[RFID] Section

CL4NX/CL4NX-J/CL6NX/CL6NX-J

Name of Setting item Setting value Default Value R/W Initial: IF Contents of Setting item

RFID_LIFE_COUNT_SUCCESS

"0" to "999999"

0

R

No

RFID success count of life

SOH+RB

RFID_LIFE_COUNT_FAILURE

"0" to "999999"

0

R

No

RFID failure count of life

SOH+RB

RFID_LIFE_COUNT_TOTAL

"0" to "999999"

0

R

No

RFID print count of life

SOH+RB

RFID_COUNT_SUCCESS

"0" to "999999"

0

R

Yes

RFID success count

SOH+RB

RFID_COUNT_FAILURE

"0" to "999999"

0

R

Yes

RFID failure count

SOH+RB

RFID_COUNT_TOTAL

"0" to "999999"

0

R

Yes

RFID print count

SOH+RB

CLEAR_RFID_COUNT

"0": Disable

"1": Enable

0

W

Yes

RFID counter clear

<RA>2,Rc:

READER_MODEL

"XXXXXXXXXXXXXXXX"

-

R

No

Model of reader

READER_VERSION

"XXXXXXXXXXXXXXXX"

-

R

No

Version of reader

RFID_PITCH

[CL4NX/CL6NX UHF]

"0": STANDARD

"1": SMALL

[CL4NX/CL6NX Plus UHF]

"0": Normal

"1": Front

[HF]

"0": Forward

"1": Center

"2": Backward

0

R/W

Yes

RFID antenna pitch

* Only when RFID is valid

Reboot is required after setting.

RFID_LABEL_DATA

"0": RETRY

"1": RELEASE

0

R/W

Yes

RFID Retry mode

<RA>2,Ed:

MAX_RETRY_LABEL

"0" to "9"

1

R/W

Yes

RFID Retry print

<RA>2,Ec:

MAX_RETRY_COUNT

"0" to "9"

4

R/W

Yes

RFID Retry count

<RA>2,Rt:

RFID_ERROR_SLASH

"0": Disable

"1": Enable

1

R/W

Yes

RFID Error slanted line printing

<RA>2,Es:

RFID_TAG_OFFSET

"-15" to "240" mm

"-15" to "15" mm (When [Encoding Action] is "Feed Action". See below (*1) for detail.)

If the current print operation mode (refer to [Printing]-[Print Mode]) is not "Continuous", the minimum value is 0.
cf.[PRINTER] section PRINT_AUTO and PRINT

  1. When the value specified in command is set to 16 mm to 240 mm, [Encoding Action] is forced to ["0": Normal Action] even if "Encoding Action" is ["1": Feed Action].

Constraints at minus tag offset:

If [Tag Offset]: RFID_TAG_OFFSET is set to -1mm or less when [Encoding Action] ]: ENCODING_ACTION is set to [Normal Action], [Pitch Size] must be specified accurately.

Please set the exact pitch size in [Pitch Size]: SRA_LABEL_PITCH.

0

R/W

Yes

RFID Offset of a tag

<RA>2,To:

ENCODING_ACTION

"0": Normal Action

"1": Feed Action

However, if "RFID_TAG_OFFSET" is 26 mm or more, it can not be changed to '1: Feed Action'.

The above specification is since 1.14.0. Prior to that, ["0": Normal Action] is fixed unconditionally.

0

R/W

Yes

Encoding Action

ANTENNA_POWER (WRITE)

[CL4NX/CL6NX UHF]

"0" to "240": Unit x0.1 dBm

[CL4NX/CL6NX plus UHF]

"0" to "300": Unit x0.1 dBm

(When the region is Japan)

"0" to "240": Unit x0.1 dBm

(When the region is Indonesia2)

"0" to "260": Unit x0.1 dBm

(When the region is Singapore / Vietnam / Philippines / Taiwan / Russian Federation)

"0" to "270": Unit x0.1 dBm

[CL4NX/CL6NX HF/ CL4NX/CL6NX plus HF]

"0" to "300": Unit x0.1 dBm

150
(x0.1 dBm)

R/W

Yes

Antenna output (WRITE)

<RA>2,Pw:

* The setting value in the HF band is not reflected.

