[COUNT] Section
CL4NX/CL4NX-J/CL6NX/CL6NX-J
| Name of Setting item | Setting value | Default Value | R/W | Initial: CB | Contents of Setting item |
|---|---|---|---|---|---|
|
PRTCLN |
"0": Disable "1": Enable |
0 |
R/W |
Yes |
Notification for printer cleanup |
|
PRTCLN_ITV_COUNT |
"10" to "1000" (m) |
400 |
R/W |
Yes |
Distance to display notification for printer cleanup |
|
PRTCLN_COUNT |
"XXXX" (unit)* |
- |
R |
No |
Cleaning distance *
24 units = 1 mm |
|
HDCHG |
"0": Disable "1": Enable |
0 |
R/W |
Yes |
Notification for replacing thermal head |
|
HDCHG_ITV_COUNT |
"10" to "100" (km) |
100 |
R/W |
Yes |
Distance to display notification for replacing thermal head |
|
HDCHG_COUNT |
"XXX" (unit)* |
- |
R |
No |
Print distance of a thermal head *
24 units = 1 mm |
|
CUTUNT |
"0": Disable "1": Enable |
0 |
R/W |
Yes |
Notification for replacing cutter unit |
|
CUTUNT_ITV_COUNT |
"10" to "1000" (thousand cuts) |
1000 |
R/W |
Yes |
Distance to display notification for replacing cutter unit |
|
CUTUNT_COUNT |
"XX" |
- |
R |
No |
Cut count |
|
ROLLER |
"0": Disable "1": Enable |
0 |
R/W |
Yes |
Notification for replacing platen roller |
|
ROLLER_ITV_COUNT |
"10" to "100" (km) |
100 |
R/W |
Yes |
Distance to display notification for replacing platen roller |
|
ROLLER_COUNT |
"XXX" (unit)* |
- |
R |
No |
Distance of the platen roller *
24 units = 1 mm |
PW2 Series
| Name of Setting item | Setting value | Default Value | R/W | Initial: CB | Contents of Setting item |
|---|---|---|---|---|---|
|
PRTCLN |
"0": Disable "1": Enable |
0 |
R/W |
Yes |
Notification for printer cleanup |
|
PRTCLN_ITV_COUNT |
"10" to "1000" (m) |
150 |
R/W |
Yes |
Distance to display notification for printer cleanup |
|
PRTCLN_COUNT |
"XXXX" (unit)* |
- |
R |
No |
Cleaning distance *
8 units = 1 mm |
|
HDCHG |
"0": Disable "1": Enable |
0 |
R/W |
Yes |
Notification for replacing thermal head |
|
HDCHG_ITV_COUNT |
"10" to "100" (km) |
30 |
R/W |
Yes |
Distance to display notification for replacing thermal head |
|
HDCHG_COUNT |
"XXX" (unit)* |
- |
R |
No |
Print distance of a thermal head *
8 units = 1 mm |
|
ROLLER |
"0": Disable "1": Enable |
0 |
R/W |
Yes |
Notification for replacing platen roller |
|
ROLLER_ITV_COUNT |
"10" to "100" (km) |
30 |
R/W |
Yes |
Distance to display notification for replacing platen roller |
|
ROLLER_COUNT |
"XXX" (unit)* |
- |
R |
No |
Distance of the platen roller *
8 units = 1 mm |
|
BATTERY_CYCLE_COUNT |
"XXX" |
- |
R |
No |
Battery cycle count |
PW4NX Series
| Name of Setting item | Setting value | Default Value | R/W | Initial: CB | Contents of Setting item |
|---|---|---|---|---|---|
|
PRTCLN |
"0": Disable "1": Enable |
0 |
R/W |
Yes |
Notification for printer cleanup |
|
PRTCLN_ITV_COUNT |
"10" to "1000" (m) |
25 |
R/W |
Yes |
Distance to display notification for printer cleanup |
|
PRTCLN_COUNT |
"XXXX" (unit)* |
- |
R |
No |
Distance to clear printer *
8 units = 1 mm |
|
HDCHG |
"0": Disable "1": Enable |
0 |
R/W |
Yes |
Notification for replacing thermal head |
|
HDCHG_ITV_COUNT |
"10" to "100" (km) |
30 |
R/W |
Yes |
Distance to display notification for replacing thermal head |
|
HDCHG_COUNT |
"XXX" (unit)* |
- |
R |
No |
Distance of thermal head *
8 units = 1 mm |
|
ROLLER |
"0": Disable "1": Enable |
0 |
R/W |
Yes |
Notification for replacing platen roller |
|
ROLLER_ITV_COUNT |
"10" to "100" (km) |
30 |
R/W |
Yes |
Distance to display notification for replacing platen roller |
|
ROLLER_COUNT |
"XXX" (unit)* |
- |
R |
No |
Distance to display notification for replacing platen roller *
