[ESC+IP0] RFID Write (UHF) [SX]

CL4-SXR CL6-SXR

HEX code

ESC <1B>16
IP0 <49>16<50>16<30>16

Parameter

See under "Parameters".

Default Value

Nil

Valid range and term of command

When turning off the power switch The set command is not maintained.
Valid range within item The set parameter becomes invalid.
Valid range between items The set parameter becomes invalid.

Function

This command writes the EPC code and other data to the EPC corresponding RFID tag. The standard format (three-character parameter identifier) is used when using the memory area extended for each IC chip manufacturer.

Available in RFID module (UHF band) installed printers.

Format(Standard format)

<IP0>e:h(,pcw:xxx) (,epc:xxxx...xxxx)|(,epa:dddd,aaaaa...aaaa) (,usr:xxxx...xxxx)|(,usa:dddd,aaaaa...aaaa) (,lck:bbbbb) ;

Note: Typical parameters are shown in the format examples above. Refer to the next item for details on the parameters.

  • Parameter

EPC encode type parameter
e: EPC encode Type

Specify the parameter right after <IP0>.

The parameter cannot be omitted.

h [Standard format]

Use the three-character parameter identifier after the declaration.

In addition to the standard Gen2 tag, it is possible to write to the memory area extended for each IC chip manufacturer.

Standard format parameters

This is the extended format for the tag from IC chip manufacturer having over 96 bits EPC area.

<IP0>e: Write these parameters after specifying h.

<IP0>e: The order of the parameters after specifying h doesn't matter.

Three-character parameter identifier
Gen 2 basic operation parameters (can be omitted)
pcw: PC rewrite The PC area contains length information for controlling the number of digits of data to be recorded to the EPC. You can change the number of digits of the EPC data by specifying multiples of four from 0 to 124 in decimal code to this parameter.

Specifying this parameter is not necessary in most cases because the length information is written to the PC automatically by judging from the data length specified by epc:, if this parameter is not specified. (Maximum value of the length information of PC is 124 digits.)

afi: AFI write data Specify the number from 000 to 1FF in HEX code. Synthesize data together with current PC length information and write.
epc: EPC write data Specify 4 to 124 digit number in HEX code corresponding to the traditionally written data in the EPC area. Digits can be varied in multiples of four. When the character string is longer than the digits specified by pcw:, a parameter error occurs, and when the character string is shorter, the blanks are filled with zeros.

You may also use the space, tab, line feed in data separator, but these codes will be skipped.

Specifying digits other than digits of multiples of 4 will cause a parameter error. Specifying digits exceeding the maximum number of digits will cause RFID write error.

epa: EPC memory

ASCII write

Specify numbers to write to EPC area in ASCII. Data that includes Control code (00H-1FH) can be written as well.

Note that size information of the data area separated with comma is required in front of the data.

Example:

If the data size is 62, specify epa:62,abcde...

The digits should be a multiple of 2.

The numbers should be specified within 2-62 digits, but the maximum number of digits depends on the tag in use.

Specifying odd number digits will cause a parameter error. Specifying digits exceeding the maximum number of digits will cause RFID write error.

usr: USER memory write Specify numbers to write to USER area in hexadecimals. It must be specified in digits that are multiples of 4.

The numbers should be within 4-512 digits, but the maximum number of digits depends on the tag in use. You may also use the space, tab, line feed in data separator, but these codes will be skipped.

Specifying digits other than digits of multiples of 4 will cause a parameter error. Specifying digits exceeding the maximum number of digits will cause RFID write error.

usa: USER memory

ASCII write

Specify numbers to write to USER area in ASCII. Data that includes Control code (00H-1FH) can be written as well.

Note that size information of the data area separated with comma is required in front of the data.

Example:
If the data size is 64, specify usa:64,abcde...

The digits should be a multiple of 2.

The numbers should be specified within 2-256 digits, but the maximum number of digits depends on the tag in use.

Specifying odd number digits will cause a parameter error. Specifying digits exceeding the maximum number of digits will cause RFID write error.


Parameters related to specifying USER Memory Block to start writing (omissible)
wsb: Specify block to start writing Specifies the block to start writing the USER memory data. The 0th block is specified if omitted.

Block is a unit to write to user memory. Take the values in the following table.

