[DC2+DT] State of the Display
CL4NX
CL6NX
CL4NX-J
CL6NX-J
PW208/PW208m
PW208NX/PW208mNX
FX3-LX
CT4-LX/HC4-LX
PW4NX
LR4NX-FA
S84NX/S86NX
CL4-SXR
CL6-SXR
HEX code
| DC2 | <12>16 |
|---|---|
| DT |
<44>16<54>16 |
Parameter
,a,b
Default Value
Normal display, backlight normally lit
Valid range and term of command
| When turning off the power switch | The setting status is not saved. |
| Valid range | Setting state, while power is being supplied is valid until the next set. |
| Printer operation in progress | The command cannot be received during the printer operation. ([NAK] return) |
| Error | Commands can be received even if an error is occurring. |
| Unauthentication | Commands can be received even if authentication is not in progress using the [DC2+PS] command. |
Function
Set the LCD display status of the printer. (S84NX/S86NX: One LCD function)
Format
[DC2]DT,a,b
Parameters: S84NX/S86NX
| Symbol | Parameter name | Valid range | Acquisition method |
|---|---|---|---|
| a | Specifying Display | 0: Normal display 1: Reservations (specify invalid) |
One character fixed acquisition |
| b | Backlight designation | 0: normally lit 1: off 2: Lights up when an error occurs |
One character fixed acquisition |
Return data format (normal)
[ACK]<06>16
Return data format (when a command error occurs)
[NAK]<15>16
Exception processing
| Parameter name | Exception condition: A value outside the range is specified |
Exception condition: When it cannot be executed |
|---|---|---|
| Specifying Display | Command error | Command error |
| Backlight designation | Command error | Command error |
| Terminology | Description |
|---|---|
| Command error | The data received after a command error is determined is not considered as a parameter of this command. |
Supplementary Explanation
- When using the screenshot printer display of another command, select "0: Normal display" for the
display.
(If the screenshot is implemented)