[ESC+BL] UPC-A Barcode (Without HRI)
CL4NX
CL6NX
CL4NX-J
CL6NX-J
PW208/PW208m
PW208NX/PW208mNX
FX3-LX
CT4-LX/HC4-LX
PW4NX
LR4NX-FA
S84NX/S86NX
CL4-SXR
CL6-SXR
Hexadecimal code
| ESC | <1B>16 |
|---|---|
| BL | <42>16<4C>16 |
Parameter
aabbcccn...n
Initial value
Nil
Valid range and term of command
| When the power switch is OFF | The set parameter is not maintained. |
| Valid range within items | The set parameter becomes invalid. |
| Valid range between items | The set parameter becomes invalid. |
Function
Set the height of character barcode of the first digit and the last digit to the same height of the guard bar.
Format
<BL>abbcccn...n
-
Parameter
a [Barcode type] = H : UPC-A (Fixed 'H')
b [Narrow bar] = Valid Range : 01-36 dots
c [Height of Barcode] = Valid Range : 001-999 dots
n [Print data] = Data : 11 fixed digits
Coding Example
Font type: UPC-A, Narrow bar width: 03, Barcode height: 120, Print data: 01234567890
<A>
<H>100<V>100<BL>H0312001234567890
<Q>2
<Z>
Supplementary Explanation
- This command supports UPC-A only. When barcode type is specified other than "H", command error occurs.
- Setting of Guard bar, HRI and ratio is described as follows.
Guard bar HRI Ratio Available Nil Fix - When the parameter value exceeds the range, operation is not supported.
- When printing UPC-A with <D>, all character barcodes have the same height. When <BL> is uses, the height of the character barcode of the start digit and the last digit have the same height of the guard bar.
UPC-A specifying <D>
UPC-A specifying <BL>