[ESC+#F] Print Darkness

CL4NX CL6NX CL4NX-J CL6NX-J PW208/PW208m PW208NX/PW208mNX FX3-LX CT4-LX/HC4-LX PW4NX LR4NX-FA S84NX/S86NX CL4-SXR CL6-SXR

Hexadecimal code

ESC <1B>16
#F <23>16<46>16

Parameter

ab or aab

Initial value

Refer to the table below.

Valid range and term of command

When the power switch is OFF The set parameter is maintained.
Valid range within items The set parameter is valid until the next valid setting.
Valid range between items The set parameter is valid until the next valid setting.

Function

Specifies print darkness.

Format

<#F>ab

<#F>aab

  • Parameter

    a [Print darkness level specification] = 1 to 10

    1: Lightest ↔ 10: Darkest

    b [Print darkness specification] = A to F (omissible)

    This parameter is usually "A".

    The parameter valid range differs depending on the model. (See the table below)

Coding Example


<A>
<#F>5A
<Z>
                    

Supplementary Explanation

Print darkness value specified by the command or LCD is maintained.

Note

  1. If the value over valid range is specified, command error will occur and print darkness will not be changed.
  2. Initial value is settable by default setting operation of the printer.

Print darkness level range

Model Default Parameter valid range When setting outside of valid range
CL4NX/CL4NX-J
CL6NX/CL6NX-J
PW208/PW208m
PW208NX/PW208mNX
FX3-LX
CT4-LX/HC4-LX
PW4NX
LR4NX-FA
CL4-SXR
CL6-SXR
5 1 to 10 Command error will occur when other values than parameter valid range in the left is specified.
S84NX/S86NX 6 1 to 10 Command error will occur when other values than parameter valid range in the left is specified.

Print darkness range

Model Default Parameter valid range When setting outside of valid range
CL4NX/CL4NX-J
CL6NX/CL6NX-J
PW208/PW208m
PW208NX/PW208mNX
FX3-LX
CT4-LX/HC4-LX
PW4NX
LR4NX-FA
S84NX/S86NX
CL4-SXR
CL6-SXR
A A

From B to F are reserved. The same darkness as A.


For international models:

Print darkness other than from A to F will be replaced with A. (It doesn't become a command error.)

Supplementary explanation: S84NX/S86NX

  1. "A" is the only valid parameter range for print darkness selection; "B" to "F" will be ignored.