[ESC+HL] Item Signal
CL4NX
CL6NX
CL4NX-J
CL6NX-J
PW208/PW208m
PW208NX/PW208mNX
FX3-LX
CT4-LX/HC4-LX
PW4NX
LR4NX-FA
S84NX/S86NX
CL4-SXR
CL6-SXR
Hexadecimal code
| ESC | <1B>16 |
|---|---|
| HL | <48>16<4C>16 |
Parameter
a
Initial value
Nil
Valid range and term of command
| When the power switch is OFF | The set command is not maintained. |
| Valid range within items | The set parameter becomes invalid. |
| Valid range between items | The set parameter becomes invalid. |
Function
Specifying the output status of the item signal (external output signal) when outputting the Apply Ready signal (external output signal).
Format
<HL>a
- Parameter
a [Work]
= 0: Low (Output Lo)
= 1: High (Output Hi)
Coding Example
Work: High
<A>
<HL>1
<V>100<H>200<P>02<L>0202<X22>ABCD
<Z>
Supplementary Explanation
- This command is provided only for returning the statusL and cannot be used with other protocols.
- If this command is not specified, "Low" is assumed.