[ESC+DC] DataMatrix (ECC200) Data Specify (Compatible Command)
CL4NX
CL6NX
CL4NX-J
CL6NX-J
PW208/PW208m
PW208NX/PW208mNX
FX3-LX
CT4-LX/HC4-LX
PW4NX
LR4NX-FA
S84NX/S86NX
CL4-SXR
CL6-SXR
Hexadecimal code
| ESC | <1B>16 |
|---|---|
| DC | <44>16<43>16 |
Parameter
n...n
Initial value
Nil
Valid range and term of command
| When the power switch is OFF | The set parameter is not maintained. |
| Valid range within items | The set parameter becomes invalid. |
| Valid range between items | The set parameter becomes invalid. |
Function
Specifying data for DataMatrix (ECC200).
Format (Data specification part)
<DC>n...n
-
Parameter
n [Print data] = Data
Coding Example
Cell width: 02, Cell pitch: 02
Number of cells per line: 000 (Auto setup), Number of cell lines: 000 (Auto setup)
Print data: 1234567890
<A>
<V>100<H>200
<BX>01200202000000001
<DC>1234567890
<Q>2
<Z>
Supplementary Explanation
DataMatrix (ECC200) can specify from 00H to FFH except for printer control code of 05H, 10H, 11H, 12H, 18H, 1BH.
When specifying control code for data, use DataMatrix<2D50>.
| Data format | Number of data | |
|---|---|---|
| Data format | Numeric | 3116 |
| Alphanumeric | 2335 | |
| Binary (00H to FFH) | 1556 |
* Value in above table shows the maximum number of data that can be specified as barcode data.
Supplementary explanation per model: PW2 series
- Support only PW208NX/PW208mNX (International).
Precautions during use
- This is the command of the old specification. Recommend the use of <2D50>.