8 units = 1 mm |
|
BATTERY_CYCLE_COUNT |
"XXX" |
- |
R |
No |
Battery cycle count |
FX3-LX Series
| Name of Setting item | Setting value | Default Value | R/W | Initial: CB | Contents of Setting item |
Support *Yes: Support No: Not Support |
|---|---|---|---|---|---|---|
|
PRTCLN |
"0": Disable "1": Enable |
0 |
R/W |
Yes |
Notification for printer cleanup |
Int'l: Yes Japan: No |
|
PRTCLN_ITV_COUNT |
"10" to "1000" (m) |
400 |
R/W |
Yes |
Distance to display notification for printer cleanup |
Int'l: Yes Japan: No |
|
PRTCLN_COUNT |
"XXXX" (unit)* |
- |
R |
No |
Distance to clear printer *
12 units = 1 mm |
Int'l: Yes Japan: No |
|
HDCHG |
"0": Disable "1": Enable |
0 |
R/W |
Yes |
Notification for replacing thermal head |
Int'l: Yes Japan: No |
|
HDCHG_ITV_COUNT |
"10" to "100" (km) |
100 |
R/W |
Yes |
Distance to display notification for replacing thermal head |
Int'l: Yes Japan: No |
|
HDCHG_COUNT |
"XXX" (unit)* |
- |
R |
No |
Distance of thermal head *
12 units = 1 mm |
Int'l: Yes Japan: No |
|
CUTUNT |
"0": Disable "1": Enable |
0 |
R/W |
Yes |
Notification for replacing cutter unit |
Int'l: Yes Japan: No |
|
CUTUNT_ITV_COUNT |
"10" to "1000" (thousand cuts) |
1000 |
R/W |
Yes |
Distance to display notification for replacing cutter unit |
Int'l: Yes Japan: No |
|
CUTUNT_COUNT |
"XX" |
- |
R |
No |
The number of cutter unit |
Int'l: Yes Japan: No |
|
ROLLER |
"0": Disable "1": Enable |
0 |
R/W |
Yes |
Notification for replacing platen roller |
Int'l: Yes Japan: No |
|
ROLLER_ITV_COUNT |
"10" to "100" (km) |
100 |
R/W |
Yes |
Distance to display notification for replacing platen roller |
Int'l: Yes Japan: No |
|
ROLLER_COUNT |
"XXX" (unit)* |
- |
R |
No |
Distance of platen roller *
12 units = 1 mm |
Int'l: Yes Japan: No |
|
BATTERY_CYCLE_COUNT |
"XXX" |
- |
R |
No |
Battery cycle count |
Int'l: Yes Japan: No |
CT4-LX/HC4-LX Series
| Name of Setting item | Setting value | Default Value | R/W | Initial: CB | Contents of Setting item |
|---|---|---|---|---|---|
|
PRTCLN |
"0": Disable "1": Enable |
0 |
R/W |
Yes |
Notification for printer cleanup |
|
PRTCLN_ITV_COUNT |
"10" to "1000" (m) |
400 |
R/W |
Yes |
Distance to display notification for printer cleanup |
|
PRTCLN_COUNT |
"XXXX" (unit)* |
- |
R |
No |
Distance to clear printer *
[203dpi] |
|
HDCHG |
"0": Disable "1": Enable |
0 |
R/W |
Yes |
Notification for replacing thermal head |
|
HDCHG_ITV_COUNT |
"10" to "100" (km) |
100 |
R/W |
Yes |
Distance to display notification for replacing thermal head |
|
HDCHG_COUNT |
"XXX" (unit)* |
- |
R |
No |
Distance of thermal head *
[203dpi] |
|
CUTUNT |
"0": Disable "1": Enable |
0 |
R/W |
Yes |
Notification for replacing cutter unit |
|
CUTUNT_ITV_COUNT |
"10" to "1000" (thousand cuts) |
1000 |
R/W |
Yes |
Distance to display notification for replacing cutter unit |
|
CUTUNT_COUNT |
"XX" |
- |
R |
No |
The number of cutter unit |
|
ROLLER |
"0": Disable "1": Enable |
0 |
R/W |
Yes |
Notification for replacing platen roller |
|
ROLLER_ITV_COUNT |
"10" to "100" (km) |
100 |
R/W |
Yes |
Distance to display notification for replacing platen roller |
|
ROLLER_COUNT |
"XXX" (unit)* |
- |
R |
No |
Distance of platen roller *
[203dpi] |
LR4NX-FA
| Name of Setting item | Setting value | Default Value | R/W | Initial: CB | Contents of Setting item |
|---|---|---|---|---|---|
|
PRTCLN |
"0": Disable "1": Enable |
0 |
R/W |
Yes |
Notification for printer cleanup |
|
PRTCLN_ITV_COUNT |
"10" to "1000" (m) |
400 |
R/W |
Yes |
Distance to display notification for printer cleanup |
|
PRTCLN_COUNT |
"XXXX" (unit)* |
