[ESC+GI] Registration of Graphic
Hexadecimal code
| ESC | <1B>16 |
|---|---|
| GI | <47>16<49>16 |
Parameter
abbbcccdddn...n
Initial value
Nil
Valid range and term of command
| When the power switch is OFF | The set parameter is not maintained. |
| Valid range within items | The set parameter becomes invalid. |
| Valid range between items | The set parameter becomes invalid. |
Function
Specifying the registration of graphic pattern data.
Format
<GI>abbbcccdddn...n
-
Parameter
a [Selection of data transfer in HEX or BIN]
= H: Hex data
= B: Binary data
Hex data (Divide 8 bits data into 4 bits and outputs it as hex code corresponding to ASCII)
Binary data (Output 8 bits data as one character data all at once)
b [Specification of crosswise graphic area per byte] = Refer to the table below (fixed at 3 digits)
c [Specification of lengthwise graphic area per byte] = Refer to the table below (fixed at 3 digits)
d [Registration number] (Identification number when invoking) = Valid range: 001 to 999 (fixed at 3 digits)
n [Data] = Graphic data
Coding Example 1
[H: HEX data] is specified for [Data specification by HEX and BIN]
[□] is registered to the 999th of the slot 1 by the below.
<A>
<CC>1
<GI>H001001999<46463831383138313831383138314646>16
<Z>
Coding Example 2
[B: Binary data] is specified as Data specification by HEX and BIN]
[□] is registered to the 999th of the slot 1 by the below.
<A>
<CC>1
<GI>B001001999<FF818181818181FF>16
<Z>
Supplementary Explanation
- Specify the card slot number used for Card Slot <CC> prior to this command.
- Specify registered data only.
- To change the registered content, clear it with Clear <*> to re-register.
- Graphic Call <GR> is for printing out the data registered with Registration of Graphic <GI>.
- When data is not registered properly, print error may occur.
For details of data format, refer to [ESC+G] Graphic Print.
- The error occurs when specifying unused or specifying the slot which the printer is allocated.
Note
- Don't power off while accessing the memory. There is no guarantee of data in media if the power is turned off while accessing the memory.
Specified Range
| Model | Maximum byte in horizontal direction | Maximum byte in vertical direction | |
|---|---|---|---|
| CL4NX CL4-SXR |
203 dpi | 104 | 400 |
| 305 dpi | 156 | 600 | |
| 609 dpi | 312 | 999 | |
| CL6NX CL6-SXR |
203 dpi | 152 (*1) 167 (*2) |
400 |
| 305 dpi | 248 (*1) 251 (*2) |
600 | |
| PW208 PW208NX PW208mNX |
203 dpi | 55 | 400 |
| FX3-LX | 305 dpi | 120 | 600 |
| CT4-LX HC4-LX |
203 dpi | 104 | 400 |
| 305 dpi | 156 | 600 | |
| PW4NX | 203 dpi | 104 | 400 |
| LR4NX-FA | 203 dpi | 104 | 400 |
| 305 dpi | 156 | 600 | |
| 609 dpi | 312 | 999 | |
| S84NX | 203 dpi | 104 | 400 |
| 305 dpi | 156 | 600 | |
| 609 dpi | 312 | 999 | |
| S86NX | 203 dpi | 167 | 400 |
| 305 dpi | 251 | 600 | |
CL6NX/CL6NX-J/CL6-SXR
- Valid range in the case of setting "Standard" is "Valid range for print"