[ESC+BP] Postnet

CL4NX CL6NX CL4NX-J CL6NX-J PW208/PW208m PW208NX/PW208mNX FX3-LX CT4-LX/HC4-LX PW4NX LR4NX-FA S84NX/S86NX CL4-SXR CL6-SXR

Hexadecimal code

ESC <1B>16
BP <42>16<50>16

Parameter

n...n

Initial value

Nil

Valid range and term of command

When the power switch is OFF The set parameter is not maintained.
Valid range within items The set parameter becomes invalid.
Valid range between items The set parameter becomes invalid.

Function

Specifying customer barcode.

Format

<BP>n...n

  • Parameter

    n = Print data (Refer to the POSTNET Code Table)

    Note that the digits other than specified below are not allowed.

    • 5digits (POSTNET-32 format)
    • 6digits (POSTNET-37 format)
    • 9digits (POSTNET-52 format)
    • 11digits (POSTNET-62 Delivery Point format)

Coding Example

Postal code: 11 digits: 01234567890


<A>
<V>100<H>200<BP>01234567890
<Q>2
<Z>
                    

Supplementary Explanation

  1. If specifying the value other than 5, 6, 9, and 11 digits for print data, it will be ignored.
  2. Only numeric can be specified as print data.

Supplementary explanation per model: PW2 series

  1. Support only PW208NX/PW208mNX (International).

Supplementary explanation per model: FX3-LX series

  1. Support only FX3-LX (International)

Supplementary explanation per model: CT4-LX series

  1. Support only CT4-LX (International)

POSTNET Code table

SI SO
B8 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1
B7 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1
B6 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1
B5 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1
B4 B3 B2 B1 0 1 2 3 4 5 6 7 8 9 A B C D E F
0 0 0 0 0 0
0 0 0 1 1 1
0 0 1 0 2 2
0 0 1 1 3 3
0 1 0 0 4 4
0 1 0 1 5 5
0 1 1 0 6 6
0 1 1 1 7 7
1 0 0 0 8 8
1 0 0 1 9 9
1 0 1 0 A
1 0 1 1 B
1 1 0 0 C
1 1 0 1 D
1 1 1 0 E
1 1 1 1 F