[ESC+FX] DataMatrix (ECC200) Sequential Number (Compatible Command)
Hexadecimal code
| ESC | <1B>16 |
|---|---|
| FX | <46>16<58>16 |
Parameter
aaabcccdddeee
Initial value
Nil
Valid range and term of command
| When the power switch is OFF | The set parameter is not maintained. |
| Valid range within items | The set parameter becomes invalid. |
| Valid range between items | The set parameter becomes invalid. |
Function
Specifying sequential number for DataMatrix.
Format (Sequential number part)
<FX>aaabcccdddeee
-
Parameter
a [Number of duplication to print] = Valid Range : 001 to 999
b [Flag of increase and decrease]
= + : Increment
= - : Decrement
c [Number of increase and decrease] = Valid Range : 001 to 999
d [Specification of digit position] = Valid Range : 001 to 999
e [Number of digit] = Valid Range : 001 to 999
Coding Example
Number of duplication to print: 001, Flag of increase and decrease: +, Number of increase and decrease: 001, Digit position: 005, Number of digit: 003
<A>
<V>100<H>200
<FX>001+001005003
<BX>01100202000000001
<DC>00006000
<Q>2
<Z>
Supplementary explanation per model: PW2 series
- Support only PW208NX/PW208mNX (International).
Precautions during use
- This is the command of the old specification. Recommend the use of <2D50>.
GS1 DataMatrix (ECC200) Code table (<DC>)
| SI | SO | |||||||||||||||||||
| B8 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | ||||
| B7 | 0 | 0 | 0 | 0 | 1 | 1 | 1 | 1 | 0 | 0 | 0 | 0 | 1 | 1 | 1 | 1 | ||||
| B6 | 0 | 0 | 1 | 1 | 0 | 0 | 1 | 1 | 0 | 0 | 1 | 1 | 0 | 0 | 1 | 1 | ||||
| B5 | 0 | 1 | 0 | 1 | 0 | 1 | 0 | 1 | 0 | 1 | 0 | 1 | 0 | 1 | 0 | 1 | ||||
| B4 | B3 | B2 | B1 | 0 | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | A | B | C | D | E | F | |
| 0 | 0 | 0 | 0 | 0 | SP | 0 | @ | P | ` | p | ||||||||||
| 0 | 0 | 0 | 1 | 1 | ! | 1 | A | Q | a | q | ||||||||||
| 0 | 0 | 1 | 0 | 2 | " | 2 | B | R | b | r | ||||||||||
| 0 | 0 | 1 | 1 | 3 | # | 3 | C | S | c | s | ||||||||||
| 0 | 1 | 0 | 0 | 4 | $ | 4 | D | T | d | t | ||||||||||
| 0 | 1 | 0 | 1 | 5 | % | 5 | E | U | e | u | ||||||||||
| 0 | 1 | 1 | 0 | 6 | & | 6 | F | V | f | v | ||||||||||
| 0 | 1 | 1 | 1 | 7 | ' | 7 | G | W | g | w | ||||||||||
| 1 | 0 | 0 | 0 | 8 | ( | 8 | H | X | h | x | ||||||||||
| 1 | 0 | 0 | 1 | 9 | ) | 9 | I | Y | i | y | ||||||||||
| 1 | 0 | 1 | 0 | A | * | : | J | Z | j | z | ||||||||||
| 1 | 0 | 1 | 1 | B | + | ; | K | [ | k | { | ||||||||||
| 1 | 1 | 0 | 0 | C | , | < | L | ¥ | l | | | ||||||||||
| 1 | 1 | 0 | 1 | D | - | = | M | ] | m | } | ||||||||||
| 1 | 1 | 1 | 0 | E | . | > | N | ^ | n | ~ | ||||||||||
| 1 | 1 | 1 | 1 | F | / | ? | O | _ | o | DEL | ||||||||||
GS1 DataMatrix (ECC200) can specify from 00H to FFH except for printer control code of 05H, 10H, 11H, 18H, 1BH.
When specifying 7EH, specify [7EH, 7EH].