[ESC+FX] DataMatrix (ECC200) Sequential Number (Compatible Command)

CL4NX CL6NX CL4NX-J CL6NX-J PW208/PW208m PW208NX/PW208mNX FX3-LX CT4-LX/HC4-LX PW4NX LR4NX-FA S84NX/S86NX CL4-SXR CL6-SXR

Hexadecimal code

ESC <1B>16
FX <46>16<58>16

Parameter

aaabcccdddeee

Initial value

Nil

Valid range and term of command

When the power switch is OFF The set parameter is not maintained.
Valid range within items The set parameter becomes invalid.
Valid range between items The set parameter becomes invalid.

Function

Specifying sequential number for DataMatrix.

Format (Sequential number part)

<FX>aaabcccdddeee

  • Parameter

    a [Number of duplication to print] = Valid Range : 001 to 999

    b [Flag of increase and decrease]

    = + : Increment

    = - : Decrement

    c [Number of increase and decrease] = Valid Range : 001 to 999

    d [Specification of digit position] = Valid Range : 001 to 999

    e [Number of digit] = Valid Range : 001 to 999

Coding Example

Number of duplication to print: 001, Flag of increase and decrease: +, Number of increase and decrease: 001, Digit position: 005, Number of digit: 003


<A>
<V>100<H>200
<FX>001+001005003
<BX>01100202000000001
<DC>00006000
<Q>2
<Z>
                    

Supplementary explanation per model: PW2 series

  1. Support only PW208NX/PW208mNX (International).

Precautions during use

  1. This is the command of the old specification. Recommend the use of <2D50>.

GS1 DataMatrix (ECC200) Code table (<DC>)

SI SO
B8 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1
B7 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1
B6 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1
B5 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1
B4 B3 B2 B1 0 1 2 3 4 5 6 7 8 9 A B C D E F
0 0 0 0 0 SP 0 @ P ` p
0 0 0 1 1 ! 1 A Q a q
0 0 1 0 2 " 2 B R b r
0 0 1 1 3 # 3 C S c s
0 1 0 0 4 $ 4 D T d t
0 1 0 1 5 % 5 E U e u
0 1 1 0 6 & 6 F V f v
0 1 1 1 7 ' 7 G W g w
1 0 0 0 8 ( 8 H X h x
1 0 0 1 9 ) 9 I Y i y
1 0 1 0 A * : J Z j z
1 0 1 1 B + ; K [ k {
1 1 0 0 C , < L ¥ l |
1 1 0 1 D - = M ] m }
1 1 1 0 E . > N ^ n ~
1 1 1 1 F / ? O _ o DEL

GS1 DataMatrix (ECC200) can specify from 00H to FFH except for printer control code of 05H, 10H, 11H, 18H, 1BH.

When specifying 7EH, specify [7EH, 7EH].