A maximum up to a 3-digit decimal can be specified, but a parameter error occurs if it exceeds the maximum amount for the specified memory (128 and above). See the following table.

Memory area Capacity of 1 block Total number of blocks Total capacity
USER Memory 2bytes 128blocks 256bytes

Only USER memory is available.


Operation parameters in standard format (can be omitted)
lck: Lock Specify the area to be locked by five bits in binary code such as lck:10101.

The order is from the first digit to USER,TID,ACCESS,KILL,EPC. If the access password is specified, it results in a password lock, and if the access password is not specified, it results in a permanent lock.

Bit Section to be locked
bit0 (LSB) EPCdata
bit1 KillCode
bit2 AccessCode
bit3 TIDdata
bit4 (MSB) UserMemory

Note: Impinj Monza R6 is a IC chip for which EPC permanent lock is only an available feature. Using 11111 for 5-bit block (ex. "lck:11111") can use the lock feature.

* Cannot be specified at the same time as "lc2 (lock specification)".

lc2: Lock Specify the area to be locked by 10-digit character (ex. lc2:1011XX0001). The order is from the upper two digits to USER, TID, ACCESS, KILL, and EPC. Detailed lock can be applied by specifying the following bits for each area.
Bit specification Lock item
00 Unlock
01 Permanent Unlock
10 Password Lock/Password Read Lock
11 Permanent Lock
XX Mask

Note: Impinj Monza R6 is a IC chip for which EPC permanent lock is only an available feature. However using 11111 for 5-bit block (ex. "lc2:1111111111") can use a lock feature.

* Cannot be specified at the same time as "lck (lock specification)".

apw: Access password To perform locking or read protecting with a password, specify an eight-character HEX code.

* Cannot be specified together with Unlocking password (psw:) at the same time.

* When specify this parameter, please specify with writing parameter like an epc:.

* Please specify a password other than "00000000".

psw: Unlocking password To access an area on which a password lock or password read lock is applied, specify the same number sequence as that used when locking.

Specify unlocking area with lck: or lc2:.

kpw: Kill code Specify the kill code with eight-character HEX code. You cannot execute the kill by writing the code only.

NXP G2XL dedicated secure parameters (can be omitted)

(Cannot be used in a Gen2 chip other than NXP G2XL.)

rlk: G2X, Read protection Specify 0 or 1 to indicate whether read protection is to be set or canceled. 1 for set and 0 for reset. When read protection is set, the reading of all areas becomes restricted.

You must concurrently use an access password other than "00000000", and for reset, specify the same number sequence as the access password used during setting, in the cancellation password. (dedicated for NXP G2XL)

eas: G2X, EAS bit data Specify 0 or 1 as the value of the EAS bit. 1 for set and 0 for reset.

You must concurrently use an access password other than "00000000", and for reset, specify the same number sequence as the access password used during setting, in the cancellation password. (dedicated for NXP G2XL)


NXP G2iM/G2iL dedicated secure parameters (can be omitted)

(Cannot be used in a Gen2 chip other than NXP G2iM/G2iL.)

rlk: G2I, Read protection Specify 0 or 1 to indicate whether read protection is to be set or canceled. 1 for set and 0 for reset. When read protection is set, the reading of all areas becomes restricted.

You must concurrently use an access password other than "00000000", and for reset, specify the same number sequence as the access password used during setting, in the cancellation password. (dedicated for NXP G2im/G2iL)

eas: G2I, EAS bit data Specify 0 or 1 as the value of the EAS bit. 1 for set and 0 for reset.

You must concurrently use an access password other than "00000000", and for reset, specify the same number sequence as the access password used during setting, in the cancellation password. (dedicated for NXP G2im/G2iL)


Feed control parameters (can be omitted)
fsw: Feed without printing Usually, for RFID write item without print data, only writing of RFID data is performed, and the label is not fed.
Parameter Performance
0 Label-feed will stop (if the data does not include print items); the same operation with when fsw: is not specified.
1 Label-feed will start (if the data does not include print items).
2 Write only can be executed without label-feed/print. Due to this, label-write test can be executed without using a label.

If don't feed, short buzzer will sound 2 times when write is successful. Short buzzer will the sound 6 times when it fails to write.


