External Signal Interface [CL4NX/CL6NX]

Basic Specifications

External signal interface is designed to connect the printer to external peripheral devices.

External signal interface works only in pulse input mode (print by external signal input). Error signal is output in any mode if an error occurs in the printer.

External signal setting is set in the [Interface] > [External I/O] of the printer.

Connector

Amphenol 14 pin receptacle (female)


For connector, use DDK's 57 series 14-pin (57-30130 etc.) or the like.

I/O Circuit Diagram

Signal Level

High +4.2 - 5 V: Input terminal: Iin≒0 mA, Output terminal: Iout≒0 mA

Low 0 - 0.7 V or less: Input terminal Iin≒10 mA, Output terminal Iout≒50 mA

Print by External Signal

Set "ENABLE/DISABLE" in the [Interface] > [External I/O].

External Signal Type

Following signal types are available in the [Interface] > [External I/O] > [Signals] > [EXT Mode].

Type Operation
TYPE 1 Print end signal (PREND) is "High" before printing labels. The signal level is "Low" after the completion of print. The signal level will be "High" 20 ms later.
TYPE 2 Print end signal (PREND) is "Low" before printing labels. The signal level is "High" after the completion of print. The signal level will be "Low" 20 ms later.
TYPE 3 Print end signal (PREND) is "High" before printing labels. The signal level is "Low" from the start to the end of print and will be "High" after the completion of print.
TYPE 4 Print end signal (PREND) is "Low" before printing labels. The signal level is "High" from the start to the end of print and will be "Low" after the completion of print.

Reissuing EXT Signal

Set "Enable/Disable" in the [Interface] > [External I/O].

Enable: Reprint the same content

Disable: No reprint

Dispenser Completion Signal

Sets pin number for dispenser completion signal in [Interface] > [External I/O] > [Signals] > [Outputs] settings.

When pin no. is set: Outputs dispenser completion signal when dispenser motion is completed. (Sets signal level to Low)

When set, it works with the sequence of dispenser completion signal.

When pin number is not set: Dispenser completion signal state won't change while waiting for dispenser motion to complete.

Label Near End

Sets pin number for dispenser completion signal in [Interface] > [External I/O] > [Signals] > [Outputs] settings.

When pin No. is set: Outputs label near end when detected label near end. (Sets signal level to Low)

When pin number is not set: Label near end state will not change while for label near end.

Connector Pin Assignment

Standard Specifications

Pin no.
(14 pin)
Signal name Contents Input / Output Level Electric condition
(voltage, current (MAX))
1 Paper end signal Output when paper end is detected. Open collector output Low Pressure proof 50 V
Sink current 50 mA
2 GND SIGNAL GROUND - - -
3 Ribbon end signal Output when detect ribbon end. Open collector output Low Pressure proof 50 V
Sink current 50 mA
4 Machine error signal Output when Head open, Head error or communication error occurs. Open collector output Low Pressure proof 50 V
Sink current 50 mA
5

Print start signal

(PRIN)

Print one label every time when this signal is input. Input Low High: Hi-impedance
Low: -15 mA<, 0 V
6

Print end signal

(PREND)*1, *2

Output when the printer prints one label. Open collector output Low Pressure proof 50 V
Sink current 50 mA
7

Re-print signal

(PRIN2)

Print the same content again by input this signal. Input Low High: Hi-impedance
Low: -15 mA<, 0 V
8 EXT5V_IN*3 For external power supply Input - 5 V
9

Print ready signal

(MODE1)

Outputs a high signal when there is print data in the printer in Online mode. Otherwise, outputs a low signal.

Open collector output ― Pressure proof 50 V
Sink current 50 mA

Online/Offline signal*4

(MODE2)

Outputs a high signal when the printer is in Online mode.

Outputs a low signal when the printer is in Offline mode.

10 Ribbon near end signal Output when detecting ribbon is near end. Open collector output High Pressure proof 50 V
Sink current 50 mA
11 - - - - -
12 +24 V - - - 2 A
13 +5 V - - - 500 mA
14 - - - - -
- Waiting for Dispenser completion signal*5, *6 Outputs signal while waiting for dispenser completion signal. Open collector output Low Pressure proof 50 V
Sink current 50 mA
- Label near end signal*5 Output when detect label near end. Open collector output High Pressure proof 50 V
Sink current 50 mA

RFID Specifications

Pin no.
(14 pin)
Signal name Contents Input / Output Level Electric condition
(voltage, current (MAX))
1 Paper end + Ribbon end signal

Output when paper end or ribbon end is detected.

Open collector output Low Pressure proof 50 V
Sink current 50 mA
2 GND SIGNAL GROUND - - -
3 RFID tag error signal Output when RFID tag error occurs. Open collector output Low Pressure proof 50 V
Sink current 50 mA
4 Machine error / RFID error signal

Output when head open, head error, communication error, or other error occurs. /

Output when RFID system error occurs.

Open collector output Low Pressure proof 50 V
Sink current 50 mA
5

Print start signal

(PRIN)

Print one label every time when this signal is input. Input Low High: Hi-impedance
Low: -15 mA<, 0 V
6

Print end signal

(PREND)*1, *2

Output when the printer prints one label. Open collector output Low Pressure proof 50 V
Sink current 50 mA
7

Re-print signal

(PRIN2)

Print the same content again by input this signal. Input Low High: Hi-impedance
Low: -15 mA<, 0 V
8 EXT5V_IN*3 For external power supply Input - 5 V
9

Print ready signal

(MODE1)

Outputs a high signal when there is print data in the printer in Online mode.

