[COUNT] Section

CL4NX/CL4NX-J/CL6NX/CL6NX-J

Name of Setting item Setting value Default Value R/W Initial: CB Contents of Setting item

PRTCLN

"0": Disable

"1": Enable

0

R/W

Yes

Notification for printer cleanup

PRTCLN_ITV_COUNT

"10" to "1000" (m)

400

R/W

Yes

Distance to display notification for printer cleanup

PRTCLN_COUNT

"XXXX" (unit)*

-

R

No

Cleaning distance

* 24 units = 1 mm
e.g. 120 units = 5 mm
Same logic applies to all resolutions for these models.

HDCHG

"0": Disable

"1": Enable

0

R/W

Yes

Notification for replacing thermal head

HDCHG_ITV_COUNT

"10" to "100" (km)

100

R/W

Yes

Distance to display notification for replacing thermal head

HDCHG_COUNT

"XXX" (unit)*

-

R

No

Print distance of a thermal head

* 24 units = 1 mm
e.g. 120 units = 5 mm
Same logic applies to all resolutions for these models.

CUTUNT

"0": Disable

"1": Enable

0

R/W

Yes

Notification for replacing cutter unit

CUTUNT_ITV_COUNT

"10" to "1000" (thousand cuts)

1000

R/W

Yes

Distance to display notification for replacing cutter unit

CUTUNT_COUNT

"XX"

-

R

No

Cut count

ROLLER

"0": Disable

"1": Enable

0

R/W

Yes

Notification for replacing platen roller

ROLLER_ITV_COUNT

"10" to "100" (km)

100

R/W

Yes

Distance to display notification for replacing platen roller

ROLLER_COUNT

"XXX" (unit)*

-

R

No

Distance of the platen roller

* 24 units = 1 mm
e.g. 120 units = 5 mm
Same logic applies to all resolutions for these models.

PW2 Series

Name of Setting item Setting value Default Value R/W Initial: CB Contents of Setting item

PRTCLN

"0": Disable

"1": Enable

0

R/W

Yes

Notification for printer cleanup

PRTCLN_ITV_COUNT

"10" to "1000" (m)

150

R/W

Yes

Distance to display notification for printer cleanup

PRTCLN_COUNT

"XXXX" (unit)*

-

R

No

Cleaning distance

* 8 units = 1 mm
e.g. 40 units = 5 mm

HDCHG

"0": Disable

"1": Enable

0

R/W

Yes

Notification for replacing thermal head

HDCHG_ITV_COUNT

"10" to "100" (km)

30

R/W

Yes

Distance to display notification for replacing thermal head

HDCHG_COUNT

"XXX" (unit)*

-

R

No

Print distance of a thermal head

* 8 units = 1 mm
e.g. 40 units = 5 mm

ROLLER

"0": Disable

"1": Enable

0

R/W

Yes

Notification for replacing platen roller

ROLLER_ITV_COUNT

"10" to "100" (km)

30

R/W

Yes

Distance to display notification for replacing platen roller

ROLLER_COUNT

"XXX" (unit)*

-

R

No

Distance of the platen roller

* 8 units = 1 mm
e.g. 40 units = 5 mm

BATTERY_CYCLE_COUNT

"XXX"

-

R

No

Battery cycle count

PW4NX Series

Name of Setting item Setting value Default Value R/W Initial: CB Contents of Setting item

PRTCLN

"0": Disable

"1": Enable

0

R/W

Yes

Notification for printer cleanup

PRTCLN_ITV_COUNT

"10" to "1000" (m)

25

R/W

Yes

Distance to display notification for printer cleanup

PRTCLN_COUNT

"XXXX" (unit)*

-

R

No

Distance to clear printer

* 8 units = 1 mm
e.g. 40 units = 5 mm

HDCHG

"0": Disable

"1": Enable

0

R/W

Yes

Notification for replacing thermal head

HDCHG_ITV_COUNT

"10" to "100" (km)

30

R/W

Yes

Distance to display notification for replacing thermal head

HDCHG_COUNT

"XXX" (unit)*

-

R

No

Distance of thermal head

* 8 units = 1 mm
e.g. 40 units = 5 mm

ROLLER

"0": Disable

"1": Enable

0

R/W

Yes

Notification for replacing platen roller

ROLLER_ITV_COUNT

"10" to "100" (km)

30

R/W

Yes

Distance to display notification for replacing platen roller

ROLLER_COUNT

"XXX" (unit)*

-

R

No

Distance to display notification for replacing platen roller

* 8 units = 1 mm
e.g. 40 units = 5 mm

BATTERY_CYCLE_COUNT

"XXX"

-

R

No

Battery cycle count

FX3-LX Series

Name of Setting item Setting value Default Value R/W Initial: CB Contents of Setting item Support
*Yes:
Support
No:
Not Support

