[ESC+/D] Print of Field

CL4NX CL6NX CL4NX-J CL6NX-J PW208/PW208m PW208NX/PW208mNX FX3-LX CT4-LX/HC4-LX PW4NX LR4NX-FA S84NX/S86NX CL4-SXR CL6-SXR

Hexadecimal code

ESC <1B>16
/D <2F>16<44>16

Parameter

,aa,n...n

Initial value

Nil

Valid range and term of command

When the power switch is OFF The set parameter is not maintained.
Valid range within items The set parameter is valid until the next valid setting.
Valid range between items The set parameter is valid until the next valid setting.

Function

Invoking the items registered with Registration of Field and specifying data.

Format

</D>,aa,n...n

  • Parameter

    a [Field number] = Valid Range: 1 to 99

    n [Data] = Data to be changed

Coding Example


<A>
<CC>1
<YR>,1
</D>,1,DEF
</D>,2,78901
</D>,3,49000238
<Q>2
<Z>
 

Supplementary Explanation

  1. Digit number of print is valid within the range specified with Registration of Field </N>.
  2. When digit number of this command is larger than the one specified with Registration of Field </N>, only the defined digit No. will be available for printing.
  3. Use this command and Format Call <YR> as a pair.
  4. The error occurs when specifying unused or specifying the slot which the printer is allocated.

Note

  1. Don't power off while accessing the memory. There is no guarantee of data in media if the power is turned off while accessing the memory.