[ESC+~A] Cut Number Unit

CL4NX CL6NX CL4NX-J CL6NX-J PW208/PW208m PW208NX/PW208mNX FX3-LX CT4-LX/HC4-LX PW4NX LR4NX-FA S84NX/S86NX CL4-SXR CL6-SXR

Hexadecimal code

ESC <1B>16
~A <7E>16<41>16

Parameter

aaaa

Initial value

aaaa=1

Valid range and term of command

When the power switch is OFF The set parameter is not maintained.
Valid range within items The set parameter is valid until the next valid setting.
Valid range between items The set parameter becomes initial value at the next item <A>.

Function

Cuts labels at a specified interval in a print job.

Format

<~A>aaaa

  • Parameter

    a [Number of labels between each cut] = Valid range : 0 to 9999

Coding Example


<A>
<V>100<H>200<P>2<L>0202<XM>ABC
<~A>2
<Q>7
<Z>
                    

Supplementary Explanation

  1. Valid only for cutter models. Linerless models are not supported.
  2. If the parameter is not specified by this command <~A>, each label will be cut after being printed.
  3. In case the parameter "a" is set to 0, no label will be cut.
  4. Set this command before <Q> command.
  5. This command may not be used in combination with other cut commands <~>.