PRTCLN

"0": Disable

"1": Enable

0

R/W

Yes

Notification for printer cleanup

Int'l:
Yes
Japan:
No

PRTCLN_ITV_COUNT

"10" to "1000" (m)

400

R/W

Yes

Distance to display notification for printer cleanup

Int'l:
Yes
Japan:
No

PRTCLN_COUNT

"XXXX" (unit)*

-

R

No

Distance to clear printer

* 12 units = 1 mm
e.g. 60 units = 5 mm

Int'l:
Yes
Japan:
No

HDCHG

"0": Disable

"1": Enable

0

R/W

Yes

Notification for replacing thermal head

Int'l:
Yes
Japan:
No

HDCHG_ITV_COUNT

"10" to "100" (km)

100

R/W

Yes

Distance to display notification for replacing thermal head

Int'l:
Yes
Japan:
No

HDCHG_COUNT

"XXX" (unit)*

-

R

No

Distance of thermal head

* 12 units = 1 mm
e.g. 60 units = 5 mm

Int'l:
Yes
Japan:
No

CUTUNT

"0": Disable

"1": Enable

0

R/W

Yes

Notification for replacing cutter unit

Int'l:
Yes
Japan:
No

CUTUNT_ITV_COUNT

"10" to "1000" (thousand cuts)

1000

R/W

Yes

Distance to display notification for replacing cutter unit

Int'l:
Yes
Japan:
No

CUTUNT_COUNT

"XX"

-

R

No

The number of cutter unit

Int'l:
Yes
Japan:
No

ROLLER

"0": Disable

"1": Enable

0

R/W

Yes

Notification for replacing platen roller

Int'l:
Yes
Japan:
No

ROLLER_ITV_COUNT

"10" to "100" (km)

100

R/W

Yes

Distance to display notification for replacing platen roller

Int'l:
Yes
Japan:
No

ROLLER_COUNT

"XXX" (unit)*

-

R

No

Distance of platen roller

* 12 units = 1 mm
e.g. 60 units = 5 mm

Int'l:
Yes
Japan:
No

BATTERY_CYCLE_COUNT

"XXX"

-

R

No

Battery cycle count

Int'l:
Yes
Japan:
No

CT4-LX/HC4-LX Series

Name of Setting item Setting value Default Value R/W Initial: CB Contents of Setting item

PRTCLN

"0": Disable

"1": Enable

0

R/W

Yes

Notification for printer cleanup

PRTCLN_ITV_COUNT

"10" to "1000" (m)

400

R/W

Yes

Distance to display notification for printer cleanup

PRTCLN_COUNT

"XXXX" (unit)*

-

R

No

Distance to clear printer

* [203dpi]
8 units = 1 mm
e.g. 40 units = 5 mm
[305dpi]
12 units = 1 mm
e.g. 60 units = 5 mm

HDCHG

"0": Disable

"1": Enable

0

R/W

Yes

Notification for replacing thermal head

HDCHG_ITV_COUNT

"10" to "100" (km)

100

R/W

Yes

Distance to display notification for replacing thermal head

HDCHG_COUNT

"XXX" (unit)*

-

R

No

Distance of thermal head

* [203dpi]
8 units = 1 mm
e.g. 40 units = 5 mm
[305dpi]
12 units = 1 mm
e.g. 60 units = 5 mm

CUTUNT

"0": Disable

"1": Enable

0

R/W

Yes

Notification for replacing cutter unit

CUTUNT_ITV_COUNT

"10" to "1000" (thousand cuts)

1000

R/W

Yes

Distance to display notification for replacing cutter unit

CUTUNT_COUNT

"XX"

-

R

No

The number of cutter unit

ROLLER

"0": Disable

"1": Enable

0

R/W

Yes

Notification for replacing platen roller

ROLLER_ITV_COUNT

"10" to "100" (km)

100

R/W

Yes

Distance to display notification for replacing platen roller

ROLLER_COUNT

"XXX" (unit)*

-

R

No

Distance of platen roller

* [203dpi]
8 units = 1 mm
e.g. 40 units = 5 mm
[305dpi]
12 units = 1 mm
e.g. 60 units = 5 mm

LR4NX-FA

Name of Setting item Setting value Default Value R/W Initial: CB Contents of Setting item

PRTCLN

"0": Disable

"1": Enable

0

R/W

Yes

Notification for printer cleanup

PRTCLN_ITV_COUNT

"10" to "1000" (m)

400

R/W

Yes

Distance to display notification for printer cleanup

PRTCLN_COUNT

"XXXX" (unit)*

-

R

No

Cleaning distance

* 24 units = 1 mm
e.g. 120 units = 5 mm
Same logic applies to all resolutions for these models.

