[ESC+PH] Print Method
CL4NX
CL6NX
CL4NX-J
CL6NX-J
PW208/PW208m
PW208NX/PW208mNX
FX3-LX
CT4-LX/HC4-LX
PW4NX
LR4NX-FA
S84NX/S86NX
CL4-SXR
CL6-SXR
Hexadecimal code
| ESC | <1B>16 |
|---|---|
| PH | <50>16<48>16 |
Parameter
a
Initial value
a=0
Valid range and term of command
| When the power switch is OFF | The set parameter is maintained. |
| Valid range within items | The set parameter is valid until the next valid setting. |
| Valid range between items | The set parameter is valid until the next valid setting. |
Function
Specifies print method.
Format
<PH>a
- Parameter
a [Print method]
= 0: Thermal transfer
= 1: Direct Thermal
Coding Example
<A>
<PH>0
<Z>
Supplementary Explanation
- Delimit Start of Data Transmission <A> and End of Data Transmission <Z> with this command for use.
- The set parameter is maintained after turning off the printer.
Supplementary explanation: S84NX/S86NX
- In case of using S84NX DT/S86NX DT (direct thermal printer) specification, the command will be ignored.