[ESC+/N] Registration of Field
Hexadecimal code
| ESC | <1B>16 |
|---|---|
| /N | <2F>16<4E>16 |
Parameter
,aa,bb
Initial value
Nil
Valid range and term of command
| When the power switch is OFF | The set parameter is not maintained. |
| Valid range within item | The set parameter is valid until the next valid setting. |
| Valid range between items | The set parameter is valid until the next valid setting. |
Function
Registering items within the field of Registration of Format <YS>.
Format
</N>,aa,bb
-
Parameter
a [Field number] = Valid Range: 1 to 99
b [Digit number of print] = Valid Range: 1 to 99
Coding Example
<A>
<CC>1
<YS>,1
</N>,1,3
<%>0<V>100<H>200<P>2<L>0101<XM>ABC
</N>,2,5
<%>0<V>200<H>200<P>2<L>0101<OA>12345
</N>,3,8
<%>0<V>300<H>40<B>40208049123456
<Z>
Supplementary Explanation
- Specify the value of [Field number] in ascending order.
- Specify Vertical Print Position <V> and Horizontal Print Position <H> for each field. If not, default value will be set.
- Specification of digit number when printing external character.
External code H, one external character has 4 digits; thus, three external characters make 12 digits for printing.
External code B, one external character has 2 digits; thus, three external characters make 6 digits for printing.
- Use this command and Registration of Format <YS> as a pair.
- Due to the memory capacity limit, it may not save up to 99 registries.
- The error occurs when specifying unused or specifying the slot which the printer is allocated.
Note
- Don't power off while accessing the memory. There is no guarantee of data in media if the power is turned off while accessing the memory.
Designable Commands for the Change of Print
Font
<XU>
<XS>
<XM>
<XB>
<XL>
<OA>
<OB>
<RD>
<$=>
<K1>
<K2>
<K3>
<K4>
<K5>
<K8>
<K9>
<KA>
<KB>
<KD>
<k1>
<k2>
<k3>
<k4>
<k5>
<k8>
<k9>
<kA>
<kB>
<kD>
<X20>
<X21>
<X22>
<X23>
<X24>
<PP>
<X1>
<X2>
<X3>
<X80>
<X81>
<X82>
<X83>
<X84>
<X85>
<X86>
<X87>
<X88>
<XK>
<PP1>
<PP2>
<PP3>
<RG>
<RH>
<Xa1>-<Xa6>
<Xb1>-<Xb8>
<Xc1>-<Xc9>
<Xd1>-<Xd9>
<Xe1>-<Xe9>
<Xf1>-<Xf5>
<Xm1>-<Xm4>
Modification
<P>
<L>
<PS>
<PR>
<%>
Barcode
<B>
<BC>
<BG>
<BI>
<D>
<BD>
<BW>
<BL>
- Character code: UNICODE (UTF-16 BE) is not supported.