External Signal Interface [S84NX/S86NX]

Basic Specifications

External signal interface is designed to connect the printer to external peripheral devices.

External signal interface works only in pulse input mode (print by external signal input).

External signal setting is set in the [Interface] > [External I/O] of the printer.

Connector

D-SUB 25 pin (female)

Amphenol 14 pin receptacle (female)

When using 14 pins external signal interface, please use the attached conversion cable (option).

I/O Circuit Diagram

D-SUB 25 pin (female)
  • When the output from the user is NPN transistor output

    [Power is supplied from the user]

    [Power is supplied from the printer]

  • When the output from the user is PNP transistor output

  • Amphenol 14 pin receptacle (female)

Signal Level

  • Input (NPN / PNP connection shared)

    Input connector ON: Iin = approx. 0 mA (high impedance)

    Input connector OFF: Iin = approx. 2 to 20 mA (0 to 0.7 V)

  • Output

    Output connector ON: Iout = approx. 80 mA

    Output connector OFF: Iout = approx. 0 mA

Print by External Signal

Following settings can be selected at [Interface] > [External I/O] > [Print Start Signal].

  • Enable: enable/disable print start signal
  • PIN: selectable external signal pin (AEP: printing starts when a request is sent from AEP app)
  • Signal State: enabled signal status

Reissuing EXT Signal

Following settings can be selected at [Interface] > [External I/O] > [EXT I/O Re-print].

  • Enable: enable/disable reprint via external signal
  • PIN: selectable external signal pin
  • Signal State: enabled signal status
  • Continuous Print: when enabled, reprint can be executed via print start signal. Reprint can be executed either by enabling this setting or by the PIN assigned to a reprint signal.
  • Enhanced Reprint: reprints the data just printed even when the print data remains (QTY≠0).

Connector Pin Assignment

Standard Specifications

25 pins 14 pins Signal name Contents Input / Output Level*3 Electric condition
(voltage, current (MAX))
1 14 FG Frame ground - - -
2 - +5 V Power source - - +5 V
600 mA*4
3 -

Home position signal

Signal is output at backfeed motion control and backfeed is already done. Output Low 400 V
80 mA
4 4 Machine error signal Output with cover open, head error, communication error and so on. Output Low 400 V
80 mA
5 6

Print done signal

(PREND)

Signal is output at the operation of the printer issues one label. Output Low 400 V
80 mA
6 9 Print ready signal Signal will be ON if the print data is available online. Output High 400 V
80 mA
7 - Label near end signal By input of this signal, the printer becomes label near end status. Input*2 Low High: high impedance
Low: more than -5 mA, 0 V
8 7

Reprint signal

(PRIN2)

By input of this signal, the printer reprints the same contents for one time. Input*2 Low High: high impedance
Low: more than -5 mA, 0 V
9 -

Backfeed order signal

(DISPENSE IN)

By input of this signal, backfeed is done at backfeed motion control. Input*2 Low High: high impedance
Low: more than -5 mA, 0 V
10 - Reserve Reserve Input*2 - High: high impedance
Low: more than -5 mA, 0 V
11 - OUT_COM Ground of peripherals - - -
12 13 +5 V Power source - - +5 V
600 mA*4
13 12 +24 V Power source - - +24 V
2 A
14 2 GND Signal ground - - -
15 2 OUT_COM Ground of peripherals - - -
16 3 Ribbon end signal Output at ribbon end detection Output Low 400 V
80 mA
17 1 Paper end signal Output at paper end detection Output Low 400 V
80 mA
18 10 Ribbon near end signal Output at ribbon near end detection Output High 400 V
80 mA
19 - Reserve Reserve Output - 400 V
80 mA
20 5

Print start signal

(PRIN)

The printer issues one label by input of this signal. Input*2 Low High: high impedance
Low: more than -5 mA, 0 V
21 11 Feed signal The printer feeds by input of this signal. Input*2 Low High: high impedance
Low: more than -5 mA, 0 V
22 - Reserve Reserve Input*2 - High: high impedance
Low: more than -5 mA, 0 V
23 - Reserve Reserve Input*2 - High: high impedance
Low: more than -5 mA, 0 V
24 13 IN_COM*1 For power supply from peripherals. Input - 5 V - 24 V or GND
25 - GND Signal ground - - -