HDCHG

"0": Disable

"1": Enable

0

R/W

Yes

Notification for replacing thermal head

HDCHG_ITV_COUNT

"10" to "100" (km)

100

R/W

Yes

Distance to display notification for replacing thermal head

HDCHG_COUNT

"XXX" (unit)*

-

R

No

Print distance of a thermal head

* 24 units = 1 mm
e.g. 120 units = 5 mm
Same logic applies to all resolutions for these models.

ROLLER

"0": Disable

"1": Enable

0

R/W

Yes

Notification for replacing platen roller

ROLLER_ITV_COUNT

"10" to "100" (km)

100

R/W

Yes

Distance to display notification for replacing platen roller

ROLLER_COUNT

"XXX" (unit)*

-

R

No

Distance of the platen roller

* 24 units = 1 mm
e.g. 120 units = 5 mm
Same logic applies to all resolutions for these models.

S84NX/S86NX

Name of Setting item Setting value Default Value R/W Initial: CB Contents of Setting item

PRTCLN

"0": Disable

"1": Enable

0

R/W

Yes

Notification for printer cleanup

PRTCLN_ITV_COUNT

"10" to "1000" (m)

400

R/W

Yes

Distance to display notification for printer cleanup

PRTCLN_COUNT

"XXXX" (unit)*

-

R

No

Cleaning distance

* 24 units = 1 mm
e.g. 120 units = 5 mm
Same logic applies to all resolutions for these models.

HDCHG

"0": Disable

"1": Enable

0

R/W

Yes

Notification for replacing thermal head

HDCHG_ITV_COUNT

"10" to "100" (km)

100

R/W

Yes

Distance to display notification for replacing thermal head

HDCHG_COUNT

"XXX" (unit)*

-

R

No

Print distance of a thermal head

* 24 units = 1 mm
e.g. 120 units = 5 mm
Same logic applies to all resolutions for these models.

ROLLER

"0": Disable

"1": Enable

0

R/W

Yes

Notification for replacing platen roller

ROLLER_ITV_COUNT

"10" to "100" (km)

100

R/W

Yes

Distance to display notification for replacing platen roller

ROLLER_COUNT

"XXX" (unit)*

-

R

No

Distance of the platen roller

* 24 units = 1 mm
e.g. 120 units = 5 mm
Same logic applies to all resolutions for these models.

BELTG

"0": Disable

"1": Enable

0

R/W

Yes

Notification for replacing timing belt (gear box)

BELTG_ITV_COUNT

"10" to "300" (km)

150

R/W

Yes

Distance to display notification for replacing timing belt (gear box)

BELTG_COUNT

"XXX" (unit)*

-

R

No

Distance of the timing belt (gear box)

* 12 units = 1 mm
e.g. 60 units = 5 mm
Same logic applies to all resolutions for these models.

BELTR

"0": Disable

"1": Enable

0

R/W

Yes

Notification for replacing timing belt (ribbon)

BELTR_ITV_COUNT

"10" to "300" (km)

150

R/W

Yes

Distance to display notification for replacing timing belt (ribbon)

BELTR_COUNT

"XXX" (unit)*

-

R

No

Distance of the timing belt (ribbon)

* 12 units = 1 mm
e.g. 60 units = 5 mm
Same logic applies to all resolutions for these models.

EXTNOTI1

"0": Disable

"1": Enable

0

R/W

Yes

Feature enhancement notification 1

Notification1

EXTNOTI1_ITV_COUNT

"0" to "999" (km)

150

R/W

Yes

Feature enhancement notification 1

Distance to display Notification1

EXTNOTI1_COUNT

"XXX" (unit)*

-

R

No

Feature enhancement notification 1
Mileage to display Notification

(Life counter value when reset requested)

* 24 units = 1 mm
e.g. 120 units = 5 mm
Same logic applies to all resolutions for these models.

EXTNOTI2

"0": Disable

"1": Enable

0

R/W

Yes

Feature enhancement notification 2

Notification2

EXTNOTI2_ITV_COUNT

"0" to "999" (km)

150

R/W

Yes

Feature enhancement notification 2

Distance to display Notification2

EXTNOTI2_COUNT

"XXX"

-

R

No

Feature enhancement notification 2
Mileage to display Notification

(Life counter value when reset requested)

* 24 units = 1 mm
e.g. 120 units = 5 mm
Same logic applies to all resolutions for these models.

EXTNOTI3

"0": Disable

"1": Enable

0

R/W

Yes

Feature enhancement notification 3

Notification3

EXTNOTI3_ITV_COUNT

"0" to "999" (km)

150

R/W

Yes

Feature enhancement notification 3

Distance to display Notification3

EXTNOTI3_COUNT

"XXX" (unit)*

-

R

No

Feature enhancement notification 3
Mileage to display Notification

(Life counter value when reset requested)

* 24 units = 1 mm
e.g. 120 units = 5 mm
Same logic applies to all resolutions for these models.