[ESC+/A] Air Protocols Management

CL4NX CL6NX CL4NX-J CL6NX-J PW208/PW208m PW208NX/PW208mNX FX3-LX CT4-LX/HC4-LX PW4NX LR4NX-FA S84NX/S86NX CL4-SXR CL6-SXR

Hexadecimal code

ESC <1B>16
/A <2F>16<41>16

Parameter

,a,b

Initial value

a = 0

Valid range and term of command

When the power switch is OFF The set parameter is maintained.
Valid range within items The set parameter becomes invalid.
Valid range between items The set parameter becomes invalid.

Function

To set the type of Air Protocols to be used and get the information about supported Air Protocols

Format

</A>,a,b

  • Parameter

    a [Air Protocol management]

    = 0: Get a list of all the supported Air Protocols

    = 1: Get the type of Air Protocol which is in used

    = 2: Set the type of Air Protocol to be used


    b [RFID options to be used]

    = 0: set "EPC Class 0+" (Not supported)

    = 1: set "EPC Class 1" (Not supported)

    = 2: set "GEN 2"

    = 3: set "EPC Class 1.19 (UCODE)" (Not supported)

    This parameter b is needed when a = 2 was specified.

Coding Example

Get the type of Air Protocol which is in used.


<A>
</A>,1
<Z>
                    

Set the type of Air Protocol to "EPC Class 1".


<A>
</A>,2,1
<Z>
                    

Supplementary Explanation

  1. To avoid incorrect response from printer, this command should not use in conjunction with other commands.
  2. Parameter 'a' will be set as '0' if not assigned.
  3. Air Protocol setting by "</A>,2,b" is maintained until next changes is made in LCD panel or "</A>,2,b" command again.
  4. For (a=2), the command will become invalid if the parameter 'b' is not assigned or assigned wrong reference number. (Note: Depending on the RFID modules, the command will become invalid if user set the RFID option that is not supported by module.)
  5. For (a=0), the character ',' (HEX: 2C) will act as separators between each reply Air Protocol. (Note: No separator will be used, if there is only one supported Air Protocol.)
  6. For (a=0), user cannot send any request command to the printer until the printer finished sending the requested data.
  7. Gen2 protocol is the only protocol setting supported currently, if other protocols were specify, it will return as a command error.