[ESC+WT] Calendar Setup
CL4NX
CL6NX
CL4NX-J
CL6NX-J
PW208/PW208m
PW208NX/PW208mNX
FX3-LX
CT4-LX/HC4-LX
PW4NX
LR4NX-FA
S84NX/S86NX
CL4-SXR
CL6-SXR
Hexadecimal code
| ESC | <1B>16 |
|---|---|
| WT | <57>16<54>16 |
Parameter
aabbccddee
Initial value
Nil
Valid range and term of command
| When the power switch is OFF | The set parameter is not maintained. |
| Valid range within items | The set parameter is valid until the next valid setting. |
| Valid range between items | The set parameter is valid until the next valid setting. |
Function
Specifying the calendar.
Format
<WT>aabbccddee
-
Parameter
a [Year] = Valid Range: 00 to 35
b [Month] = Valid Range: 01 to 12
c [Day] = Valid Range: 01 to 31
d [Hour] = Valid Range: 00 to 23
e [Minutes] = Valid Range: 00 to 59
Coding Example
2020.1.1 13:13
<A>
<WT>2001011313
<Z>
Supplementary Explanation
- This command requires optional calendar IC and it is non-usable without IC. (FX3-LX and S84NX/S86NX are already supported)
- Valid calendar setting value is from year: 2000, month: 1, day: 1, hour: 00, minutes: 00 to year: 2035, month: 12, day: 31, hour: 23, minutes: 59.
- There is a time lag before the printer system calendar is updated. If you use the <WT> command at the same time as printing, it may not be applied to printing.