[ESC+RU] RFID Data Log Return (UHF) [NX/LX]
CL4NX
CL6NX
CL4NX-J
CL6NX-J
PW208/PW208m
PW208NX/PW208mNX
FX3-LX
CT4-LX/HC4-LX
PW4NX
LR4NX-FA
S84NX/S86NX
HEX code
| ESC | <1B>16 |
|---|---|
| RU | <52>16<55>16 |
Parameter
,aa
Default Value
aa=00
Valid range and term of command
| When turning off the power switch | The set command is not maintained. |
| Valid range within item | The set parameter is in effect until a new specification is made. |
| Valid range between items | The set parameter is in effect until a new specification is made. |
Function
This command is used to return EPC/TID/USER/PC/AFI together with the result when data is written to the RFID tag by the <IP0> command.
Format
Return specification: <RU>,aa
Request to return: [DC2]PK or [DC2]PJ
-
Parameters
Symbol Parameter name Valid range aa Identifier 00: Not returned (default setting)
01: Enable return data by sending [DC2]PK. Return data is obtained by sending [DC2]PK.
02: Enable return with [DC2]PJ. Return data is acquired by sending [DC2]PJ with LG option.
Two character fixation
Supplemental explanation
- <RU> and <TU> cannot be used together.
- <RU>,01 and <RU>,02 cannot be used in combination.
- If the RFID Data Log Return is enabled, it will take time to obtain the log, so please make sure that it does not affect the write operation.