[ESC+BL] UPC-A Barcode (Without HRI)

CL4NX CL6NX CL4NX-J CL6NX-J PW208/PW208m PW208NX/PW208mNX FX3-LX CT4-LX/HC4-LX PW4NX LR4NX-FA S84NX/S86NX CL4-SXR CL6-SXR

Hexadecimal code

ESC <1B>16
BL <42>16<4C>16

Parameter

aabbcccn...n

Initial value

Nil

Valid range and term of command

When the power switch is OFF The set parameter is not maintained.
Valid range within items The set parameter becomes invalid.
Valid range between items The set parameter becomes invalid.

Function

Set the height of character barcode of the first digit and the last digit to the same height of the guard bar.

Format

<BL>abbcccn...n

  • Parameter

    a [Barcode type] = H : UPC-A (Fixed 'H')

    b [Narrow bar] = Valid Range : 01-36 dots

    c [Height of Barcode] = Valid Range : 001-999 dots

    n [Print data] = Data : 11 fixed digits

Coding Example

Font type: UPC-A, Narrow bar width: 03, Barcode height: 120, Print data: 01234567890


<A>
<H>100<V>100<BL>H0312001234567890
<Q>2
<Z>
                    

Supplementary Explanation

  1. This command supports UPC-A only. When barcode type is specified other than "H", command error occurs.
  2. Setting of Guard bar, HRI and ratio is described as follows.
    Guard bar HRI Ratio
    Available Nil Fix
  3. When the parameter value exceeds the range, operation is not supported.
  4. When printing UPC-A with <D>, all character barcodes have the same height. When <BL> is uses, the height of the character barcode of the start digit and the last digit have the same height of the guard bar.

    UPC-A specifying <D>


    UPC-A specifying <BL>