[ESC+#E] Print Darkness (Compatible Command)
Hexadecimal code
| ESC | <1B>16 |
|---|---|
| #E | <23>16<45>16 |
Parameter
ab
Initial value
Nil
Valid range and term of command
| When the power switch is OFF | The set parameter is maintained. |
| Valid range within items | The set parameter is valid until the next valid setting. |
| Valid range between items | The set parameter is valid until the next valid setting. |
Function
Specifies print darkness.
Format
<#E>ab
- Parameter
a [Print darkness level specification] = 1 to 5
1: Lightest ↔ 5: Darkest
b [Print darkness specification] = A to F (omissible)
This parameter is usually "A".
The parameter valid range differs depending on the model. (See the table below)
Coding Example
<A>
<#E>3A
<Z>
Supplementary Explanation
Print darkness value specified by the command.
Note
-
This command is for the compatibility with previous one. The print darkness level obtained by DC2+PB, and the print darkness level on the display screen becomes twice the value set by this command.
(CL4NX/CL4NX-J, PW208/PW208m, PW208NX/PW208mNX, FX3-LX, CT4-LX/HC4-LX, PW4NX, CL4-SXR)
- Darkness levels 1, 2 and 3 will be 1, 5 and 10 each in CL6NX/CL6NX-J, CL6-SXR.
Print darkness level range
| Model | Parameter valid range | When setting outside of valid range | |
|---|---|---|---|
|
CL4NX CL4NX-J |
203 dpi | 1 to 5 |
Command error will occur when other values than parameter valid range in the left is specified. |
| 305 dpi | 1 to 5 | ||
| 609 dpi | 1 to 5 | ||
|
CL6NX CL6NX-J |
203 dpi | 1 to 3 |
Command error will occur. However it will work as 2 for 305 dpi when 4 or 5 is specified. |
| 305 dpi | 1 to 3 | ||
|
PW208 PW208NX/PW208mNX |
203 dpi | 1 to 5 |
Command error will occur when other values than parameter valid range in the left is specified. |
| FX3-LX | 305 dpi | 1 to 5 |
Command error will occur when other values than parameter valid range in the left is specified. |
|
CT4-LX HC4-LX |
203 dpi | 1 to 5 |
Command error will occur when other values than parameter valid range in the left is specified. |
| 305 dpi | 1 to 5 | ||
| PW4NX | 203 dpi | 1 to 5 |
Command error will occur when other values than parameter valid range in the left is specified. |
| LR4NX-FA | 203 dpi | 1 to 3 |
Command error will occur. However it will work as 2 for 305 dpi or 609 dpi when 4 or 5 is specified. |
| 305 dpi | 1 to 5 | ||
| 609 dpi | 1 to 3 | ||
| S84NX/S86NX |
SBPL > Compatible > Darkness M8485/90/60/65Se |
1 to 3 |
Command error will occur when other values than parameter valid range in the left is specified. |
|
SBPL > Compatible > Darkness S84/M8459Se |
1 to 5 |
Command error will occur when other values than parameter valid range in the left is specified. |
|
| CL4-SXR | 203 dpi | 1 to 5 |
Command error will occur when other values than parameter valid range in the left is specified. |
| 305 dpi | 1 to 5 | ||
| 609 dpi | 1 to 5 | ||
| CL6-SXR | 203 dpi | 1 to 3 |
Command error will occur when other values than parameter valid range in the left is specified. However, it will work as 2 for 305 dpi when 4 or 5 is specified. |
| 305 dpi | 1 to 3 | ||
Print darkness range
| Model | Parameter valid range | When setting outside of valid range |
|---|---|---|
|
CL4NX/CL4NX-J CL6NX/CL6NX-J PW208/PW208m PW208NX/PW208mNX FX3-LX CT4-LX/HC4-LX PW4NX LR4NX-FA S84NX/S86NX CL4-SXR CL6-SXR |
A |
From B to F are reserved. The same darkness as A. Print darkness other than from A to F will be replaced with A. (It doesn't become a command error.) |
Additional explanation for CL4NX/CL4NX-J
- This command is for compatibility. The print darkness level acquired with DC2+PB and the print darkness level displayed on GUI will be twice as much as the value set with this command.
Additional explanation for CL6NX/CL6NX-J
- Darkness levels 1, 2 and 3 will be 1, 5 and 10 each in CL6NX.
Additional explanation: PW2 series, PW4NX
- This command is for compatibility. The print darkness level acquired with DC2+PB and the print darkness level displayed on GUI will be twice as much as the value set with this command.
Additional explanation: FX3-LX series
- This command is for compatibility. The print darkness level acquired with DC2+PB and the print darkness level displayed on GUI will be twice as much as the value set with this command.
Additional explanation: CT4-LX/HC4-LX series
- This command is for compatibility. The print darkness level acquired with DC2+PB and the print darkness level displayed on GUI will be twice as much as the value set with this command.
Additional explanation: S84NX/S86NX
- This command is for compatibility.
- If print darkness compatibility setting is "Disabled", this command will be ignored.
- If print darkness compatibility setting is set at "M8485/90/60/65Se", print density level acquired by DC2+PB and print density level shown in the screen will be three times the selected value of this command.
- If print darkness compatibility setting is set at"S84/M8459Se", print density level acquired by DC2+PB and print density level shown in the screen will be two times the selected value of this command.
- A is the only valid parameter range for print darkness selection; B to F will be ignored.
Additional explanation: CL4-SXR
- This command is for compatibility. The print darkness level acquired with DC2+PB and the print darkness level displayed on GUI will be twice as much as the value set with this command.
Additional explanation: CL6-SXR
- When the print darkness level is 1, 2 and 3, it will be 1, 5 and 10 respectively in CL6-SXR.