[ESC+WT] Calendar Setup

CL4NX CL6NX CL4NX-J CL6NX-J PW208/PW208m PW208NX/PW208mNX FX3-LX CT4-LX/HC4-LX PW4NX LR4NX-FA S84NX/S86NX CL4-SXR CL6-SXR

Hexadecimal code

ESC <1B>16
WT <57>16<54>16

Parameter

aabbccddee

Initial value

Nil

Valid range and term of command

When the power switch is OFF The set parameter is not maintained.
Valid range within items The set parameter is valid until the next valid setting.
Valid range between items The set parameter is valid until the next valid setting.

Function

Specifying the calendar.

Format

<WT>aabbccddee

  • Parameter

    a [Year] = Valid Range: 00 to 35

    b [Month] = Valid Range: 01 to 12

    c [Day] = Valid Range: 01 to 31

    d [Hour] = Valid Range: 00 to 23

    e [Minutes] = Valid Range: 00 to 59

Coding Example

2020.1.1 13:13


<A>
<WT>2001011313
<Z>
     

Supplementary Explanation

  1. This command requires optional calendar IC and it is non-usable without IC. (FX3-LX and S84NX/S86NX are already supported)
  2. Valid calendar setting value is from year: 2000, month: 1, day: 1, hour: 00, minutes: 00 to year: 2035, month: 12, day: 31, hour: 23, minutes: 59.
  3. There is a time lag before the printer system calendar is updated. If you use the <WT> command at the same time as printing, it may not be applied to printing.