[ESC+HL] Item Signal

CL4NX CL6NX CL4NX-J CL6NX-J PW208/PW208m PW208NX/PW208mNX FX3-LX CT4-LX/HC4-LX PW4NX LR4NX-FA S84NX/S86NX CL4-SXR CL6-SXR

Hexadecimal code

ESC <1B>16
HL <48>16<4C>16

Parameter

a

Initial value

Nil

Valid range and term of command

When the power switch is OFF The set command is not maintained.
Valid range within items The set parameter becomes invalid.
Valid range between items The set parameter becomes invalid.

Function

Specifying the output status of the item signal (external output signal) when outputting the Apply Ready signal (external output signal).

Format

<HL>a

  • Parameter

    a [Work]

    = 0: Low (Output Lo)

    = 1: High (Output Hi)

Coding Example

Work: High


<A>
<HL>1
<V>100<H>200<P>02<L>0202<X22>ABCD
<Z>
                    

Supplementary Explanation

  1. This command is provided only for returning the statusL and cannot be used with other protocols.
  2. If this command is not specified, "Low" is assumed.