[ESC+GI] Registration of Graphic

CL4NX CL6NX CL4NX-J CL6NX-J PW208/PW208m PW208NX/PW208mNX FX3-LX CT4-LX/HC4-LX PW4NX LR4NX-FA S84NX/S86NX CL4-SXR CL6-SXR

Hexadecimal code

ESC <1B>16
GI <47>16<49>16

Parameter

abbbcccdddn...n

Initial value

Nil

Valid range and term of command

When the power switch is OFF The set parameter is not maintained.
Valid range within items The set parameter becomes invalid.
Valid range between items The set parameter becomes invalid.

Function

Specifying the registration of graphic pattern data.

Format

<GI>abbbcccdddn...n

  • Parameter

    a [Selection of data transfer in HEX or BIN]

    = H: Hex data

    = B: Binary data

    Hex data (Divide 8 bits data into 4 bits and outputs it as hex code corresponding to ASCII)

    Binary data (Output 8 bits data as one character data all at once)


    b [Specification of crosswise graphic area per byte] = Refer to the table below (fixed at 3 digits)

    c [Specification of lengthwise graphic area per byte] = Refer to the table below (fixed at 3 digits)

    d [Registration number] (Identification number when invoking) = Valid range: 001 to 999 (fixed at 3 digits)

    n [Data] = Graphic data

Coding Example 1

[H: HEX data] is specified for [Data specification by HEX and BIN]

[□] is registered to the 999th of the slot 1 by the below.


<A>
<CC>1
<GI>H001001999<46463831383138313831383138314646>16
<Z>
 

Coding Example 2

[B: Binary data] is specified as Data specification by HEX and BIN]

[□] is registered to the 999th of the slot 1 by the below.


<A>
<CC>1
<GI>B001001999<FF818181818181FF>16
<Z>
                    

Supplementary Explanation

  1. Specify the card slot number used for Card Slot <CC> prior to this command.
  2. Specify registered data only.
  3. To change the registered content, clear it with Clear <*> to re-register.
  4. Graphic Call <GR> is for printing out the data registered with Registration of Graphic <GI>.
  5. When data is not registered properly, print error may occur.

    For details of data format, refer to [ESC+G] Graphic Print.

  6. The error occurs when specifying unused or specifying the slot which the printer is allocated.

Note

  1. Don't power off while accessing the memory. There is no guarantee of data in media if the power is turned off while accessing the memory.

Specified Range

Model Maximum byte in horizontal direction Maximum byte in vertical direction
CL4NX
CL4-SXR
203 dpi 104 400
305 dpi 156 600
609 dpi 312 999
CL6NX
CL6-SXR
203 dpi 152 (*1)
167 (*2)
400
305 dpi 248 (*1)
251 (*2)
600
PW208
PW208NX
PW208mNX
203 dpi 55 400
FX3-LX 305 dpi 120 600
CT4-LX
HC4-LX
203 dpi 104 400
305 dpi 156 600
PW4NX 203 dpi 104 400
LR4NX-FA 203 dpi 104 400
305 dpi 156 600
609 dpi 312 999
S84NX 203 dpi 104 400
305 dpi 156 600
609 dpi 312 999
S86NX 203 dpi 167 400
305 dpi 251 600

CL6NX/CL6NX-J/CL6-SXR

  1. Valid range in the case of setting "Standard" is "Valid range for print"
  2. Valid range in the case of setting "Left-justify" is "Valid range for print"