Note: While a value from 0 to 300 can be recorded in the nonvolatile memory of the printer, the units place is rounded off to 0 during transmission to the reader/writer module.

Example: Even when 199 is specified, actually, 19.0 dBm is set.:

* Only when RFID is valid

UHF: It is necessary to restart after changing the settings on other than the setting screen.

ANTENNA_POWER (READ)

[CL4NX/CL6NX UHF]

"0" to "240": Unit x0.1 dBm

[CL4NX/CL6NX plus UHF]

"0" to "300": Unit x0.1 dBm

(When the region is Japan)

"0" to "240": Unit x0.1 dBm

(When the region is Indonesia2)

"0" to "260": Unit x0.1 dBm

(When the region is Singapore / Vietnam / Philippines / Taiwan / Russian Federation)

"0" to "270": Unit x0.1 dBm

[CL4NX/CL6NX HF/ CL4NX/CL6NX plus HF]

"0" to "300": Unit x0.1 dBm

150
(x0.1 dBm)

R/W

Yes

Antenna output (READ)

* The setting value in the HF band is not reflected.

Note: While a value from 0 to 300 can be recorded in the nonvolatile memory of the printer, the units place is rounded off to 0 during transmission to the reader/writer module.

Example: Even when 199 is specified, actually, 19.0 dBm is set.

* Only when RFID is valid

UHF: It is necessary to restart after changing the settings on other than the setting screen.

RFID_ERROR_OUTPUT

"0": PULSE

"1": LEVEL

1

R/W

Yes

RFID error output type

<RA>2,Pm:

LENGTH_OF_PULSE

"0": 100ms

"1": 200ms

"2": 300ms

"3": 400ms

"4": 500ms

0

R/W

Yes

RFID Error pulse time

<RA>2,Pl:

NON_RFID_WARNING

"0": Disable

"1": RFID Tag

"2": RFID Command

0

R/W

Yes

NON-RFID Warning

LOG_RFID_DATA

"0": Disable

"1": Enable

0

R/W

Yes

RFID data log record

DATA_TO_RECORD

[UHF]

(Ver prior to 1.15.5)

"0": BOTH

"1": EPC

"2": TID

(Ver 1.15.6 and above)

"0":EPC / TID

"1":EPC

"2":TID

"4":USER

"5":EPC / USER

"6":TID / USER

"7":EPC / TID / USER

"8":PC/AFI

"9":EPC / PC/AFI

"10":TID / PC/AFI

"11":EPC / TID / PC/AFI

"12":USER / PC/AFI

"13":EPC / USER / PC/AFI

"14":TID / USER / PC/AFI

"15":EPC / TID / USER / PC/AFI

[HF]

(Ver prior to 1.15.5)

"1":UID/IDm

(Ver 1.15.6 and above)

"1":UID

"2":USER

"3":UID / USER

UHF:0

HF:1

R/W

Yes

RFID record data type

USER_LOGGING_START
(Ver 1.15.6 and above)

[UHF]

"0"~"2047"

Input limit so that the sum of the Logging Start Address and Logging Size is less than or equal to 2048.

[HF]

"0"~"4095"

Input limit so that the sum of the Logging Start Address and Logging Size is less than or equal to 4096.

0

R/W

○

Logging Start Address

The unit is digits (4 bits).

Note that if an odd number is specified in the ASCII specification of DC2+PJ, the characters will appear to be corrupted.

When specifying an address in the HF band, multiply the byte value by two and set the value.

If an item containing USER is not set in the Data To Record, this item cannot be changed.

USER_LOGGING_SIZE
(Ver 1.15.6 and above)

[UHF]

"1"~"2048"

Input limit so that the sum of the Logging Start Address and Logging Size is less than or equal to 2048.

[HF]

"1"~"4096"

Input limit so that the sum of the Logging Start Address and Logging Size is less than or equal to 4096.

512

R/W

○

Logging Size

The unit is digits (4 bits).

Note that if an odd number is specified in the ASCII specification of DC2+PJ, the characters will appear to be corrupted.

When specifying an address in the HF band, multiply the byte value by two and set the value.

If an item containing USER is not set in the Data To Record, this item cannot be changed.

