within the specifications.