[ESC+/D] Print of Field
CL4NX
CL6NX
CL4NX-J
CL6NX-J
PW208/PW208m
PW208NX/PW208mNX
FX3-LX
CT4-LX/HC4-LX
PW4NX
LR4NX-FA
S84NX/S86NX
CL4-SXR
CL6-SXR
Hexadecimal code
| ESC | <1B>16 |
|---|---|
| /D | <2F>16<44>16 |
Parameter
,aa,n...n
Initial value
Nil
Valid range and term of command
| When the power switch is OFF | The set parameter is not maintained. |
| Valid range within items | The set parameter is valid until the next valid setting. |
| Valid range between items | The set parameter is valid until the next valid setting. |
Function
Invoking the items registered with Registration of Field and specifying data.
Format
</D>,aa,n...n
-
Parameter
a [Field number] = Valid Range: 1 to 99
n [Data] = Data to be changed
Coding Example
<A>
<CC>1
<YR>,1
</D>,1,DEF
</D>,2,78901
</D>,3,49000238
<Q>2
<Z>
Supplementary Explanation
- Digit number of print is valid within the range specified with Registration of Field </N>.
- When digit number of this command is larger than the one specified with Registration of Field </N>, only the defined digit No. will be available for printing.
- Use this command and Format Call <YR> as a pair.
- The error occurs when specifying unused or specifying the slot which the printer is allocated.
Note
- Don't power off while accessing the memory. There is no guarantee of data in media if the power is turned off while accessing the memory.