[ESC+#F] Print Darkness
CL4NX
CL6NX
CL4NX-J
CL6NX-J
PW208/PW208m
PW208NX/PW208mNX
FX3-LX
CT4-LX/HC4-LX
PW4NX
LR4NX-FA
S84NX/S86NX
CL4-SXR
CL6-SXR
Hexadecimal code
| ESC | <1B>16 |
|---|---|
| #F | <23>16<46>16 |
Parameter
ab or aab
Initial value
Refer to the table below.
Valid range and term of command
| When the power switch is OFF | The set parameter is maintained. |
| Valid range within items | The set parameter is valid until the next valid setting. |
| Valid range between items | The set parameter is valid until the next valid setting. |
Function
Specifies print darkness.
Format
<#F>ab
<#F>aab
- Parameter
a [Print darkness level specification] = 1 to 10
1: Lightest ↔ 10: Darkest
b [Print darkness specification] = A to F (omissible)
This parameter is usually "A".
The parameter valid range differs depending on the model. (See the table below)
Coding Example
<A>
<#F>5A
<Z>
Supplementary Explanation
Print darkness value specified by the command or LCD is maintained.
Note
- If the value over valid range is specified, command error will occur and print darkness will not be changed.
- Initial value is settable by default setting operation of the printer.
Print darkness level range
| Model | Default | Parameter valid range | When setting outside of valid range |
|---|---|---|---|
|
CL4NX/CL4NX-J CL6NX/CL6NX-J PW208/PW208m PW208NX/PW208mNX FX3-LX CT4-LX/HC4-LX PW4NX LR4NX-FA CL4-SXR CL6-SXR |
5 | 1 to 10 | Command error will occur when other values than parameter valid range in the left is specified. |
| S84NX/S86NX | 6 | 1 to 10 | Command error will occur when other values than parameter valid range in the left is specified. |
Print darkness range
| Model | Default | Parameter valid range | When setting outside of valid range |
|---|---|---|---|
|
CL4NX/CL4NX-J CL6NX/CL6NX-J PW208/PW208m PW208NX/PW208mNX FX3-LX CT4-LX/HC4-LX PW4NX LR4NX-FA S84NX/S86NX CL4-SXR CL6-SXR |
A | A |
From B to F are reserved. The same darkness as A. For international models: Print darkness other than from A to F will be replaced with A. (It doesn't become a command error.) |
Supplementary explanation: S84NX/S86NX
- "A" is the only valid parameter range for print darkness selection; "B" to "F" will be ignored.