[ESC+/R] Remove Print Template
CL4NX
CL6NX
CL4NX-J
CL6NX-J
PW208/PW208m
PW208NX/PW208mNX
FX3-LX
CT4-LX/HC4-LX
PW4NX
LR4NX-FA
S84NX/S86NX
CL4-SXR
CL6-SXR
Hexadecimal code
| ESC | <1B>16 |
|---|---|
| /R | <2F>16<52>16 |
Parameter
,a,n...n
Initial value
a = 0
Valid range and term of command
| When the power switch is OFF | The set parameter is maintained. |
| Valid range within items | The set parameter becomes invalid. |
| Valid range between items | The set parameter becomes invalid. |
Function
To clear content registered XML print template inside printer memory
Format
</R>,a,n...n
- Parameter
a [Remover template]
= 0: Represent by print template name
= 1: Represent by print template format number
n...n [Print template name or format number]
= Valid range (Template name): 1 to 32 ASCII characters
= Valid range (Format number): 001 to 999
Coding Example
Clear Print Template with the template name "SATO Barcode".
<A>
<CC>1
</R>,0,SATO Barcode
<Z>
Supplementary Explanation
- To avoid incorrect response from printer, this command should not use in conjunction with other commands.
- This command is valid only when the desired template is registered inside the printer memory initially.
- When parameter (n...n) is not inserted or inserted wrong reference name, this </R> command will become invalid and the command is not effected.
- Parameter 'a' will be set as '0' if not assigned.
- Printer will be response "ACK" back to host PC if operation success, else printer will be response "NAK" to the host PC if operation fail.