[ESC+FR] Paper Type

CL4NX CL6NX CL4NX-J CL6NX-J PW208/PW208m PW208NX/PW208mNX FX3-LX CT4-LX/HC4-LX PW4NX LR4NX-FA S84NX/S86NX CL4-SXR CL6-SXR

Hexadecimal code

ESC <1B>16
FR <46>16<52>16

Parameter

a

Initial value

a=0

Valid range and term of command

When the power switch is OFF The set parameter is maintained.
Valid range within items The set parameter becomes invalid.
Valid range between items The set parameter becomes invalid.

Function

Specify paper type

Format

<FR>a

  • Parameter

    a [Paper type]

    = 6: Barlabe fix label (M32 label)

    = 7: Barlabe free label (HT label)

    = 8: Petit Lapin label

Coding example


<A>
<FR>7
<Z>
                    

Supplementary Explanation

  1. Printer print labels after feeding 1 label automatically when printer receives the request for the first print if paper type is changed with <FR>. Please note that there will be no auto feed when printer feeds label after feed key is pressed on offline screen.
  2. Please make sure to use A1 command to specify the size of paper for specifying [6. Barlabe fix label (M32 label)].
    a "Vertical Label Size" of A1 command should be 16mm/20mm/25mm/35mm/38mm. If any other size is specified, a print skip error will occur.
  3. If parameter specified is out of range, it does not return a command error. In this case the command becomes invalid and retains the current settings. However if the non-numeric value is specified in the parameter, a command error is returned.