[ESC+#E] Print Darkness (Compatible Command)

CL4NX CL6NX CL4NX-J CL6NX-J PW208/PW208m PW208NX/PW208mNX FX3-LX CT4-LX/HC4-LX PW4NX LR4NX-FA S84NX/S86NX CL4-SXR CL6-SXR

Hexadecimal code

ESC <1B>16
#E <23>16<45>16

Parameter

ab

Initial value

Nil

Valid range and term of command

When the power switch is OFF The set parameter is maintained.
Valid range within items The set parameter is valid until the next valid setting.
Valid range between items The set parameter is valid until the next valid setting.

Function

Specifies print darkness.

Format

<#E>ab

  • Parameter

    a [Print darkness level specification] = 1 to 5

    1: Lightest ↔ 5: Darkest

    b [Print darkness specification] = A to F (omissible)

    This parameter is usually "A".

    The parameter valid range differs depending on the model. (See the table below)

Coding Example


<A>
<#E>3A
<Z>
                    

Supplementary Explanation

Print darkness value specified by the command.

Note

  1. This command is for the compatibility with previous one. The print darkness level obtained by DC2+PB, and the print darkness level on the display screen becomes twice the value set by this command.

    (CL4NX/CL4NX-J, PW208/PW208m, PW208NX/PW208mNX, FX3-LX, CT4-LX/HC4-LX, PW4NX, CL4-SXR)

  2. Darkness levels 1, 2 and 3 will be 1, 5 and 10 each in CL6NX/CL6NX-J, CL6-SXR.

Print darkness level range

Model Parameter valid range When setting outside of valid range
CL4NX
CL4NX-J
203 dpi 1 to 5

Command error will occur when other values than parameter valid range in the left is specified.

305 dpi 1 to 5
609 dpi 1 to 5
CL6NX
CL6NX-J
203 dpi 1 to 3

Command error will occur.

However it will work as 2 for 305 dpi when 4 or 5 is specified.

305 dpi 1 to 3
PW208
PW208NX/PW208mNX
203 dpi 1 to 5

Command error will occur when other values than parameter valid range in the left is specified.

FX3-LX 305 dpi 1 to 5

Command error will occur when other values than parameter valid range in the left is specified.

CT4-LX
HC4-LX
203 dpi 1 to 5

Command error will occur when other values than parameter valid range in the left is specified.

305 dpi 1 to 5
PW4NX 203 dpi 1 to 5

Command error will occur when other values than parameter valid range in the left is specified.

LR4NX-FA 203 dpi 1 to 3

Command error will occur.

However it will work as 2 for 305 dpi or 609 dpi when 4 or 5 is specified.

305 dpi 1 to 5
609 dpi 1 to 3
S84NX/S86NX

SBPL > Compatible > Darkness

M8485/90/60/65Se

1 to 3

Command error will occur when other values than parameter valid range in the left is specified.

SBPL > Compatible > Darkness

S84/M8459Se

1 to 5

Command error will occur when other values than parameter valid range in the left is specified.

CL4-SXR 203 dpi 1 to 5

Command error will occur when other values than parameter valid range in the left is specified.

305 dpi 1 to 5
609 dpi 1 to 5
CL6-SXR 203 dpi 1 to 3

Command error will occur when other values than parameter valid range in the left is specified. However, it will work as 2 for 305 dpi when 4 or 5 is specified.

305 dpi 1 to 3

Print darkness range

Model Parameter valid range When setting outside of valid range
CL4NX/CL4NX-J
CL6NX/CL6NX-J
PW208/PW208m
PW208NX/PW208mNX
FX3-LX
CT4-LX/HC4-LX
PW4NX
LR4NX-FA
S84NX/S86NX
CL4-SXR
CL6-SXR
A

From B to F are reserved. The same darkness as A.

Print darkness other than from A to F will be replaced with A. (It doesn't become a command error.)

Additional explanation for CL4NX/CL4NX-J

  1. This command is for compatibility. The print darkness level acquired with DC2+PB and the print darkness level displayed on GUI will be twice as much as the value set with this command.

Additional explanation for CL6NX/CL6NX-J

  1. Darkness levels 1, 2 and 3 will be 1, 5 and 10 each in CL6NX.

Additional explanation: PW2 series, PW4NX

  1. This command is for compatibility. The print darkness level acquired with DC2+PB and the print darkness level displayed on GUI will be twice as much as the value set with this command.

Additional explanation: FX3-LX series

  1. This command is for compatibility. The print darkness level acquired with DC2+PB and the print darkness level displayed on GUI will be twice as much as the value set with this command.

Additional explanation: CT4-LX/HC4-LX series

  1. This command is for compatibility. The print darkness level acquired with DC2+PB and the print darkness level displayed on GUI will be twice as much as the value set with this command.

Additional explanation: S84NX/S86NX

  1. This command is for compatibility.
  2. If print darkness compatibility setting is "Disabled", this command will be ignored.
  3. If print darkness compatibility setting is set at "M8485/90/60/65Se", print density level acquired by DC2+PB and print density level shown in the screen will be three times the selected value of this command.
  4. If print darkness compatibility setting is set at"S84/M8459Se", print density level acquired by DC2+PB and print density level shown in the screen will be two times the selected value of this command.
  5. A is the only valid parameter range for print darkness selection; B to F will be ignored.

Additional explanation: CL4-SXR

  1. This command is for compatibility. The print darkness level acquired with DC2+PB and the print darkness level displayed on GUI will be twice as much as the value set with this command.

Additional explanation: CL6-SXR

  1. When the print darkness level is 1, 2 and 3, it will be 1, 5 and 10 respectively in CL6-SXR.