RSSI_FILTER

"0": Disable
"1": Enable

0

R/W

Yes

RSSI filtering feature

RSSI_FILTER_VAL

"-99" to "-1": unit dBm

-50

R/W

Yes

RSSI threshold

PAPER_TYPES

"0": Label
"1": Side Hole Tag

0

R/W

Yes

Media

STARTING_POINT

"-600" - "600": unit dot

0

R/W

Yes

Print Start Position

PLD_VERSION

"X.X" (X: 0 - F)

-

R

No

PLD Version on SRA board

SRA_LABEL_PITCH

(Ver.1.14.0 supported)

203 dpi: 8-1920 dots (1-240 mm)

305 dpi: 12-2880 dots (1-240 mm)

609 dpi: 24-5760 dots (1-240 mm)

203 dpi: 8

305 dpi: 12

609 dpi: 24

R/W

Yes

Pitch Size

CT4-LX/HC4-LX Series

Name of Setting item Setting value Default Value R/W Initial: IF Contents of Setting item

RFID_LIFE_COUNT_SUCCESS

"0" to "999999"

0

R

No

RFID success count of life

SOH+RB

RFID_LIFE_COUNT_FAILURE

"0" to "999999"

0

R

No

RFID failure count of life

SOH+RB

RFID_LIFE_COUNT_TOTAL

"0" to "999999"

0

R

No

RFID print count of life

SOH+RB

RFID_COUNT_SUCCESS

"0" to "999999"

0

R

Yes

RFID success count

SOH+RB

RFID_COUNT_FAILURE

"0" to "999999"

0

R

Yes

RFID failure count

SOH+RB

RFID_COUNT_TOTAL

"0" to "999999"

0

R

Yes

RFID print count

SOH+RB

CLEAR_RFID_COUNT

"0": Disable

"1": Enable

0

W

Yes

RFID counter clear

<RA>2,Rc:

READER_MODEL

"XXXXXXXXXXXXXXXX"

-

R

No

Model of reader

READER_VERSION

"XXXXXXXXXXXXXXXX"

-

R

No

Version of reader

RFID_PITCH

[UHF]

"0": Normal

"1": Front

[HF]

"0": Forward

"1": Center

"2": Backward

0

R/W

Yes

RFID antenna position

* Only when RFID is valid

Reboot is required after setting.

RFID_LABEL_DATA

"0": RETRY

"1": RELEASE

0

R/W

Yes

RFID Retry mode

<RA>2,Ed:

MAX_RETRY_LABEL

"0" to "9"

1

R/W

Yes

RFID Retry print

<RA>2,Ec:

MAX_RETRY_COUNT

"0" to "9"

4

R/W

Yes

RFID Retry count

<RA>2,Rt:

RFID_ERROR_SLASH

"0": Disable

"1": Enable

1

R/W

Yes

RFID Error slanted line printing

<RA>2,Es:

RFID_TAG_OFFSET

"-25" to "240" mm

"-25" to "25": Unit mm (When [Encoding Action] is "Feed Action". See below (*1) for detail).

(6.6.0 and later)

If label wasteless print setting (see [Printing]-[Advanced]-[Label Waste Prevention]) is selected, or if the current print mode (see [Printing]-[Print Mode]) is specified as other than "Continuous" the minimum value is set at 0 for the either case. (cf. "PRINT_AUTO" and "PRINT" [PRINTER] section)


(6.5.0)

If the current print mode (see [Printing]-[Print Mode]) is specified as other than "Continuous" the minimum value is set at 0 for the either case. (cf. "PRINT_AUTO" and "PRINT" [PRINTER] section)


(6.5.0 and older)

The minimum value is unconditionally set at 0.

  1. When the value specified in command is set to 26 mm to 240 mm, [Encoding Action] is forced to ["0": Normal Action] even if [Encoding Action] is ["1": Feed Action].

Constraints at minus tag offset:

If [Tag Offset]: RFID_TAG_OFFSET is set to -1mm or less when [Encoding Action]: ENCODING_ACTION is set to [Normal Action], [Pitch Size] must be specified accurately.

Please set the exact pitch size in [Pitch Size]: SRA_LABEL_PITCH.

0

R/W

Yes

RFID Offset of a tag

<RA>2,To:

ENCODING_ACTION

"0": Normal Action

"1": Feed Action

However, if "RFID_TAG_OFFSET" is 26 mm or more, it can not be changed to '1: Feed Action'.

