[ESC+TW] Option Waiting Time

CL4NX CL6NX CL4NX-J CL6NX-J PW208/PW208m PW208NX/PW208mNX FX3-LX CT4-LX/HC4-LX PW4NX LR4NX-FA S84NX/S86NX CL4-SXR CL6-SXR

Hexadecimal code

ESC <1B>16
TW <54>16<57>16

Parameter

aaa

Initial value

aaa = 000

Valid range and term of command

When the power switch is OFF The set parameter is maintained.
Valid range within items The set parameter becomes invalid.
Valid range between items The set parameter becomes invalid.

Function

Specifies waiting time for optional device

Format

<TW>aaa

  • Parameter

    aaa [Waiting time] = Valid range: 000, 005 to 200 (unit: 100ms)

Coding Example

(waiting time = 1.5 seconds)


<A>
<TW>015
<Z>
                    

Supplementary Explanation

  1. This command specifies, in Tear-off mode, the waiting time between print completion and Tear-off motion.
  2. The set parameter becomes valid soon after receiving the command and will be retained after power off.

Supplementary Explanation per model: CT4-LX/HC4-LX series

  1. Only when the compatible setting "Option Wait Time Command" is enabled, the time specified by this command is also reflected in the partial cutter eject cut time.
    The specified parameters are converted and operated as shown in the table below.
    Parameter Wait time
    000 No eject cut
    005 - 014 1 [sec]
    015 - 024 2 [sec]
    025 - 034 3 [sec]
    035 - 044 4 [sec]
    045 - 200 5 [sec]