[ESC+PA] Pass-through
Hexadecimal code
| ESC | <1B>16 |
|---|---|
| PA | <50>16<41>16 |
Parameter
aaaaaa
Initial value
Nil
Valid range and term of command
| When the power switch is OFF | The set command is not maintained. |
| Valid range within items | The set parameter becomes invalid. |
| Valid range between items | The set parameter becomes invalid. |
Function
Letting application target objects pass without label being applied for the specified number of times.
Format
<PA>aaaaaa
- Parameter
aaaaaa [Number of pass] = Valid Range: 000001 to 999999
Coding Example
Number of pass: 10
<A>
<PA>000010
<Z>
Supplementary Explanation
-
When the target objects have passed, the completion quantity of application in the status information (status for the ENQ request) is incremented. (Only with the protocol of statusL)
-
Do not send to the command statement (STX - ETX) a command other than the pass command.
(Job ID number specification <ID> and job name specification <WK> are available.)
-
This command is processed only when the product is online.
If an error occurs during the object passing processing and then when the online mode is activated after the error is cleared, the operation resumes with the pass processing that have not been completed. Activation signals during the error are ignored. During the offline mode, when an applying start signal is input as the Activate Apply signal, an error occurs, or when Input as the Activate Apply (Level) signal, the signal is ignored.
Note
-
During the command processing (passing), "PASS" is displayed on the normal "QTY" display area on the LCD screen.