HEX code

DC2 <12>16
DT

<44>16<54>16

Parameter

,a,b

Default Value

Normal display, backlight normally lit

Valid range and term of command

When turning off the power switch The setting status is not saved.
Valid range Setting state, while power is being supplied is valid until the next set.
Printer operation in progress The command cannot be received during the printer operation. ([NAK] return)
Error Commands can be received even if an error is occurring.
Unauthentication Commands can be received even if authentication is not in progress using the [DC2+PS] command.

Function

Set the LCD display status of the printer. (S84NX/S86NX: One LCD function)

Format

[DC2]DT,a,b

Parameters: S84NX/S86NX

Symbol Parameter name Valid range Acquisition method
a Specifying Display 0: Normal display
1: Reservations (specify invalid)
One character fixed acquisition
b Backlight designation 0: normally lit
1: off
2: Lights up when an error occurs
One character fixed acquisition

Return data format (normal)

[ACK]<06>16

Return data format (when a command error occurs)

[NAK]<15>16

Exception processing

Parameter name Exception condition:
A value outside the range is specified
Exception condition:
When it cannot be executed
Specifying Display Command error Command error
Backlight designation Command error Command error

Terminology Description
Command error The data received after a command error is determined is not considered as a parameter of this command.

Supplementary Explanation

  1. When using the screenshot printer display of another command, select "0: Normal display" for the display.