[ESC+FW] Ruled / Grid Line Print

CL4NX CL6NX CL4NX-J CL6NX-J PW208/PW208m PW208NX/PW208mNX FX3-LX CT4-LX/HC4-LX PW4NX LR4NX-FA S84NX/S86NX CL4-SXR CL6-SXR

Hexadecimal code

ESC <1B>16
FW <46>16<57>16

Parameter

Rule aabccccc
Grid aabbVcccccHddddd

Initial value

Nil

Valid range and term of command

When the power switch is OFF The set parameter is not maintained.
Valid range within items The set parameter becomes invalid.
Valid range between items The set parameter becomes invalid.

Function

Specifying the ruled / grid line.

Format

<FW>aabccccc Print of ruled line

  • Parameter

    a [Line width] = Valid range: 02 to 99 dots

    b [Horizontal/vertical direction]

    = H: Horizontal direction

    = V: Vertical direction

    c [Ruled line length] = Valid range: Refer to the table below.


<FW>aabbVcccccHddddd Print of grid line

  • Parameter

    a [Vertical line width] = Valid range: 02 to 99 dots

    b [Horizontal line width] = Valid range: 02 to 99 dots

    c [Vertical line length] = Valid range: Refer to the table below.

    d [Horizontal line length] = Valid range: Refer to the table below.

Coding Example 1

Ruled line print, Line width: 4, Horizontal direction, Ruled line length: 400

Grid line print, Vertical line width: 8, Horizontal line width: 8, Vertical line length: 300, Horizontal line length: 400


<A>
<V>100<H>200<FW>04H400
<V>300<H>200<FW>0808V300H400
<Q>2
<Z>
                    

Supplementary Explanation

  1. When the print start position exceeds the printable area, the printing is not executed. (It doesn't raise a command error.)
  2. Set line width according to the table below so the horizontal line width is more than 0.166mm.
    Head density Line width
    8 dots/mm (203 dpi) 2 dots or more
    12 dots/mm (305 dpi) 2 dots or more
    24 dots/mm (609 dpi) 4 dots or more
  3. If setting the vertical line width wider, it will be widened to the right side against media feed direction. If setting the horizontal line width wider, it will be widened to the lower side against media feed direction.
  4. If setting the grid line wider, it will be widened inward.

Valid Range

Model Valid range: Horizontal (dots) Valid range: Vertical (dots)
CL4NX
CL4NX-J
203 dpi 1 to 832 1 to 20000
305 dpi 1 to 1248 1 to 18000
609 dpi 1 to 2496 1 to 9600
CL6NX
CL6NX-J
203 dpi 1 to 1216 (*1)
1 to 1340 (*2)
1 to 20000
305 dpi 1 to 1984 (*1)
1 to 2010 (*2)
1 to 18000
PW208
PW208m
PW208NX
PW208mNX
203 dpi 1 to 440 1 to 8000
FX3-LX 305 dpi 1 to 960 1 to 6000
CT4-LX
HC4-LX
203 dpi 1 to 832 1 to 20000
305 dpi 1 to 1248 1 to 18000
PW4NX 203 dpi 1 to 832 1 to 8000
LR4NX-FA 203 dpi 1 to 832 1 to 20000
305 dpi 1 to 1248 1 to 18000
609 dpi 1 to 2496 1 to 9600
S84NX 203 dpi 1 to 832 1 to 20000
305 dpi 1 to 1248 1 to 18000
609 dpi 1 to 2496 1 to 9600
S86NX 203 dpi 1 to 1340 1 to 20000
305 dpi 1 to 2010 1 to 18000
CL4-SXR 203 dpi 1 to 832 1 to 20000
305 dpi 1 to 1248 1 to 18000
609 dpi 1 to 2496 1 to 9600
CL6-SXR 203 dpi 1 to 1216 (*3)
1 to 1340 (*4)
1 to 20000
305 dpi 1 to 1984 (*3)
1 to 2010 (*4)
1 to 18000

CL6NX/CL6NX-J

  1. Valid range in the case of setting "Standard" is "Valid range for print"
  2. Valid range in the case of setting "Left-justify" is "Valid range for print"

  3. CL6-SXR

    The valid range depends on the setting of [Settings] > [Printing] > [Print Adjustments] > [Head Base Position].

  4. Valid range in the case of setting "Standard" is "Valid area for print position"(CL6-SXR(International) default value)
  5. Valid range in the case of setting "Left-justify" is "Valid area for print position"(CL6-SXR(Japan) default value)