The above is the specification of after 6.5.0. Prior to that, ["0": Normal Action] is fixed unconditionally.

0

R/W

Yes

Encoding Action

ANTENNA_POWER (WRITE)

"0" to "240": Unit x0.1 dBm (When the region is Japan)

"0" to "260": Unit x0.1 dBm (When the region is Indonesia)

"0" to "270": Unit x0.1 dBm

150
(x0.1 dbm)

R/W

Yes

Antenna output (WRITE)

<RA>2,Pw:

Note: While a value from 0 to 300 can be recorded in the nonvolatile memory of the printer, the units place is rounded off to 0 during transmission to the reader/writer module.

Example: Even when 199 is specified, actually, 19.0 dBm is set.

* Only when RFID is valid

UHF: It is necessary to restart after changing the settings on other than the setting screen.

ANTENNA_POWER (READ)

"0" to "240": Unit x0.1 dBm (When the region is Japan)

"0" to "260": Unit x0.1 dBm (When the region is Indonesia)

"0" to "270": Unit x0.1 dBm

150
(x0.1 dBm)

R/W

Yes

Antenna output (READ)

Note: While a value from 0 to 300 can be recorded in the nonvolatile memory of the printer, the units place is rounded off to 0 during transmission to the reader/writer module.

Example: Even when 199 is specified, actually, 19.0 dBm is set.

* Only when RFID is valid

UHF: It is necessary to restart after changing the settings on other than the setting screen.

NON_RFID_WARNING

"0": Disable

"1": RFID Tag

"2": RFID Command

0

R/W

Yes

RFID Undetected Warning

LOG_RFID_DATA

"0": Disable

"1": Enable

0

R/W

Yes

RFID data log record

DATA_TO_RECORD

[UHF]

(Ver prior to 6.7.1)

"0": BOTH

"1": EPC

"2": TID

(Ver 6.7.4 and above)

"0":EPC / TID

"1":EPC

"2":TID

"4":USER

"5":EPC / USER

"6":TID / USER

"7":EPC / TID / USER

"8":PC/AFI

"9":EPC / PC/AFI

"10":TID / PC/AFI

"11":EPC / TID / PC/AFI

"12":USER / PC/AFI

"13":EPC / USER / PC/AFI

"14":TID / USER / PC/AFI

"15":EPC / TID / USER / PC/AFI

[HF]

(Ver prior to 6.7.1)

"1":UID/IDm

(Ver 6.7.4 and above)

"1":UID

"2":USER

"3":UID / USER

UHF:0

HF:1

R/W

Yes

RFID record data type

UHF: If Compatibility RFID (COMPATIBLE_RFID) is enabled, only 0 to 2 can be set.

HF: If Compatibility RFID (COMPATIBLE_RFID) is enabled, only 1 can be set.

USER_LOGGING_START
(Ver 6.7.4 and above)

[UHF]

"0"~"2047"

Input limit so that the sum of the Logging Start Address and Logging Size is less than or equal to 2048.

[HF]

"0"~"4095"

Input limit so that the sum of the Logging Start Address and Logging Size is less than or equal to 4096.

0

R/W

Yes

Logging Start Address

The unit is digits (4 bits).

Note that if an odd number is specified in the ASCII specification of DC2+PJ, the characters will appear to be corrupted.

When specifying an address in the HF band, multiply the byte value by two and set the value.

If an item containing USER is not set in the Data To Record, this item cannot be changed.

USER_LOGGING_SIZE
(Ver 6.7.4 and above)

[UHF]

"1"~"2048"

Input limit so that the sum of the Logging Start Address and Logging Size is less than or equal to 2048.

[HF]

"1"~"4096"

Input limit so that the sum of the Logging Start Address and Logging Size is less than or equal to 4096.

512

R/W

Yes

Logging Size

The unit is digits (4 bits).

Note that if an odd number is specified in the ASCII specification of DC2+PJ, the characters will appear to be corrupted.

When specifying an address in the HF band, multiply the byte value by two and set the value.

If an item containing USER is not set in the Data To Record, this item cannot be changed.

