[ESC+~A] Cut Number Unit
CL4NX
CL6NX
CL4NX-J
CL6NX-J
PW208/PW208m
PW208NX/PW208mNX
FX3-LX
CT4-LX/HC4-LX
PW4NX
LR4NX-FA
S84NX/S86NX
CL4-SXR
CL6-SXR
Hexadecimal code
| ESC | <1B>16 |
|---|---|
| ~A | <7E>16<41>16 |
Parameter
aaaa
Initial value
aaaa=1
Valid range and term of command
| When the power switch is OFF | The set parameter is not maintained. |
| Valid range within items | The set parameter is valid until the next valid setting. |
| Valid range between items | The set parameter becomes initial value at the next item <A>. |
Function
Cuts labels at a specified interval in a print job.
Format
<~A>aaaa
- Parameter
a [Number of labels between each cut] = Valid range : 0 to 9999
Coding Example
<A>
<V>100<H>200<P>2<L>0202<XM>ABC
<~A>2
<Q>7
<Z>

Supplementary Explanation
- Valid only for cutter models. Linerless models are not supported.
- If the parameter is not specified by this command <~A>, each label will be cut after being printed.
- In case the parameter "a" is set to 0, no label will be cut.
- Set this command before <Q> command.
- This command may not be used in combination with other cut commands <~>.