[ESC+#] Base Reference Point

CL4NX CL6NX CL4NX-J CL6NX-J PW208/PW208m PW208NX/PW208mNX FX3-LX CT4-LX/HC4-LX PW4NX LR4NX-FA S84NX CL4-SXR CL6-SXR

Hexadecimal code

ESC <1B>16
# <23>16

Parameter

(a)bbb

Initial value

Nil

Valid range and term of command

When the power switch is OFF The set parameter is maintained.
Valid range within items The set parameter becomes valid until next specification is made.
Valid range between items The set parameter becomes valid until next specification is made.

Function

Specify the base reference point in vertical direction.

Format

<#>(a)bbb

  • Parameter

    a "Moving Direction"

    = +: Feed Direction (If parameter [a] is omitted, the value is +)

    = -: Reverse Direction

    b "Distance in dots"

    = Valid range of CL4NX/CL4NX-J/S84NX: 000 to 600 (in dots)

    = Valid range of CL4-SXR/CL6-SXR(I-mark Sensor): 000 to 182 (203dpi), 000 to 237 (305dpi), 000 to 600 (609dpi) (in dots)

    = Valid range of CL4-SXR/CL6-SXR(Gap Sensor): 000 to 494 (203dpi), 000 to 600 (305dpi), 000 to 600 (609dpi) (in dots)

    = Valid range of CT4-LX/HC4-LX: 000 to 200 (in dots)

Coding Example of CL4NX/CL4NX-J/S84NX/CL4-SXR/CL6-SXR


<A>
<#>+040
<Z>
                    

Coding Example of CT4-LX/HC4-LX


<A>
<#>+150
<Z>
                    

Supplemental explanation of CL4NX/CL6NX/CL4NX-J/CL6NX-J/S84NX/CL4-SXR/CL6-SXR

  1. Initial value of the reference position is 0 dot.
  2. The position specified with <#> command is a start position that measures Y value described in "Inlay Configuration Guide".
  3. When parameter "a" "Moving direction" = "+: Feed Direction", do not specify 25 mm or more in total with other adjust print position value. If it is set to 25 mm or more, sometimes it does not stop properly.
  4. This command is for correction of RFID encoding position. Thus, control to prevent drop-off of the cutter causes the encoding position to be invalid. So it is outside the scope of correction. (excluding S84NX)
  5. Specifying a value within the valid range for parameter [bbb] and entering [0] before that value will not result in a command error.

    Example: <#>+00000200 -> 200 dots is reflected.

Supplemental explanation of CT4-LX/HC4-LX

  1. Please use it limited to the RFID specification. Used to correct the RFID encoding position.
  2. Initial value of the reference position is 0 dot.
  3. The print start position from the label end needs to change the base point correction <A3>, print vertical position specification <V>, and paper size specification <A1>.
  4. This command is provided to correct the RFID encoding position. Therefore, the control for preventing the cutter from falling off makes the encoding position incorrect, so it is not subject to correction.
  5. Specifying a value within the valid range for parameter [bbb] and entering [0] before that value will not result in a command error.

    Example: <#>+00000200 -> 200 dots is reflected.