RSSI_FILTER

"0": Disable
"1": Enable

0

R/W

Yes

RSSI filtering feature

RSSI_FILTER_VAL

"-99" to "-1": unit dBm

-50

R/W

Yes

RSSI threshold

STARTING_POINT

"-200" to "200": unit dot

0

R/W

Yes

Print Start Position

COMPATIBLE_RFID

"0": Disable

"1": Enable

0

R/W

Yes

Compatibility RFID

SRA_LABEL_PITCH

(Ver.6.5.0 supported)

203 dpi: 8 to 1920 dots (1-240 mm)

305 dpi: 12 to 2880 dots (1-240 mm)

203 dpi: 8

305 dpi: 12

R/W

Yes

Pitch Size

S84NX/S86NX

Name of Setting item Setting value Default Value R/W Initial: IF Contents of Setting item

RFID_LIFE_COUNT_SUCCESS

"0" to "999999"

0

R

No

RFID success count of life

SOH+RB

RFID_LIFE_COUNT_FAILURE

"0" to "999999"

0

R

No

RFID failure count of life

SOH+RB

RFID_LIFE_COUNT_TOTAL

"0" to "999999"

0

R

No

RFID print count of life

SOH+RB

RFID_COUNT_SUCCESS

"0" to "999999"

0

R

Yes

RFID success count

SOH+RB

RFID_COUNT_FAILURE

"0" to "999999"

0

R

Yes

RFID failure count

SOH+RB

RFID_COUNT_TOTAL

"0" to "999999"

0

R

Yes

RFID print count

SOH+RB

CLEAR_RFID_COUNT

"0": Disable

"1": Enable

0

W

Yes

RFID counter clear

<RA>2,Rc:

READER_MODEL

"XXXXXXXXXXXXXXXX"

-

R

No

Model of reader

READER_VERSION

"XXXXXXXXXXXXXXXX"

-

R

No

Version of reader

RFID_PITCH

[S84NX]

"0": Normal

"1": Front

[S86NX]

"0": Normal

0

R/W

Yes

RFID antenna pitch

* Only when RFID is valid

It is necessary to restart after changing the settings on other than the setting screen.

RFID_LABEL_DATA

"0": RETRY

"1": RELEASE

0

R/W

Yes

RFID Retry mode

<RA>2,Ed:

MAX_RETRY_LABEL

"0" to "9"

1

R/W

Yes

RFID Retry print

<RA>2,Ec:

MAX_RETRY_COUNT

"0" to "9"

4

R/W

Yes

RFID Retry count

<RA>2,Rt:

RFID_ERROR_SLASH

"0": Disable

"1": Enable

1

R/W

Yes

RFID Error slanted line printing

<RA>2,Es:

RFID_ERROR_SLASH_MODE

"0": Variable

"1": Fixed

0

R/W

Yes

RFID Error slanted line printing with ignoring label size.

(Ver 8.2.0)

RFID_TAG_OFFSET

"-15" to "240" mm

"-15" to "15" mm (When [Encoding Action] is "Feed Action". See below (*1) for detail.)

If the current print operation mode (refer to [Printing]-[Print Mode]) is not "Continuous", the minimum value is 0.
cf.[PRINTER] section PRINT_AUTO and PRINT

  1. When the value specified in command is set to 16 mm to 240 mm, [Encoding Action] is forced to ["0": Normal Action] even if "Encoding Action" is ["1": Feed Action].

Constraints at minus tag offset:

If [Tag Offset]: RFID_TAG_OFFSET is set to -1mm or less when [Encoding Action] ]: ENCODING_ACTION is set to [Normal Action], [Pitch Size] must be specified accurately.

Please set the exact pitch size in [Pitch Size].

0

R/W

Yes

RFID Offset of a tag

<RA>2,To:

ANTENNA_POWER (WRITE)

"0" to "300": Unit x0.1 dBm

(When the region is Japan)

"0" to "240": Unit x0.1 dBm

(When the region is Indonesia)

"0" to "260": Unit x0.1 dBm

(When the region is Singapore / Vietnam / Philippines / Taiwan / Russian Federation)

"0" to "270": Unit x0.1 dBm

100
(x0.1 dBm)

R/W

Yes

Antenna output (WRITE)

<RA>2,Pw:

Note: While a value from 0 to 300 can be recorded in the nonvolatile memory of the printer, the units place is rounded off to 0 during transmission to the reader/writer module.