SSCC96/SGTIN96 standard code conversion parameters
enc: Declaration of code standard conversion Declare when executing conversion according to the code standard. SSCC96 and SGTIN96 can be specified. The converted data is written in the EPC area. Therefore, you can no longer use the epc: parameter identifier
Parameter Conversion
a SSCC96
c SGTIN96
d GRAI96
e GIAI96
flt: Filter value Specify the filter value with the number from 0 to 7. Refer to the filter value standard table described later. If omitted, 0 is specified.
com: Company prefix

Specified

Specify the company prefix with 6 to 12-digit decimal number.
srl: Serial reference In the case of SSCC96, specify the serial reference with 5 to 11-digit decimal number together with the number sequence specified in com:, so that the value is 17 digits or less. Even if the value does not reach 17 digits, leave it as is since the upper digits are filled with a zero inside the printer.
In the case of SGTIN96, specify the serial number as a decimal number of 12 digits or less. Please specify a number of 274877906943 or less.

Even if the value does not reach 12 digits, leave it as is since the upper digits are filled with a zero inside the printer.

In the case of GRAI96, specify the serial number as a decimal number of 12 digits or less. Specify a number of 274877906943 or less.

Even if the value does not reach 12 digits, leave it as is since the upper digits are filled with a zero inside the printer.

itm: Item reference (Only for SGTIN96) Specify the item reference with 1 to 7-digit decimal number together with the number sequence specified in com:, so that the value is 13 digits or less.

Even if the value does not reach 13 digits, leave it as is since the upper digits are filled with a zero inside the printer.

ast: Asset Type In the case of GRAI96, specify the asset type using a 1- to 6-digit decimal number, making the total length 12 digits or less, together with the numeric string specified in com:.

Even if the value does not reach 12 digits, leave it as is since the upper digits are filled with a zero inside the printer.

If the number of digits specified in com: is 12, this specification will be invalid.
Individual Asset Reference Number In the case of GIAI96, specify the individual asset reference number as a 13- to 19-digit decimal number that, when combined with the string specified in com:, results in a total of 25 digits or less.

Even if the value does not reach 25 digits, leave it as is since the upper digits are filled with a zero inside the printer.

An error will occur if 'com:' is less than 6 digits. However, if 'com:' is 6 digits or more and 'ast:' has at least 1 digit specified, zero-padding will be applied to make the total length 25 digits.


IC chip specification parameters (can be omitted)

ict: EM4425 Chip Write Declaration Parameter
Specifies the type of IC chip to write data to.

When omitted, the IC chip type is "00" (= invalid).

If you wish to use the unique functions of the IC chip listed below, you must specify it.

Also, please make sure to write the parameter "ict:" before the parameters explained below. If you write it after them, a command error will occur.

  • For EM4425 chips: scr:, ncf:, ndt:, ncl:, tlw:, ahc:, ckb:
  • For M700 chips: srm:, ukm:
  • For Monza R6-P chips: mps:
IC chip type Product Note
00 Conventional IC chip other than the following Same as when this parameter is omitted
01 EM4425 Dual Frequency Tag
03 Impinj M730, M770, M780
04 Impinj MonzaR6-P
scr: System Configuration Block1 register specifying parameter
(* Not available for EM4425-v10)
Specify a parameter to write to System Configuration register (UHF User Memory 120h - 122h) by 12 digit hex number.

Other numbers than 12 digit hex number will be considered a parameter error.

e.g. scr:210447F08000

ncf: OTP NDEF Configuration register specifying parameter
(* Not available for EM4425-v10)
Specify a parameter to write to OTP NDEF Configuration register (UHF Reserved Word 1Ch - 1Fh) by 16 digit hex number.

Other numbers than 16 digit hex number will be considered a parameter error.

e.g. ncf:F939004B1E520000

ndt: NDEF memory block data selection
Specify the data to write to NDEF memory block (UHF User Memory A0h -).

Specify binary type data followed by the max 3 digit decimal number length and a comma.

Within the valid range of 256 bytes. However, use less than or equal to the capacity of the NDEF memory block setting described in "scr:" (System Configuration Block 1 register).

e.g. ndt:nnn,bb...bb (set the NDEF data to bb...bb)


EM microelectronic EM4425 write-related parameters
ncl: OTP NDEF Configuration Lock Word register specifying parameter

(* Not available for EM4425-v10)

Specify the setting value to be written to the OTP NDEF Configuration Lock Word register (UHF User Memory 12Dh) as a 4-digit hexadecimal number; otherwise, a parameter error will result. Normally, "8000" is specified, but any value between 0000 and FFFFF will produce the same result.

