[ESC+CL] Delete CR/LF

CL4NX CL6NX CL4NX-J CL6NX-J PW208/PW208m PW208NX/PW208mNX FX3-LX CT4-LX/HC4-LX PW4NX LR4NX-FA S84NX/S86NX CL4-SXR CL6-SXR

Hexadecimal code

ESC <1B>16
CL <50>16<4D>16

Parameter

a

Initial value

Nil

Valid range and term of command

When the power switch is OFF The set parameter is maintained.
Valid range within items The set parameter is valid until the next valid setting.
Valid range between items The set parameter is valid until the next valid setting.

Function

Deletes CR/LF included in print commands.

Format

<CL>a

  • Parameter

    a [Delete CR/LF]

    = 0: Do not delete CR/LF

    = 1: Deletes CR/LF

Coding Example


<A>
<CL>1
<Z>
                    

Supplementary Explanation

  1. Delimit Start of Data Transmission <A> and End of Data Transmission <Z> with this command for use.
  2. This command cannot be used in combination with other commands.