[ESC+FR] Paper Type
CL4NX
CL6NX
CL4NX-J
CL6NX-J
PW208/PW208m
PW208NX/PW208mNX
FX3-LX
CT4-LX/HC4-LX
PW4NX
LR4NX-FA
S84NX/S86NX
CL4-SXR
CL6-SXR
Hexadecimal code
| ESC | <1B>16 |
|---|---|
| FR | <46>16<52>16 |
Parameter
a
Initial value
a=0
Valid range and term of command
| When the power switch is OFF | The set parameter is maintained. |
| Valid range within items | The set parameter becomes invalid. |
| Valid range between items | The set parameter becomes invalid. |
Function
Specify paper type
Format
<FR>a
- Parameter
a [Paper type]
= 6: Barlabe fix label (M32 label)
= 7: Barlabe free label (HT label)
= 8: Petit Lapin label
Coding example
<A>
<FR>7
<Z>
Supplementary Explanation
- Printer print labels after feeding 1 label automatically when printer receives the request for the first print if paper type is changed with <FR>. Please note that there will be no auto feed when printer feeds label after feed key is pressed on offline screen.
- Please make sure to use A1 command to specify the size of paper for specifying [6. Barlabe fix label (M32 label)].
a "Vertical Label Size" of A1 command should be 16mm/20mm/25mm/35mm/38mm. If any other size is specified, a print skip error will occur. - If parameter specified is out of range, it does not return a command error. In this case the command becomes invalid and retains the current settings. However if the non-numeric value is specified in the parameter, a command error is returned.