When writing, the OTP NDEF Configuration register (UHF Reserved Word 1Ch to 1Fh) becomes read-only.

If this parameter is not specified, the OTP NDEF Configuration register is not read-only locked.

Example: ncl:8000

tlw: Tamper Lock Word register specifying parameter
(* Not available for EM4425-v10)
Specify a parameter to write to Tamper Lock Word register (UHF User Memory 12Ch) by 4 digit hex number.

After Tamper is locked, the written Tamper Alarm of non-volatile memory will be valid.

Other numbers than 4 digit hex number will be considered a parameter error. "8000" shall be specified at normal situation.

Once write a value of "8000" or more to enable the Tamper Alarm, this register cannot be changed and specifying tlw: again will result in an error.

If this parameter is not specified or a number less than "8000" is specified, the written Tamper Alarm non-volatile memory will not be valid.

Tamper Detection setting shall be performed at System Configuration Block 1.

e.g. tlw:8000

ahc: Active HF Crypto Mode Word register specifying parameter
(* Not available for EM4425-v10)
Specify a parameter to write to Active HF Crypto Mode Word register (UHF User Memory 126h) by 4 digit hex number. Other numbers than 4 digit hex number will be considered a parameter error. "8000" shall be specified at normal situation. But specifying any number from 0000 to FFFF will have the same result.

Once HF encryption mode is enabled, this register cannot be changed and specifying ahc: again will result in an error.

If this parameter is not specified, the setting will not move to HF Crypto Mode and the tag will not respond to NFC in the HF side.

e.g. ahc:8000

ckb: Crypto Key Block 3/4 register specifying parameter
(* Not available for EM4425-v10)
Specify a parameter to write to Crypto Key Block 3/4 register (UHF Reserved Word 0Ch - 13h) by 32 digit hex number. Other numbers than 32 digit hex number will be considered a parameter error.

e.g. ckb:FEDCBA9876543210FEDCBA9876543210

srm: Short range setting parameters
(* Only for M730, M770, M780)

This sets the short range mode.
Enabling this setting reduces the read distance to approximately 1/10 of the normal read distance.
0: Disables short range mode (same as when omitted)
1: Enables short range mode (sets the SR bit in Reserved area 4h to ON (1)).
To enable short range mode, you must specify an access password other than 0. When enabling this setting, also specify "apw:".
To disable short range mode, you must specify the access password that was specified when it was enabled. Also specify the password with "psw:".

Note:
Enabling this setting shortens the read distance, which may prevent the printer from reading again. For this reason, write verification is not performed immediately after enabling short range mode.

例)ckb:FEDCBA9876543210FEDCBA9876543210

ukm: Unkillable configuration parameters
(* Only for M770, M780)

Specifies the unkillable mode setting.
When enabled, the tag will be permanently unerasable.
0: Disable unkillable mode (same as omitting this setting)
1: Enable unkillable mode (sets the UK bit in Reserved area 4h to ON (1)).
Once unkillable mode is enabled (1), it cannot be disabled (0) again. In this case, this parameter will be ignored.

mps: Memory Map Selection Configuration Parameter
(* Only for MonzaR6-P)

This sets the Memory Map Selection.
This setting configures the IC chip's memory configuration as follows:
0: EPC 128 bits / USER 32 bits (same as when omitted)
1: EPC 96 bits / USER 64 bits
Once Memory Map Selection is set, it cannot be changed again. In that case, this parameter will be ignored.

* In EM4425-v10, writing the "scr:", "ncf:", "ncl:", "tlw:", "ahc:", and "ckb:" parameters will cause a write error because the corresponding register is write-protected in advance. Please be careful not to write these parameters.

Coding examples of the standard format (three-character parameter identifier)

Coding example 1

When data is written in an arbitrary length in the EPC region in the IC chip manufacturer extension specifications tag


<A>
<V>50<H>50<XM>SECURE RFID EPC DATA WRITE
<IP0>e:h,epc:01234567890123456789012345678901; (in digits that are multiples of 4)
<Q>1
<Z>
                    
Coding example 2

When EPC and user memory are written in a batch in the IC chip manufacturer extension specifications tag, and permanent lock operation on EPC and user memory.


