[ESC+IP5] Antenna Output Power (UHF)
HEX code
| ESC | <1B>16 |
|---|---|
| IP5 | <49>16<50>16<35>16 |
Parameter
aaa(,bbb)
Default Value
aaa=150 (x0.1dBm), bbb=150 (x0.1dBm)
Valid range and term of command
| When turning off the power switch | The set command is maintained. |
| Valid range within item | The set parameter becomes valid. |
| Valid range between items | The set parameter becomes valid. |
Function
This command specifies the antenna output power.
The antenna output power for the write command and the antenna output power for the read command can be set to separate values.
Format
<IP5>aaa(,bbb)
-
Parameters
aaa [Antenna output power for the write command] = Valid range: Refer to the table below
bbb [Antenna output power for the read command] = Valid range: Refer to the table below (Omissible)
If you specify only aaa, the antenna output power is set with both the write command and read command having the same value.
When both aaa and bbb are specified, the antenna output power setting is made by using the value of aaa for the write command and the value of bbb for the read command.
For details on the actual antenna output power, refer to the antenna output power setting table.
Parameter Valid Range
| Model | Region | Valid Range (A 3-digit number that is 10 times the dBm value) |
|---|---|---|
| CL4NX/CL6NX | - | 000 to 240 |
| CL4NX/CL6NX Plus CL4-SXR/CL6-SXR |
Japan | 000 to 240 |
| Indonesia 2 | 000 to 260 | |
| Singapore | 000 to 270 | |
| Vietnam | ||
| Philippines | ||
| Taiwan | ||
| Russian Federation | ||
| Other | 000 to 300 | |
| S84NX/S86NX | Japan | 000 to 240 |
| Indonesia | 000 to 260 | |
| Singapore | 000 to 270 | |
| Vietnam | ||
| Philippines | ||
| Taiwan | ||
| Russian Federation | ||
| Other | 000 to 300 | |
| CT4-LX | Japan | 000 to 240 |
| Indonesia | 000 to 260 | |
| Other | 000 to 270 |
Coding Example 1
<A>
<IP5>170
<Z>
Antenna power will be set to 17.0 dBm for both write and read commands without having to reboot the printer. This value will be maintained after power is switched off.
<A>
<IP5>120,090
<Z>
The antenna output power of the write command is changed to 12.0 dBm, and the antenna output power of the read command is changed to 9.0 dBm without restarting the printer. These settings are maintained after turning off the printer.
Supplemental explanation
- This command cannot be used in combination with other than <A> and <Z>.
- <IP5> Send the command when the printer stops printing and the printing items are not available in the printer.
- <IP5> In a case of sending a command, try to send it only one time when the RFID label
type is changed.
<IP5> In a case of sending a command in multiple times, encoding may not be correctly executed. - Since the antenna output power changes, it may not be possible to read or write some tags depending on their type.
- If you specify a value outside the range of parameters, a command error occurs.
- 150 is the default at shipping for both write and read commands.
- [DC2] The same setting can be selected by PA command but the radio output can be changed without restarting the printer by <IP5> command.
- While a value Valid Range can be recorded in the nonvolatile memory of the printer, the units place is rounded off to 0 during transmission to the reader/writer module.
- A number that is less than 100 is set to three digits by supplementing with a zero in the high order digit.
- In CL4NX/CL6NX Plus series, CL4-SXR/CL6-SXR, CT4-LX and S84NX/S86NX, if 25 dBm or more is set when the Japan region is specified, a command error will occur.
- In CL4NX/CL6NX Plus series, CL4-SXR/CL6-SXR, if 27 dBm or more is set when Indonesia 2 region is specified, a command error will occur.
- In CT4-LX and S84NX/S86NX, if 27 dBm or more is set when Indonesia region is specified, a command error will occur.
- In the CL4NX/CL6NX Plus series, CL4-SXR/CL6-SXR and S84NX/S86NX, if 28 dBm or more is set when the region is specified as Singapore, Vietnam, Philippines, Russia, or Taiwan, a command error will occur.
- In a case of sending a command, try to send it only one time when the RFID label type is
changed.
In a case of sending a command in multiple times, encoding may not be correctly executed.
Antenna output power table
| Parameter aaa |
Antenna output power (dBm) | Antenna output power (mW) | Parameter aaa |
Antenna output power (dBm) | Antenna output power (mW) |
|---|---|---|---|---|---|
| 0 to 9 | 0 | 1.0 | 160 to 169 | 16.0 | 39.8 |
| 10 to 19 | 1.0 | 1.2 | 170 to 179 | 17.0 | 50.1 |
| 20 to 29 | 2.0 | 1.5 | 180 to 189 | 18.0 | 63.0 |
| 30 to 39 | 3.0 | 1.9 | 190 to 199 | 19.0 | 79.4 |
| 40 to 49 | 4.0 | 2.5 | 200 to 209 | 20.0 | 100.0 |
| 50 to 59 | 5.0 | 3.1 | 210 to 219 | 21.0 | 125.8 |
| 60 to 69 | 6.0 | 3.9 | 220 to 229 | 22.0 | 158.4 |
| 70 to 79 | 7.0 | 5.0 | 230 to 239 | 23.0 | 199.5 |
| 80 to 89 | 8.0 | 6.3 | 240 to 249 | 24.0 | 251.1 |
| 90 to 99 | 9.0 | 7.9 | 250 to 259 | 25.0 | 316.2 |
| 100 to 109 | 10.0 | 10.0 | 260 to 269 | 26.0 | 398.1 |
| 110 to 119 | 11.0 | 12.5 | 270 to 279 | 27.0 | 501.1 |
| 120 to 129 | 12.0 | 15.8 | 280 to 289 | 28.0 | 630.9 |
| 130 to 139 | 13.0 | 19.9 | 290 to 299 | 29.0 | 794.3 |
| 140 to 149 | 14.0 | 25.1 | 300 | 30.0 | 1000 |
| 150 to 159 | 15.0 | 31.6 | |||
Note: While a value from 0 to 300 can be recorded in the nonvolatile memory of the printer, the units place is rounded off to 0 during transmission to the reader/writer module.
Example: Even when 199 is specified, actually, 19.0 dBm is set.