[ESC+BX] DataMatrix (ECC200) (Compatible Command)

CL4NX CL6NX CL4NX-J CL6NX-J PW208/PW208m PW208NX/PW208mNX FX3-LX CT4-LX/HC4-LX PW4NX LR4NX-FA S84NX/S86NX CL4-SXR CL6-SXR

Hexadecimal code

ESC <1B>16
BX <42>16<58>16

Parameter

aabbccddeeefffghh

Initial value

Nil

Valid range and term of command

When the power switch is OFF The set parameter is not maintained.
Valid range within items The set parameter becomes invalid.
Valid range between items The set parameter becomes invalid.

Function

Specifying DataMatrix (ECC200).

Format (Setup part)

<BX>aabbccddeeefffghh

  • Parameter

    a [Format ID] = Valid Range: 01 (Fixed)

    b [Error correction level] = Valid Range: 20 (Fixed)

    c [Cell width] = Valid Range: 01 to 99 (dot cell)

    d [Cell pitch] = Valid Range: 01 to 99 (dot cell)

    e [Number of cells per line]

    = Valid Range: 010 to 144

    = 000: (Auto setup)

    f [Number of cell lines]

    = Valid Range: 008 to 414

    = 000: (Auto setup)

    g [Mirror image] = Valid Range: 0 (Fixed)

    h [Size of guide cell] = Valid Range: 01 (Fixed)

Supplementary Explanation

  1. 01 and 02 are designable for [Cell width] and [Cell Pitch]; however, they may not be read properly. In this case, 00 will be an error.
  2. If 000 is specified for both [No. of cells per line] and [Number of cell lines], optimum matrix size is set automatically based on the Number of data.

Supplementary explanation per model: PW2 series

  1. Support only PW208NX/PW208mNX (International).

Precautions during use

  1. This is the command of the old specification. Recommend the use of <2D50>.