<A>
<V>50<H>50<XM>SECURE RFID EPC & USER DATA WRITE
<IP0>e:h,epc:01234567890123456789012345678901,usr:012345678.........5676789012345678901,lck:10001;
<Q>1
<Z>
                
Coding example 3

When data is written in EPC by specifying the SSCC96 standard code conversion in the Gen2 tag, and permanent locking is performed the EPC.


<A>
<V>50<H>50<XM>SECURE RFID SSCC96 DATA WRITE
<IP0>e:h,enc:a,flt:0,com:12345678,srl:012345678,lck:00001;
<Q>1
<Z>
                 
Coding example 4

When data is written in EPC by specifying the SGTIN96 standard code conversion in the Gen2 tag


<A>
<V>50<H>50<XM>SECURE RFID SGTIN96 DATA WRITE
<IP0>e:h,enc:c,flt:0,com:123456,itm:0123456,srl:012345678901;
<Q>1
<Z>
               
Coding example 5

Writes data to EPC of tag after the printer convert it to the SGTIN96 standard code. And writes standard data to USER of tag.


<A>
<V>50<H>50<XM>SECURE RFID SGTIN96 DATA WRITE
<IP0>e:h,enc:c,flt:0,com:123456,itm:0123456,srl:012345678901,usr:01234567;
<Q>1
<Z>
            
Coding example 6

Writes data to EPC of new tag and performing password locks operation ACCESS and EPC


<A>
<IP0>e:h,epc:77914949,apw:456E9897,lck:00101;
<Q>1
<Z>
                    
Coding example 7

When data to EPC by unlocking ACCESS and EPC for the tag that locked ACCESS and EPC in coating example 6 (Password is the set password when locking.)

* Cannot specify Access password (apw:) at this time.


<A>
<IP0>e:h,psw:456E9897,epc:77914948,lck:00101;
<Q>1
<Z>
                    
Coding example 8

When writing data in the EPC area of the IC chip "Impinj Monza R6" tag (unlocked tag) and permanently locking the EPC (* Impinj Monza R6 is an IC chip in which permanent lock of the EPC only can be executed).


<A>
<IP0>e:h,epc:77914949,lck:11111;
<Q>1
<Z>
                    
Coding example 9

When writing EPC and USER to a new tag (unlocked tag) and performing a permanent lock operation on the EPC area


<A>
<IP0>e:h,epc:012345678901,usr:E0123456,lc2:XXXXXXXX11; 
<Q>1
<Z>
                    
Coding example 10

When only wiritng data in the EPC area of the tag(EPC write test/non-print feed)


<A>
<IP0>e:h,epc:77914949,fsw:2;
<Q>1
<Z>
                    
Coding example 11

When writing data in the EPC area of the tag and writing 12 byte data of "111122223333" from block 5 in the USER area.


<A>
<IP0>e:h,epc:77914949, usr: 111122223333,wsb:5;
<Q>1
<Z>
                    
Coding example 12

Set the system configuration to determine the memory allocation between the EPC and NDEF data areas of EM microelectronic EM4425-v12 tags, write the 24-digit EPC to the EPC area and the 25-character URI information to the NDEF area, activate the HF crypto mode, and lock each register. In the case of issuing a tag for a smart poster by locking each registers.


<A>
<IP0>e:h,epc:012345678901234567890123,ict:01,scr:210447F08000,ncf:F800000000000000,ndt:025,(E1) (40) (13
) (01) (03) (12) (D1) (01) (0E) (55) (04) nfc.tapee.net(FE) ,ncl:8000,ahc:8000,fsw:1;
<Q>1
<Z>
                    

* " (E1) " represents the binary code E1h

Coding example 13

When issuing a tag for smart posters by writing a 24-digit EPC in the EPC area and 25-character URI information in the NDEF area of an EM4425-v10 tag manufactured by EM microelectronic.


