Hexadecimal code
| ESC | <1B>16 |
|---|---|
| RM | <52>16<4D>16 |
Parameter
aaaa,bbbbb
Initial value
Nil
Valid range and term of command
| When the power switch is OFF | The set parameter is not maintained. |
| Valid range within items | The set parameter becomes invalid. |
| Valid range between items | The set parameter becomes invalid. |
Function
Performing mirror rotation of print data.
Format
<RM>aaaa,bbbbb
-
Parameter
a [Horizontal range of mirror rotation specification] = Valid range: Refer to the table below.
b [Vertical range of mirror rotation specification] = Valid range: Refer to the table below.
Coding Example 1
When the range of mirror rotation is specified:
<A>
<H>100<V>200<XS>12345
<H>100<V>200<RM>0200,0080
<Q>1
<Z>
Coding Example 2
When the range of mirror rotation is not specified:
<A>
<H>100<V>200<XS>12345
<RM>
<Z>
Supplementary Explanation
- When the parameter "aaaa" and "bbbbb" are not specified, all print data specified prior to this command will be rotated.
- Data outside of print area will not rotate.
- If specifying this command for the item that does not contain print data, the command error will occur.
- This command cannot be used in combination with the commands that associated with re-edition of print data. Refer to the invalid command for the list below. When invalid commands are specified, printing may not be correct.
- This command cannot be used in combination with some registration commands. Refer to the invalid command for the list below. When the command that cannot use in combination with is specified, print result is not guaranteed.
- This command cannot be used together with some of the modification commands. Refer to the invalid command for the list below. When the command that cannot use in combination with is specified, print result is not guaranteed.
- This command print the mirror image of the print data put before the mirror rotation command is specified. The data after the command don't rotate. Note that specifying this command several times results rotating the data several times.
- When the mirror image is applied for the barcode, reading of the barcode and the head damage check are not guaranteed.
- When executing the mirror image, the head damage check will be performed for all the areas where rotated.
Valid Range for start position of mirroring
| Model | Horizontal start position of mirror rotation specification (dots) | Vertical start position of mirror rotation specification (dots) | |
|---|---|---|---|
|
CL4NX CL4NX-J |
203 dpi | 1 to 832 | 1 to 20000 |
| 305 dpi | 1 to 1248 | 1 to 18000 | |
| 609 dpi | 1 to 2496 | 1 to 9600 | |
|
CL6NX CL6NX-J |
203 dpi | 1 to 1216 (*1) 1 to 1340 (*2) |
1 to 20000 |
| 305 dpi | 1 to 1984 (*1) 1 to 2010 (*2) |
1 to 18000 | |
| PW208 PW208m PW208NX PW208mNX |
203 dpi | 1 to 440 | 1 to 8000 |
| FX3-LX | 305 dpi | 1 to 960 | 1 to 6000 |
| CT4-LX HC4-LX |
203 dpi | 1 to 832 | 1 to 20000 |
| 305 dpi | 1 to 1248 | 1 to 18000 | |
| PW4NX | 203 dpi | 1 to 832 | 1 to 8000 |
| LR4NX-FA | 203 dpi | 1 to 832 | 1 to 20000 |
| 305 dpi | 1 to 1248 | 1 to 18000 | |
| 609 dpi | 1 to 2496 | 1 to 9600 | |
| S84NX | 203 dpi | 1 to 832 | 1 to 20000 |
| 305 dpi | 1 to 1248 | 1 to 18000 | |
| 609 dpi | 1 to 2496 | 1 to 9600 | |
| S86NX | 203 dpi | 1 to 1340 | 1 to 20000 |
| 305 dpi | 1 to 2010 | 1 to 18000 | |
| CL4-SXR | 203 dpi | 1 to 832 | 1 to 20000 |
| 305 dpi | 1 to 1248 | 1 to 18000 | |
| 609 dpi | 1 to 2496 | 1 to 9600 | |
| CL6-SXR | 203dpi | 1 to 1216 (*3) 1 to 1340 (*4) |
1 to 20000 |
| 305 dpi | 1 to 1984 (*3) 1 to 2010 (*4) |
1 to 18000 | |
Valid Range for mirror rotation
| Model | Horizontal range of mirror rotation (dots) | Vertical range of mirror rotation (dots) | |
|---|---|---|---|
|
CL4NX CL4NX-J |
203 dpi | 8 to 832 | 8 to 20000 |
| 305 dpi | 8 to 1248 | 8 to 18000 | |
| 609 dpi | 8 to 2498 | 8 to 9600 | |
|
CL6NX CL6NX-J |
203 dpi | 8 to 1216 (*1) 8 to 1340 (*2) |
8 to 20000 |
| 305 dpi | 8 to 1984 (*1) 8 to 2010 (*2) |
8 to 18000 | |
| PW208 PW208m PW208NX PW208mNX |
203 dpi | 8 to 440 | 8 to 8000 |
| FX3-LX | 305 dpi | 8 to 960 | 8 to 6000 |
| CT4-LX HC4-LX |
203 dpi | 8 to 832 | 8 to 20000 |
| 305 dpi | 8 to 1248 | 8 to 18000 | |
| PW4NX | 203 dpi | 8 to 832 | 8 to 8000 |
| LR4NX-FA | 203 dpi | 8 to 832 | 8 to 20000 |
| 305 dpi | 8 to 1248 | 8 to 18000 | |
| 609 dpi | 8 to 2498 | 8 to 9600 | |
| S84NX | 203 dpi | 8 to 832 | 8 to 20000 |
| 305 dpi | 8 to 1248 | 8 to 18000 | |
| 609 dpi | 8 to 2498 | 8 to 9600 | |
| S86NX | 203 dpi | 8 to 1340 | 8 to 20000 |
| 305 dpi | 8 to 2010 | 8 to 18000 | |
| CL4-SXR | 203 dpi | 8 to 832 | 8 to 20000 |
| 305 dpi | 8 to 1248 | 8 to 18000 | |
| 609 dpi | 8 to 2498 | 8 to 9600 | |
| CL6-SXR | 203 dpi | 8 to 1216 (*3) 8 to 1340 (*4) |
8 to 20000 |
| 305 dpi | 8 to 1984 (*3) 8 to 2010 (*4) |
8 to 18000 | |
CL6NX/CL6NX-J
- Valid range in the case of setting "Standard" is "Valid range for print"
- Valid range in the case of setting "Left-justify" is "Valid range for print"
- Valid range in the case of setting "Standard" is "Valid area for print position"(CL6-SXR(International) default value)
- Valid range in the case of setting "Left-justify" is "Valid area for print position"(CL6-SXR(Japan) default value)
CL6-SXR
The valid range depends on the setting of [Settings] > [Printing] > [Print Adjustments] > [Head Base Position].
Command that cannot use in combination with
Command that associated with reediting
<WD>
<F>
<(>
<0>
<WA>
Registration
<GI>
<GT>
<PI>
Modification
<%>
<R>