- |
R |
No |
Cleaning distance *
24 units = 1 mm |
|
HDCHG |
"0": Disable "1": Enable |
0 |
R/W |
Yes |
Notification for replacing thermal head |
|
HDCHG_ITV_COUNT |
"10" to "100" (km) |
100 |
R/W |
Yes |
Distance to display notification for replacing thermal head |
|
HDCHG_COUNT |
"XXX" (unit)* |
- |
R |
No |
Print distance of a thermal head *
24 units = 1 mm |
|
ROLLER |
"0": Disable "1": Enable |
0 |
R/W |
Yes |
Notification for replacing platen roller |
|
ROLLER_ITV_COUNT |
"10" to "100" (km) |
100 |
R/W |
Yes |
Distance to display notification for replacing platen roller |
|
ROLLER_COUNT |
"XXX" (unit)* |
- |
R |
No |
Distance of the platen roller *
24 units = 1 mm |
S84NX/S86NX
| Name of Setting item | Setting value | Default Value | R/W | Initial: CB | Contents of Setting item |
|---|---|---|---|---|---|
|
PRTCLN |
"0": Disable "1": Enable |
0 |
R/W |
Yes |
Notification for printer cleanup |
|
PRTCLN_ITV_COUNT |
"10" to "1000" (m) |
400 |
R/W |
Yes |
Distance to display notification for printer cleanup |
|
PRTCLN_COUNT |
"XXXX" (unit)* |
- |
R |
No |
Cleaning distance *
24 units = 1 mm |
|
HDCHG |
"0": Disable "1": Enable |
0 |
R/W |
Yes |
Notification for replacing thermal head |
|
HDCHG_ITV_COUNT |
"10" to "100" (km) |
100 |
R/W |
Yes |
Distance to display notification for replacing thermal head |
|
HDCHG_COUNT |
"XXX" (unit)* |
- |
R |
No |
Print distance of a thermal head *
24 units = 1 mm |
|
ROLLER |
"0": Disable "1": Enable |
0 |
R/W |
Yes |
Notification for replacing platen roller |
|
ROLLER_ITV_COUNT |
"10" to "100" (km) |
100 |
R/W |
Yes |
Distance to display notification for replacing platen roller |
|
ROLLER_COUNT |
"XXX" (unit)* |
- |
R |
No |
Distance of the platen roller *
24 units = 1 mm |
|
BELTG |
"0": Disable "1": Enable |
0 |
R/W |
Yes |
Notification for replacing timing belt (gear box) |
|
BELTG_ITV_COUNT |
"10" to "300" (km) |
150 |
R/W |
Yes |
Distance to display notification for replacing timing belt (gear box) |
|
BELTG_COUNT |
"XXX" (unit)* |
- |
R |
No |
Distance of the timing belt (gear box) *
12 units = 1 mm |
|
BELTR |
"0": Disable "1": Enable |
0 |
R/W |
Yes |
Notification for replacing timing belt (ribbon) |
|
BELTR_ITV_COUNT |
"10" to "300" (km) |
150 |
R/W |
Yes |
Distance to display notification for replacing timing belt (ribbon) |
|
BELTR_COUNT |
"XXX" (unit)* |
- |
R |
No |
Distance of the timing belt (ribbon) *
12 units = 1 mm |
|
EXTNOTI1 |
"0": Disable "1": Enable |
0 |
R/W |
Yes |
Feature enhancement notification 1 Notification1 |
|
EXTNOTI1_ITV_COUNT |
"0" to "999" (km) |
150 |
R/W |
Yes |
Feature enhancement notification 1 Distance to display Notification1 |
|
EXTNOTI1_COUNT |
"XXX" (unit)* |
- |
R |
No |
Feature enhancement notification 1 (Life counter value when reset requested) *
24 units = 1 mm |
|
EXTNOTI2 |
"0": Disable "1": Enable |
0 |
R/W |
Yes |
Feature enhancement notification 2 Notification2 |
|
EXTNOTI2_ITV_COUNT |
"0" to "999" (km) |
150 |
R/W |
Yes |
Feature enhancement notification 2 Distance to display Notification2 |
|
EXTNOTI2_COUNT |
"XXX" |
- |
R |
No |
Feature enhancement notification 2 (Life counter value when reset requested) *
24 units = 1 mm |
|
EXTNOTI3 |
"0": Disable "1": Enable |
0 |
R/W |
Yes |
Feature enhancement notification 3 Notification3 |
|
EXTNOTI3_ITV_COUNT |
"0" to "999" (km) |
150 |
R/W |
Yes |
Feature enhancement notification 3 Distance to display Notification3 |
|
EXTNOTI3_COUNT |
"XXX" (unit)* |
- |
R |
No |
Feature enhancement notification 3 (Life counter value when reset requested) *
24 units = 1 mm |