<A>
<IP0>e:h,epc:012345678901234567890123,ict:01,ndt:025,(E1) (40) (17) (01) (03) (12) (D1) (01) (0E) (55) (04) nfc.t
apee.net(FE) ,fsw:1;
<Q>1
<Z>
                 
Coding example 14

When specifying GRAI96 standard code conversion for Gen2 tags and writing data to EPC


<A>
<IP0>e:h,enc:d,flt:0,com:4912345,ast:12345,srl:000001002348;
ee.net(FE),fsw:1;
<Q>1
<Z>
                 
Coding example 15

When specifying GIAI96 standard code conversion for Gen2 tags and writing data to EPC


<A>
<IP0>e:h,enc:e,flt:0,com:4912345,ast:000000001234567890;
ee.net(FE),fsw:1;
<Q>1
<Z>
                 
Coding example 16

Writes data to the EPC area of Impinj M730, M770, and M780 tags and enables short range mode.


<A>
<IP0>e:h,epc:012345678901234567890123,ict:3,apw:12345678,srm:1;
ee.net(FE),fsw:1;
<Q>1
<Z>
                 
Coding example 17

Write data to the EPC area of Impinj M770 and M780 tags and enable unkillable mode.


<A>
<IP0>e:h,epc:012345678901234567890123,ict:3,ukm:1;
ee.net(FE),fsw:1;
<Q>1
<Z>
                 
Coding example 18

The USER area of the Impinj MonzaR6-P tag is expanded to 64 bits, and 64-bit data is written.


<A>
<IP0>e:h,usr:3132333435363738,ict:4,mps:1;
ee.net(FE),fsw:1;
<Q>1
<Z>
                 

* " (E1) " represents the binary code E1h

Coding examples of one-character parameter identifiers

(SSCC96 code conversion / SGTIN96 code conversion / free mapping)

Coding example 1

Country code 49 /Company code 12345 / Serial no. 0000000 789

When SSCC 96 data is written to a Gen2 corresponding tag


<A>
<V>50<H>50<XM>49123450000000789
<IP0>e:a,c:7,s:10,f:1,d:49123450000000789;
<Q>1
<Z>
                    
Coding example 2

Country code 49 /Company code 12345 / Item 067890 / Serial no. 000000000789

When SGTIN96 data is written to a Gen2 corresponding tag


<A>
<V>50<H>50<XM>4912345067890000000000789
<IP0>e:c,c:7,t:6,f:1,d:4912345067890,n:000000000789;
<Q>1
<Z>
                    
Coding example 3

When free mapping data is written in the EPC area of a Gen2 corresponding tag


<A>
<V>50<H>50<BD>101080*301803CB4F48B38000000001*
<IP0>e:z,d:301803CB4F48B38000000001;
<Q>1
<Z>
                    
Coding example 4

When data is written in free mapping in the EPC area of a Gen2 corresponding tag, data is written in the user area, and at the same time, a permanent lock is applied to both the EPC and USER areas


<A>
<V>50<H>50<BD>101080*0123456789ABCDEF01234567*
<IP0>e:z,d:0123456789ABCDEF01234567,u:0123456789ABCDEF0123456789ABCDEF0123456789ABCDEF,m:10001;
<Q>1
<Z>
                    
Coding example 5

When data is written in free mapping in the EPC area of a Gen2 corresponding tag, and a password lock (Password: 12345678) is applied to the EPC area


<A>
<V>50<H>50<BD>101080*0123456789ABCDEF01234567*
<IP0>e:z,d:0123456789ABCDEF01234567,a:12345678,m:00101;
<Q>1
<Z>
                    

Supplemental explanation

  1. This command can be used only once between the data transmit start <A> to the data transmit end <Z>.
  2. When print data is to be included beside EPC code write, multiple labels can be specified. If there is no print data as in Example 2, media is not fed. If a blank media is to be fed after EPC code write, specify feeding without print as in Example 3.


    [Example 1] If print data is included, the QTY can be specified.

    
    <A>
    <V>50<H>50<XM>0123456789ABCDEF01234567
    <IP0>e:z,d:0123456789ABCDEF01234567;
    <Q>1
    <Z>
     

    [Example 2] If you specify EPC code write without print data, the media is not fed, and QTY cannot be specified.

    
    <A>
    <IP0>e:z,d:0123456789ABCDEF01234567;
    <Z>
     

    [Example 3] If there is no print data, but you have specified feeding without print in EPC code write, the media is fed, and QTY can be specified.

