[ESC+VB] Barcode Checker

CL4NX CL6NX CL4NX-J CL6NX-J PW208/PW208m PW208NX/PW208mNX FX3-LX CT4-LX/HC4-LX PW4NX LR4NX-FA S84NX/S86NX CL4-SXR CL6-SXR

Hexadecimal code

ESC <1B>16
VB <56>16<42>16

Parameter

a,b,c,d,e,f,g

Initial value

Nil

Valid range and term of command

When the power switch is OFF The set parameter is maintained.
Valid range within items The set parameter becomes valid until next specification is made.
Valid range between items The set parameter becomes valid until next specification is made.

Function

A control command for barcode checker.

Format

<VB>a,b,c,d,e,f,g

  • Parameter

    a "Mode"

    = 0: Disabled

    = 1: Readable

    = 2: Comparison

    * When "Disabled" is specified, all the subsequent parameters will not function. *1

    b "Start Position"

    = 10-20000 dots (203 dpi)

    = 15-18000 dots (305 dpi)

    = 30-9600 dots (609 dpi)

    c "VOID print"

    = 0: Disabled

    = 1: Enabled

    d "Retry Count"

    = 0-10

    * When the "VOID print" is set to "Disabled", this parameter will not function. *1

    e "Host Notification"

    = 0: Disabled

    = 1: Enabled

    f "Specify the number of barcode"

    = 0: Command (the number of barcode command)

    = 1: Setting

    * The parameter functions only when the "mode" is set "Readable". *1

    g "the number of barcode"

    = 1-10: the number of barcode to read

    * When "Specify the number of barcode" is set to "Command", this parameter will not function. *1

Coding Example

  1. Mode: Disabled (all the subsequent parameters are omitted.)
    
    <A>
    <VB>0,,,,,,
    <Z>
     
  2. Mode: Readable, Start Position: 30, VOID print: Disabled, (Retry Count: omitted), Host Notification: Disabled, Specify the number of barcode: Command, (the number of barcode: omitted)
    
    <A>
    <VB>1,30,0,,0,0,
    <Z>
     
  3. Mode: Readable, Start Position: 30, VOID print: Enabled, Retry Count: 3, Host Notification: Disable, Specify the number of barcode: Setting, the number of barcode: 2
    
    <A>
    <VB>1,30,1,3,0,1,2
    <Z>
     
  4. Mode: Comparison, Start Position: 30, VOID print: Enabled, Retry Count: 3, Host Notification: Disabled, (Specify the number of barcode: omitted), (the number of barcode: omitted)
    
    <A>
    <VB>2,30,1,3,0,,
    <Z>
     

Supplemental explanation

  1. Each parameter can be omitted.

    1. When the non-functional parameter is specified, it will be set although it will not function.
  2. When RFID function is enabled, this command returns a command error.
  3. This command is not allowed to be used with other commands (it cannot be used in the printing item).