[ESC+RU] RFID Data Log Return (UHF) [NX/LX]

CL4NX CL6NX CL4NX-J CL6NX-J PW208/PW208m PW208NX/PW208mNX FX3-LX CT4-LX/HC4-LX PW4NX LR4NX-FA S84NX/S86NX

HEX code

ESC <1B>16
RU <52>16<55>16

Parameter

,aa

Default Value

aa=00

Valid range and term of command

When turning off the power switch The set command is not maintained.
Valid range within item The set parameter is in effect until a new specification is made.
Valid range between items The set parameter is in effect until a new specification is made.

Function

This command is used to return EPC/TID/USER/PC/AFI together with the result when data is written to the RFID tag by the <IP0> command.

Format

Return specification: <RU>,aa

Request to return: [DC2]PK or [DC2]PJ

  • Parameters

    Symbol Parameter name Valid range
    aa Identifier

    00: Not returned (default setting)

    01: Enable return data by sending [DC2]PK. Return data is obtained by sending [DC2]PK.

    02: Enable return with [DC2]PJ. Return data is acquired by sending [DC2]PJ with LG option.

    Two character fixation
Supplemental explanation
  1. <RU> and <TU> cannot be used together.
  2. <RU>,01 and <RU>,02 cannot be used in combination.
  3. If the RFID Data Log Return is enabled, it will take time to obtain the log, so please make sure that it does not affect the write operation.

Example of returns

  • Refer to [DC2+PK] RFID Data Log Return Request (UHF) for return examples, etc.