    
    <A><IP0>e:z,d:0123456789ABCDEF01234567,g:1; <Q>2<Z>
     

    or

    
    <A><IP0>e:h,epc:0123456789ABCDEF01234567,fsw:1;<Q>2<Z> (for the standard format)
     

    Example 1 Example 2 Example 3
    When EPC code write is successful Print, feed Don't feed
    Two short beeps
    Feed a blank label
    When EPC code write has failed Print tag error
    Retry operation
    Six short beeps Print tag error
    Retry operation
  3. * If you have set TAG OFFSET to other tan the default value, or if you have specified temporary tag offset, feeding is performed in Example 2 as well.

  4. Buzzer will sound in the following manner.

    EPC code write success/fail will be notified with the following buzzers only when EPC code write is specified without print data:

    EPC code write is successful: Two short buzzer sounds

    EPC code write fails: Six short buzzer sounds

    Buzzer sound for after EPC code write can be changed according to settings under System -> Sound -> Error Sound.

  5. If 0 is specified in the fsw: parameter for the item without printing data: when sending this command, send it when the printer stops printing and the printing items are not available in the printer.
  6. Unused parameters can be omitted.
  7. For details on the filter value to be used with SSCC96/SGTIN96, refer to the table below according to the purpose of use.

    Filter value standard table

    Filter value SSCC96 SGTIN96
    0 All Others All Others
    1 Reserved Point of Sale (POS) Trade Item
    2 Full Case for Transport Full Case for Transport
    3 Reserved Reserved
    4 Reserved Inner Pack Trade Item Grouping for Handling
    5 Reserved Reserved
    6 Unit Load Unit Load
    7 Reserved Unit inside Trade Item or component inside a product not intended for individual sale
  8. SSCC96 code conversion

    This function is used to generate a code according to the SSCC96 standard when a company prefix, serial reference, and filter value are applied.

    For the time being, the usage method is explained by using an example in which the following numbers have been applied. All numbers are in decimals.

    Company prefix: 4011661

    Serial reference: 3000000001

    Filter value: 0 (Select the filter value from the filter value standard table described earlier according to the purpose of use. In this example, the filter value is 0 from "All Others")

    According to the standard, the company prefix and serial reference are combined together to result in 17 digits. Of these 17 digits, the proportion of the company prefix and the serial reference can be selected from the seven combinations described in the table below.

    Partition value Number of digit of the company prefix Number of digits of the serial reference
    0 12 5
    1 11 6
    2 10 7
    3 9 8
    4 8 9
    5 7 10
    6 6 11

    In the case shown in this example, the following combination is assumed:

    Number of digits of the company prefix: 7

    Number of digits of serial reference: 10

    The partition value is 5, but since this value is generated within the PC, it need not be specified.


    Under this condition, if the format of EPC code write <IPO> is applied, it results in the following:


    When the standard format is used

    
    <IP0>e:h,enc:a,com:4011661,srl: 3000000001,flt:0;
     

    Description of each parameter

    Code Explanation
    e:h,
    Specifies the standard format
    enc:a
    Specifies SSCC96 code conversion
    com:4011661,
    The company prefix is 4011661
    srl:3000000001,
    The serial reference is 3000000001 17 digits when combined with com:
    flt:0
    The filter value is All Others
    ;
    End terminal

    When these commands are executed, the above parameters are converted to SSCC96 code 3114F4DA34B2D05E01000000 and 24 characters (18 characters in actuality), and are written in a tag.

  9. SGTIN96 code conversion

    This function is used to generate a code according to the SGTIN96 standard when a company prefix, item reference, filter value, and serial number are applied. For the time being, the usage method is explained by using an example in which the following numbers have been applied. All numbers below are in decimals.

    Company prefix: 003885

    Item reference: 4006606

    Filter value: 0 (Select the filter value from the filter value standard table described earlier according to the purpose of use. In this example, the filter value is 0 from "All Others")

    Serial number: 000000000001 (fixed as 12 digits)

    According to the standard, the company prefix and item reference are combined together to result in 13 digits. Of these 13 digits, the proportion of the company prefix and the item reference can be selected from the seven combinations described in the table below.