Otherwise, outputs a low signal.

Open collector output - Pressure proof 50 V
Sink current 50 mA

Online/Offline signal*4

(MODE2)

Outputs a high signal when the printer is in Online mode. Outputs a low signal when the printer is in Offline mode.

10 Ribbon near end signal Output when detecting ribbon is near end. Open collector output High Pressure proof 50 V
Sink current 50 mA
11 - - - - -
12 +24 V - - - 2 A
13 +5 V - - - 500 mA
14 - - - - -
- Waiting for Dispenser completion signal*5, *6 Outputs signal while waiting for dispenser completion signal. Open collector output Low Pressure proof 50 V
Sink current 50 mA
- Label near end signal*5 Output when detect label near end. Open collector output High Pressure proof 50 V
Sink current 50 mA
  1. Select TYPE1 to TYPE4 for No.6 pin "PREND" output signal. For details, refer to external signal type in Basic Specification.
  2. No. 6 pin "PREND" output signal is not output when "0" is specified as number of cuts for cut unit number command in cutter operation.
  3. When SW14 on IF board is set to 2-3, the printer operates by power supply from EXT5V_IN (No. 8 pin). When set to 1-2 side, the printer operates by internal power supply (Set to 1-2 side as shipment settings).
  4. When SW15 on IF board is set to 2-3, the no.9 pin operates as offline output. When set to 1-2 side, the printer operates as input (Set to 2-3 as shipment settings).
  5. Output pin No. can be set for Waiting for dispenser completion and label near end from Exit Signals from settings on GUI. Initial value: "Unspecified."
  6. Output timing of print end signal (PREND) is changed when Wait signal for dispenser is set to valid. Refer to "Output waiting for dispenser" in Explanation of Output Signal for details.

Important

  • External signal may become unstable for around 1 second after power on. Please control after 1 second.
  • Signal level changes when the conditions in the "Contents" column are met.

    e.g. 1) For Pin no.1, signal level becomes Low when Paper End occurs. Then the switch is turned on and the current flows.

    e.g. 2) The print start signal for pin no.5 is when the signal is set to Low level and current flows.

Note

  • The mapping of pin no. and signal name (contents) can be changed via Interface > External I/O menu.

Explanation of Input Signal

Print Start Signal (PRIN)

Reprint Signal (PRIN2)

Without print start signal

With reprint signal

Note

  • Keep "Low" for print start signal (PRIN) until print end signal (PREND) is output.

    For details, refer to "Keeping print start signal (PRIN)" below.

    Make sure to output 10 ms or more for reprint signal (PRIN2).

    Printer will not reprint if reprint signal cannot be detected from 10 ms and under.

  • If NULL cut specified not output print end signal (PREND).

Keeping print start signal (PRIN)

Keep "Low" for print start signal (PRIN) until print end signal (PREND) is output.

When PREND signal is TYPE 1 or 2

When PREND signal is TYPE 3 or 4

PREND signal timing chart

  • The startup and shutdown of PREND signal takes 150 ms or less. Connected devices shall emit PRIN signal considering this time.
  • When print start signal and reprint signal is emitted at the same time, print start signal is enabled and reprints.
  • Reprint signal will be enabled from the end of printing (QTY=0) until receiving print data. The printer will not reprint other than that time.

Explanation of Output Signal

Print End Signal (PREND)

Paper End Signal

Ribbon End Signal

Machine Error Signal

Ribbon Near End / Label Near End Signal

Online / Offline Signal

Waiting for Dispenser Signal

Operation 1 (backfeed after printing)

Operation 2 (backfeed before printing)

Note

  • Please note that Output timing of print end signal (PREND) is changed when Wait signal for dispenser is valid.

    Operation 1) Output Print End Signal after Wait label for dispenser is removed and backfeeding of label is completed to print start position.

    Operation 2) Output Print End Signal after feeding label to dispense position.

RFID Error and Reset Timing

Turns on the signal when an RFID system error occurs, and when the RFID tag error occurs (when reprint count reaches the specified number). The signal will be turned OFF if the error is canceled.

Error Signal Output by One-shot Pulse

Turns on the signal when a read / write error occurs. The signal will be turned OFF automatically after 100 to 500 ms. RFID error signal turns ON when the number of RFID reprints reaches the specified number. RFID error signal is always output at the level. However, if the RFID reprint count is set to "0", RFID error signal does not change.


  1. This is the operation when the minus tag offset is set. In other cases, this section will not operate.
Error Signal Output by Level Output

Turns on the signal when a read / write error occurs. The signal will be turned OFF if the error is canceled. RFID error signal turns ON when the number of RFID reprints reaches the specified number. RFID error signal is always output at the level. However, if the RFID reprint count is set to "0", RFID error signal does not change.


  1. This is the operation when the minus tag offset is set. In other cases, this section will not operate.
  2. Continues until after the error printing operation is completed.

Print Mode

The input of external signal works under the conditions where colored in blue.