[ESC+ES] Completion Quantity of Application
CL4NX
CL6NX
CL4NX-J
CL6NX-J
PW208/PW208m
PW208NX/PW208mNX
FX3-LX
CT4-LX/HC4-LX
PW4NX
LR4NX-FA
S84NX/S86NX
CL4-SXR
CL6-SXR
Hexadecimal code
| ESC | <1B>16 |
|---|---|
| ES | <45>16<53>16 |
Parameter
aaaaaa
Initial value
Nil
Function
Setting the completion quantity of application in the ENQ response status to the set value.
When the total print count is displayed on the screen, the specified value is set as the total print count.
Format
<ES>aaaaaa
- Parameter
aaaaaa [Completion Quantity of Application] = Valid Range: 000000 to 999999
Coding Example
Completion Quantity of Application: 123456
<A>
<ES>123456
<Z>
Supplementary Explanation
- This command is provided only for returning the statusL and cannot be used with other protocols.
- Do not send this command during printing or application. (If there are unprocessed print data, do not send this command.)
- Do not send to the command statement (STX - ETX) a command other than the completion quantity of application [ESC+ES] setting command.