[ESC+*] Memory Clear
CL4NX
CL6NX
CL4NX-J
CL6NX-J
PW208/PW208m
PW208NX/PW208mNX
FX3-LX
CT4-LX/HC4-LX
PW4NX
LR4NX-FA
S84NX/S86NX
CL4-SXR
CL6-SXR
Hexadecimal code
| ESC | <1B>16 |
|---|---|
| * | <2A>16 |
Parameter
a
Initial value
Nil
Valid range and term of command
| When the power switch is OFF | The set parameter is not maintained. |
| Valid range within items | The set parameter becomes invalid. |
| Valid range between items | The set parameter becomes invalid. |
Function
Clears print jobs and specific item in memory.
Format
<*>a
- Parameter
a [Item to be cleared]
= Not specified:
Single item buffer, Receive buffer, Edit buffer (reprint is not possible)
Multi item buffer, Receive buffer, Edit buffer (Clears job in parsing)
= T : User defined characters
= & : Form overlay
= X : All clear
(Receive buffer, Edit buffer, User defined characters, form overlay)
Note the job, which is currently in progress, will not be cleared
Coding Example 1
Clear receive and edit buffer
<A>
<*>
<Z>
Coding Example 2
All clear
<A>
<*>X
<Z>
Coding Example 3
Clear user-defined characters <A>
<A>
<*>T
<Z>
Supplementary Explanation
【CL4-SXR/CL6-SXR】
- Set this command between Start code<A> and Stop code<Z>.
- This command<*> (a=X) will clear all the data sent before the command. However, the data which is currently in progress will not be cleared. X will also clear user-defined characters and form overlay.
【Other Printer】
- Set this command between Start code<A> and Stop code<Z>.
- This command<*> (a=X) will clear all the data sent before the command. However, the data which is completely parsed before the command will not be cleared. X will also clear user-defined characters and form overlay.
Note
- After the command <*> is executed, have an interval of more than 100ms before sending next print data.
- The job in printing will not be terminated by the command <*>.