Example: Even when 199 is specified, actually, 19.0 dBm is set.:

ANTENNA_POWER (READ)

"0" to "300": Unit x0.1 dBm

(When the region is Japan)

"0" to "240": Unit x0.1 dBm

(When the region is Indonesia)

"0" to "260": Unit x0.1 dBm

(When the region is Singapore / Vietnam / Philippines / Taiwan / Russian Federation)

"0" to "270": Unit x0.1 dBm

100
(x0.1 dBm)

R/W

Yes

Antenna output (READ)

Note: While a value from 0 to 300 can be recorded in the nonvolatile memory of the printer, the units place is rounded off to 0 during transmission to the reader/writer module.

Example: Even when 199 is specified, actually, 19.0 dBm is set.:

RFID_ERROR_OUTPUT

"0": PULSE

"1": LEVEL

1

R/W

Yes

RFID error output type

<RA>2,Pm:

LENGTH_OF_PULSE

"0": 100ms

"1": 200ms

"2": 300ms

"3": 400ms

"4": 500ms

0

R/W

Yes

RFID Error pulse time

<RA>2,Pl:

NON_RFID_WARNING

"0": Disable

"1": RFID Tag

"2": RFID Command

0

R/W

Yes

NON-RFID Warning

LOG_RFID_DATA

"0": Disable

"1": Enable

0

R/W

Yes

RFID data log record

DATA_TO_RECORD

(Ver prior to 8.2.0)

"0": BOTH

"1": EPC

"2": TID

(Ver 8.2.1 and above)

"0":EPC / TID

"1":EPC

"2":TID

"4":USER

"5":EPC / USER

"6":TID / USER

"7":EPC / TID / USER

"8":PC/AFI

"9":EPC / PC/AFI

"10":TID / PC/AFI

"11":EPC / TID / PC/AFI

"12":USER / PC/AFI

"13":EPC / USER / PC/AFI

"14":TID / USER / PC/AFI

"15":EPC / TID / USER / PC/AFI

0

R/W

Yes

RFID record data type

USER_LOGGING_START
(Ver 8.2.1 and above)

"0"~"2047"

Input limit so that the sum of the Logging Start Address and Logging Size is less than or equal to 2048.

0

R/W

○

Logging Start Address

The unit is digits (4 bits).

Note that if an odd number is specified in the ASCII specification of DC2+PJ, the characters will appear to be corrupted.

If an item containing USER is not set in the Data To Record, this item cannot be changed.

USER_LOGGING_SIZE
(Ver 8.2.1 and above)

"1"~"2048"

Input limit so that the sum of the Logging Start Address and Logging Size is less than or equal to 2048.

512

R/W

○

Logging Size

The unit is digits (4 bits).

Note that if an odd number is specified in the ASCII specification of DC2+PJ, the characters will appear to be corrupted.

If an item containing USER is not set in the Data To Record, this item cannot be changed.

RSSI_FILTER

"0": Disable
"1": Enable

0

R/W

Yes

RSSI filtering feature

RSSI_FILTER_VAL

"-99" to "-1": unit dBm

-50

R/W

Yes

RSSI threshold

PAPER_TYPES

"0": Label
"1": Side Hole Tag

0

R/W

Yes

Media

STARTING_POINT

"-600" - "600": unit dot

0

R/W

Yes

Print Start Position

ENCODING_ACTION

"0": Normal Action

"1": Feed Action

However, if "RFID_TAG_OFFSET" is 16 mm or more, it can not be changed to '1: Feed Action'.

The above specification is the specification of 8.2.0. ["0": Normal Action] is fixed unconditionally.

0

R/W

Yes

Encoding Action

SRA_LABEL_PITCH

(Ver.8.2.0 supported)

203 dpi: 8-1920 dots (1-240 mm)

305 dpi: 12-2880 dots (1-240 mm)

609 dpi: 24-5760 dots (1-240 mm)

203 dpi: 8

305 dpi: 12

609 dpi: 24

R/W

Yes

Pitch Size

FAST_RFID_ENCODING

"0": Disable

"1": Enable

0

R/W

Yes

Fast RFID Encoding

RFID_ERROR_DISPLAY

"0": Disable

"1": Enable

1

R/W

Yes

Error display