[ESC+BV] MaxiCode (Compatible Command)

CL4NX CL6NX CL4NX-J CL6NX-J PW208/PW208m PW208NX/PW208mNX FX3-LX CT4-LX/HC4-LX PW4NX LR4NX-FA S84NX/S86NX CL4-SXR CL6-SXR

Hexadecimal code

ESC <1B>16
BV <42>16<56>16

Parameter

a,b,c,ddddddddd,eee,fff,n...n

Initial value

Nil

Valid range and term of command

When the power switch is OFF The set parameter is not maintained.
Valid range within items The set parameter becomes invalid.
Valid range between items The set parameter becomes invalid.

Function

Specifying MaxiCode.

Format

<BV>a,b,c,ddddddddd,eee,fff,n...n

  • Parameter

    a [Symbol number] = Valid Range: 1 to 8

    b [Number of symbol digit] = Valid Range: 1 to 8

    c [Mode]

    = 2: Transportation only

    = 3: Transportation only

    = 4: Standard symbol

    = 6: Reader programming

    d [Postal code]

    = Valid Range: 0 to 999999999 (Mode 2)

    = 000000 to 999999 (Mode 3)

    * Mode 2: Max 9 digits (Numeric only)

    * Mode 3: Fixed 6 digits (Capital alphabet)

    e [Country code] = Valid Range: 001 to 999

    f [Service class] = Valid Range: 001 to 999

    n [Low priority message] = Alphanumeric/Symbol


    Mode Service class Country code Postal code Maximum print data:
    Numeric only
    Maximum print data:
    Alphanumeric
    2 Fixed 3 digits
    (Numeric only)
    Fixed 3 digits
    (Numeric only)
    Max. 9 digits 123 84
    3 Fixed 6 digits
    (Alphanumeric)
    4 Omission 138 93
    6

Coding Example


<A>
<V>100<H>200<BV>1,1,2,123456789,001,002,SAHTHA
<Q>2
<Z>
                    

Supplementary Explanation

  1. Size of MaxiCode are not changed by number of data for printing.
  2. If parameter that is not described above is used, or print data doesn't match, symbol is not printed.
  3. When specifying mode 4 and mode 6, number of print data must be specified over 12. When number of print data is specified less than 11, scanner cannot read printed MaxiCode.

Supplementary explanation per model: PW2 series

  1. Support only PW208NX/PW208mNX (International).

Precautions during use

  1. This is the command of the old specification. Recommend the use of <2D20>.

MaxiCode Code table

SI SO
B8 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1
B7 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1
B6 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1
B5 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1
B4 B3 B2 B1 0 1 2 3 4 5 6 7 8 9 A B C D E F
0 0 0 0 0 SP 0 @ P ` p
0 0 0 1 1 ! 1 A Q a q
0 0 1 0 2 " 2 B R b r
0 0 1 1 3 # 3 C S c s
0 1 0 0 4 $ 4 D T d t
0 1 0 1 5 % 5 E U e u
0 1 1 0 6 & 6 F V f v
0 1 1 1 7 ' 7 G W g w
1 0 0 0 8 ( 8 H X h x
1 0 0 1 9 ) 9 I Y i y
1 0 1 0 A * : J Z j z
1 0 1 1 B + ; K [ k {
1 1 0 0 C , < L ¥ l |
1 1 0 1 D - = M ] m }
1 1 1 0 E . > N ^ n ~
1 1 1 1 F / ? O _ o DEL

MaxiCode can specify from 1H to FFH.