[ESC+PG] Designation of Registration on Printer Motion
Hexadecimal code
| ESC | <1B>16 |
|---|---|
| PG | <50>16<47>16 |
Parameter
abcdefghiiiijjjjkkkkllllmmmnnnooopppqrs
Initial value
Refer to the table below
Valid range and term of command
| When the power switch is OFF | The set parameter is not maintained. |
| Valid range within items | The set parameter is valid until the next valid setting. |
| Valid range between items | The set parameter is valid until the next valid setting. |
Function
Gives offset to media's stop position on the fly.
Format
<PG>Abcdefghiiiijjjjkkkkllllmmmnnnooopppqrs
- Parameter
Using ASCII code for parameter. For the detailed parameter, refer to the table below.
Coding Example
<A>
<PG><33 33 41 31 30 31 30 30 31 32 38 30 30 33 38 34 2B 30 30 31 2B 30 30
31 2B 30 30 2B 30 30 2B 30 30 30 30 30 30 30 30>16
<Z>
Describing parameter value in ASCII code.
<30H>16<30H>16<2H>16・・・・・・ <00H>16
Supplementary Explanation
- This command is not necessary in the normal label printing operation.
- Operation settings specified with this command are still in effect after turning off the printer.
- The same setting are accessible from the printer setting tool.
Note
- This command is for old specification. Please use Language Common Command DC2+PA.
- It is required to validate PT compatible setting (COMP_PT_PG) at [SBPL] section of Language Common Command DC2+PA to use this command.
Parameter
| No | Item | Explanation | Digit number | Remarks |
|---|---|---|---|---|
| a | Print speed |
1: Max. 75mm/sec 2: Max. 103mm/sec |
1 | |
| b | Print darkness level |
1: Lightest 2: Light 3: Normal 4: Dark 5: Darkest |
1 | *1 |
| c | Print darkness range | A - C | 1 | *1 |
| d | Backfeed (Dispenser) |
1: Motion 1 (Head position) 2: Motion 2 (Dispensing position) 3: No backfeed |
1 | |
| Backfeed (Linerless) |
1: Head position, no initial paper feed movement 2: Head position, with initial paper feed movement 3: No backfeed, no initial paper feed movement |
*2 | ||
| e | Zero slash |
0: Disable 1: Enable |
1 | |
| f | Kanji code |
0: JIS code 1: Shift JIS code |
1 | |
| g | Initial feed |
0: Disable 1: Enable |
1 | |
| h | Proportional pitch |
0: Release of proportional pitch 1: Designation of proportional pitch |
1 | |
| i | Height of label | 0001 to 1280 dots | 4 | |
| j | Width of label | 0001 to 0384 dots (4 digits) | 4 | |
| k | Vertical start point correction |
1st digit: +, - (4 digits) 2nd to 4th digit: 000 to 300 |
4 | |
| l | Horizontal start point correction |
1st digit: +, - (4 digits) 2nd to 4th digit: 000 to 300 |
4 | |
| m | Label pitch offset |
1st digit: +, - (3 digits) 2nd to 4th digit: 00 to 99 |
3 | *3 |
| n | Tear-off offset |
1st digit: +, - (3 digits) 2nd to 4th digit: 00 to 99 |
3 | *3 |
| o | Dispenser offset |
1st digit: +, - (3 digits) 2nd to 4th digit: 00 to 99 |
3 | *3 |
| p | Auto power off |
000: No auto power off (3 digits) 001 to 999 minutes |
3 | |
| q | Print mode |
0: Label printing mode (1 digit) 1: Journal printing mode (mode 1) 2: Dual-color Label printing mode 3: Dual-color Journal printing mode 4: Linerless label printing mode (mode 1) 5: Journal printing mode (mode 2) 6: Linerless label printing mode (mode 2) |
1 | *4 *5 |
| r | Print operation mode |
0: Tear-off (1 digit) 1: Continuous |
1 | *5 |
| s | Sensor type |
0: Reflective sensor (I-mark) (1 digit) 1: See-through sensor (Gap) |
1 | *5 *6 |
- The darkness level will be twice as what was set. For darkness, A will be applied for specifying
either A, B or C.
Value set with <PG> Value in PW2 1A, 1B, 1C 2A 2A, 2B, 2C 4A 3A, 3B, 3C 6A 4A, 4B, 4C 8A 5A, 5B, 5C 10A - The linerless behavior in PW2 will be limited only to "Head position, no initial feed movement". Therefore, the printer works as "1: Head position, no initial feed movement" even if "2: Head position, with initial feed movement" or "3: No backfeed, no initial feed movement" are set.
- The following table explains the behavior of each offset. (range of PT208e)
Range of PT 208 (dots)
Valid range with <PG>Range of PW208/PW208m (dots) Label pitch offset -40 to 99 -90 to 99 Tear-off offset -99 to 99 -99 to 99 Dispenser offset -40 to 99 -20 to 99 Note: If a value below -20 is set in dispenser offset, it will be replaced with the minimum range of -20 for PW.
- Dual-color printing is out of specification for PW2. When you specify "2: Dual-color Label printing mode", the printer will work as "0: Label printing mode", and when you specify "3: Dual-color Journal printing mode" it will work as "1: Journal printing mode (mode 1)".
- The below is the table of combinations for the print mode, print operation mode and sensor type.
Configuration with <PG>:
q.Print modeConfiguration with <PG>:
r.Print operation modeConfiguration with <PG>:
s.Sensor typeBehavior of PW2 printer:
Print operationBehavior of PW2 printer:
Sensor type0: Print label
2: Dual-color Label printing
0: Tear-off 0: I-Mark sensor Tear-off I-Mark sensor 1: Gap sensor Gap sensor 1: Continuous 0: I-Mark sensor Continuous I-Mark sensor 1: Gap sensor Gap sensor 4: Linerless printing
5: Dual-color linerless printing
6: Linerless printing mode (Motion 2)
- - Linerless I-Mark sensor 1: Journal printing
3: Dual-color journal printing mode
0: Tear-off - Tear-off Sensor disabled 1: Continuous - Continuous Sensor disabled - The GAP sensor cannot be specified for PW208m/PW208mNX. The old value stays instead.