    Partition value Number of digit of the company prefix Number of digit of the item reference
    0 12 1
    1 11 2
    2 10 3
    3 9 4
    4 8 5
    5 7 6
    6 6 7

    In the case shown in this example, the following combination is assumed:

    Number of digits of the company prefix: 6

    Number of digits of item reference: 7 If both items combined together do not form 13 digits, 0 is entered before the number to fill up the lacking number of digits.

    The partition value is 6, but since this value is generated within the PC, it need not be specified.


    Under this condition, if the format of <IPO> EPC code write is applied, it results in the following:

    When the standard format is used

    
    <IP0>e:h,enc:c,com:003885,itm:4006606,flt:0,srl:000000000001;
     

    Description of each parameter

    Code Explanation
    e:h,
    Specifies the standard format
    enc:c,
    Specifies SGTIN96 code conversion
    com:003885,
    The company prefix is 6 digits
    itm:4006606,
    The item reference is 7 digits 13 digits when combined with com:
    flt:0,
    The filter value is All Others
    srl:000000000001
    Serial number, fixed at 12 digits 274877906943 or a smaller number.
    ;
    End terminal

    When these commands are executed, the above parameters are converted to SGTIN96 code 301803CB4F48B38000000001 and 24 characters, and are written in a tag.

  10. GRAI96 code conversion

    This function generates a code according to the GRAI96 standard when you enter a company prefix, asset type, filter value, and serial number. We will explain how to use it by assuming the following numbers are given. All numbers below are decimal numbers.

    Company prefix:4912345

    Asset type:12345

    Filter value:0(All Others)

    Serial number:1002348

    The number of digits for the asset type varies depending on the length of the company prefix, as shown in the table below.

    Partition value Number of digit of the company prefix Number of digit of the asset type
    0 12 0
    1 11 1
    2 10 2
    3 9 3
    4 8 4
    5 7 5
    6 6 6

    In the case shown in this example, the following combination is assumed:
    Number of digits of the company prefix: 7
    Number of digits of the asset type: 5
    The partition value is 5, but since this value is generated within the PC, it need not be specified.


    Under this condition, if the format of <IP0> EPC code write is applied, it results in the following:

    When the standard format is used

    
    <IP0>e:h,enc:d,com:4912345,ast:12345,flt:0,srl:1002348;
     

    Description of each parameter

    Code Explanation
    e:h,
    Specifies the standard format
    enc:d,
    Specifies GRAI96 code conversion
    com:4912345,
    The company prefix is 7 digits
    ast:12345,
    The asset type is 5 digits 12 digits when combined with com:
    flt:0,
    The filter value is All Others
    srl:1002348
    Serial number, maximum 12 digits 274877906943 or a smaller number.
    ;
    End terminal

    When these commands are executed, the above parameters are converted to GRAI96 code 33152BD3640C0E40000F4B6C and 24 characters, and are written in a tag.

  11. GIAI96 code conversion

    This function generates a code according to the GIAI96 standard when you enter a company prefix, individual asset management number, filter value, and serial number. We will explain how to use it by assuming the following numbers are given. All numbers below are decimal numbers.

    Company prefix:4912345

    Individual asset management number:000000001234567890

    Filter value:0(All Others)

    The number of digits for the individual asset management number varies depending on the length of the company prefix, as shown in the table below.

    Partition value Number of digit of the company prefix Number of digit of the individual asset management number
    0 12 13
    1 11 14
    2 10 15
    3 9 16
    4 8 17
    5 7 18
    6 6 19

    In the case shown in this example, the following combination is assumed:
    Number of digits of the company prefix:7
    Number of digits of the individual asset management number:18
    The partition value is 5, but since this value is generated within the PC, it need not be specified.


    Under this condition, if the format of <IP0> EPC code write is applied, it results in the following:

    When the standard format is used

    
    <IP0>>e:h,enc:e,com:4912345,ast:000000001234567890,flt:0;
     

    Description of each parameter

    Code Explanation
    e:h,
    Specifies the standard format
    enc:e,
    Specifies GIAI96 code conversion
    com:4912345,
    The company prefix is 7 digits
    ast:000000001234567890,
    The individual asset management number is 18 digits 25 digits when combined with com:
    flt:0,
    The filter value is All Others
    ;
    End terminal

    When these commands are executed, the above parameters are converted to GIAI96 code 34152BD364000000499602D2 and 24 characters, and are written in a tag.