[ESC+&R] Form Overlay Call
CL4NX
CL6NX
CL4NX-J
CL6NX-J
PW208/PW208m
PW208NX/PW208mNX
FX3-LX
CT4-LX/HC4-LX
PW4NX
LR4NX-FA
S84NX/S86NX
CL4-SXR
CL6-SXR
Hexadecimal code
| ESC | <1B>16 |
|---|---|
| &R | <26>16<52>16 |
Parameter
,aa
Initial value
Nil
Valid range and term of command
| When the power switch is OFF | The set parameter is not maintained. |
| Valid range within items | The set parameter becomes invalid. |
| Valid range between items | The set parameter becomes invalid. |
Function
Invoking the contents in memory card with Registration of Form Overlay <&S>.
Format
<&R>,aa
-
Parameter
a [Registration Number] = Valid Range: 1 to 99
Coding Example
<A>
<CC>1
<&R>,1
<Z>
Supplementary Explanation
- Specify slot number of Card Slot for Use <CC> prior to this command when using.
- This command can be combined with different registration No. and printed.
- When registration No. is not specified, this command will be ignored.
- If specifying unregistered No., Read/Write error will occur.
- When registering without specifying window, Vertical Print Position <V> and Horizontal Print Position <H> will be ignored and V1 and H1 (Start position of drawing area) will be determined.
- When specifying and registering window, movement with <V> and <H> will be enabled.
Note that when exceeding print area, the portion outside of print area will not be printed.
- Please note that this command cannot be used without this command.
- The error occurs when specifying unused or specifying the slot which the printer is allocated.
Note
- Don't power off while accessing the memory. There is no guarantee of data in media if the power is turned off while accessing the memory.
Valid Command
Print position
<V>
<H>