[ESC+TU] RFID Printing Tag Data (UHF)
HEX code
| ESC | <1B>16 |
|---|---|
| TU | <54>16<55>16 |
Parameter
a(,bbcccddd n...n)
Default Value
Nil
Valid range and term of command
| When turning off the power switch | The set command is not maintained. |
| Valid range within item | The set parameter is in effect until a new specification is made. |
| Valid range between items | The set parameter becomes invalid. |
Function
Reads data from RFID tag and develops to specified direction to make it possible to print on label.
Format
<TU>a(,bbcccdddn...n)
-
Parameters
a = To use this functionality or not
1: Read data and start using
0: Cancel use
bb = Block number
01: EPC area
02: TID area
03: USER area
ccc = Start address of memory (HEX)
ddd = End address of memory (HEX)
The amount of information per one address is 2 bytes (4 characters) in case of Gen2.
An RFID tag error occurs if you specify an address that exceeds tag capacity.
The difference between "Start address of memory" and "End address of memory" shall be kept within 7 because the maximum amount of read data is 32 characters.
n = Specify ID. Specify any string within 4 to 16 characters to be used for assigning data.
(All parameters should be in the ASCII format)
Note:
- This command cannot be used to obtain CRC/PC in the EPC area. Use hexadecimal (02H as "0") to point to the address in the EPC area. See also "Gen2 standard, RFID chip memory map" below.
- 1 address = one word (16 bits), which is equivalent to 4 characters.

Coding Sample 1
A sample specifying 32 digits from start address 00 to end address 07 in EPC area of Gen2 tag, using SATO as ID. (Amount of information per 1 address: 4 characters)
<A>
<TU>1,01000007SATO
<%>0
<V>0410
<H>0090
<P>00
<L>0101
<XM>SATO
<%>0
<V>0060
<H>0040
<D>102120*SATO*
<%>0
<V>0195
<H>0055
<P>00
<L>0101
<XM>*SATO*
<%>1
<V>0595
<H>0520
<D>101060*SATO*
<TU>0
<%>1
<V>0595
<H>0035
<P>00
<L>0101
<XM>SATO
<Q>00001
<Z>

Coding Sample 2
Sample specifying 16 digits from start address 02h to end address 05h in the USER area (03) on Gen2 tag, using SATO as ID. (Amount of information per 1 address: 4 characters)
<A>
<TU>1, 03002005SATO
<%>0
<V>0410
<H>0090
<P>00
<L>0101
<XM>>SATO
<%>0
<V>0060
<H>0040
<D>102120*SATO*
<%>0
<V>0195
<H>0055
<P>00
<L>0101
<XM>*SATO*
<%>1
<V>0595
<H>0520
<D>101060*SATO*
<TU>0
<Q>00001
<Z>
Valid command
Font
<X20>
<X21>
<X22>
<X23>
<X24>
<XM>
<XS>
<XU>
<XB>
<XL>
<RH>
<$>
<$=>
<RD>
<U>
<S>
<M>
<WB>
<WL>
<OA>
<OB>
Barcode
<B>
<BC>
<BG>
<BZ>
<D>
<BD>
<2D10>
<2D12>
<2D20>
<2D30>
<2D31>
<2D50>
<DN>
<DS>
Command that cannot use in combination with
Command that associated with reediting
<F>
<(>
<&>
</>
<0>
<WD>
<PZ>
<RM>
Registration
<&S>
<&R>
<YS>
</N>
<YR>
</D>
Supplemental explanation
- If you specify reading data and start use (<TU>1), specify cancel use (<TU>0) within the same print job if.
- Only one pair of this command (<TU>1, <TU>0) can be specified in one print job.
- You cannot specify multiple labels for print jobs that include this command. Even if you specify 2 or more labels with <Q> command, it will be interpreted as 1.
- If more than one <TU>1 exists in the same item or more than one <TU>0 exists after <TU>1, a command error will occur.(Supported on CL4NX/CL6NX 1.15.6 or later, CT4-LX/HC4-LX 6.7.4 or later, S84NX/S86NX 8.2.1 or later, CL4-SXR/CL6-SXR. Other models aren't supported.)
- In the de-utilization (<TU>0) command, the inclusion of the (,) later will result in a command error.
- This command cannot be used in combination with other RFID commands.
-
When you specify the user ID by using <DN> in the data part during the use of 2D codes, specify the number of characters of the user ID in the number of data items.
Example: <TU>1,01000007SATO
<DN>0004,SATO - This command will not be executed while the printer is printing. It will be executed after the print is complete.
- This command is enabled in sequential printing, cutter (motion 1), dispenser (motion 1).
It is not available when in Tear-off mode, cutter mode (motion 2) and dispenser mode (motion 2). - This command will not work correctly if the tag offset is set anywhere other than default position.
In particular, sending this command with the tag offset set to a negative value and the 'Encoding Action' set to 'Normal Action' is considered a command error because of the high possibility of risk to the operation.(CL4NX/CL6NX 1.15.6 or later, CT4-LX/HC4-LX 6.7.4 or later, S84NX/S86NX 8.2.0 or later, CL4-SXR/CL6-SXR; Other models aren't supported.) - In case if tag data could not be read, error message will be printed and will retry with the next label or discard depending on the retry/release setting.
- This command does not support reprinting with reprint command<C>, external reprint signal or reprint key.
- The barcode types allowed in <B> (ratio 1:3) are "1: CODE39", "C: CODE93", and "G: CODE128". In addition, the only barcode type allowed in <D> (ratio 1:2) and <BD> (ratio 2:5) is "1: CODE39".
- QR code <2D30>, <2D31> are available, but they cannot be specified in numerical mode and Kanji mode. Micro QR code are not available due to limitations in the number of data.
- The maximum number of print elements (valid commands that include ID) to be converted for this command is 20. Avoid exceeding this maximum. When exceeded, the exceeded print element may become erroneous data.
- For valid command with limited digit number in target data, it is necessary to fill valid command with data if data obtained from RFID tag do not have enough digit number after it is specified by this command.
Example: <TU>1, 01000003SATO
<BC>020517SATO0 -
The available type of ANK character font with <RH> are as follows under the current specification:
SATO CG Sleek
SATO CG Stream
SATO OCRA
SATO 0
SATO ALPHABC
SATO BETABI
SATO FOLIOB
SATO FUTURAMC
SATO GAMMA
SATO OCRB
SATO SANS
SATO SERIF
SATO VICA