RFID Specifications

25 pins 14 pins Signal name Contents Input / Output Level*3 Electric condition
(voltage, current (MAX))
1 14 FG Frame ground - - -
2 - +5 V Power source - - +5 V
600 mA*4
3 -

Home position signal

Signal is output at backfeed motion control and backfeed is already done. Output Low 400 V
80 mA
4 4 Machine error / RFID error signal*5

Output with cover open, head error, communication error and so on. / Output with RFID system error.

Output Low 400 V
80 mA
5 6

Print done signal

(PREND)

Signal is output at the operation of the printer issues one label. Output Low 400 V
80 mA
6 9 Print ready signal Signal will be ON if the print data is available online. Output High 400 V
80 mA
7 - Label near end signal By input of this signal, the printer becomes label near end status. Input*2 Low High: high impedance
Low: more than -5 mA, 0 V
8 7

Reprint signal

(PRIN2)

By input of this signal, the printer reprints the same contents for one time. Input*2 Low High: high impedance
Low: more than -5 mA, 0 V
9 -

Backfeed order signal

(DISPENSE IN)

By input of this signal, backfeed is done at backfeed motion control. Input*2 Low High: high impedance
Low: more than -5 mA, 0 V
10 - Reserve Reserve Input*2 - High: high impedance
Low: more than -5 mA, 0 V
11 - OUT_COM Ground of peripherals - - -
12 13 +5 V Power source - - +5 V
600 mA*4
13 12 +24 V Power source - - +24 V
2 A
14 2 GND Signal ground - - -
15 2 OUT_COM Ground of peripherals - - -
16 3 RFID tag error signal*5 Output when RFID tag error occurs Output Low 400 V
80 mA
17 1 Paper end signal / Ribbon end signal*5

Output at paper end detection

Output at ribbon end detection

Output Low 400 V
80 mA
18 10 Ribbon near end signal Output at ribbon near end detection Output High 400 V
80 mA
19 - Reserve Reserve Output - 400 V
80 mA
20 5

Print start signal

(PRIN)

The printer issues one label by input of this signal. Input*2 Low High: high impedance
Low: more than -5 mA, 0 V
21 11 Feed signal The printer feeds by input of this signal. Input*2 Low High: high impedance
Low: more than -5 mA, 0 V
22 - Reserve Reserve Input*2 - High: high impedance
Low: more than -5 mA, 0 V
23 - Reserve Reserve Input*2 - High: high impedance
Low: more than -5 mA, 0 V
24 13 IN_COM*1 For power supply from peripherals. Input - 5 V - 24 V or GND
25 - GND Signal ground - - -
  1. When using the 14 pins external signal interface, do not connect the power pin to "IN_COM" pin. The "IN COM" pin is connected to "5 V" in cable.
  2. It can be connected to equipment of open collector input to the signal input terminal.
  3. Output of the pin without specified signal will be set at high.
  4. If 25 pin is selected, the total output of 2 pin and 12 pin will be 600 mA. Output voltage changes depending on the load level.
    Load level Output voltage
    No load Approx. 5.25 V
    Load: 0.3 A Approx. 5.00 V
    Load: 0.6 A Approx. 4.75 V

    The voltage is 5.25 V or higher when there is no load. When a load is applied, the rated voltage will be reached.

  5. RFID models have different settings from the "Standard Specifications" table of the standard model.

Note

  • The mapping of pin no. and signal name (contents) can be changed via Interface > External I/O menu.

Explanation of Input Signal

Print Start Signal

If print start signal is turned ON when print data is available online, print will start.


Active low (default)


Active high


Negative pulse


Positive pulse


Note

  • In case of the falling edge or the rising edge, the signal will not be enabled unless the level is returned to high or low once. The signal output must be kept for 10ms or longer. If print start signal cannot be recognized when the signal output is not kept for 10ms or longer, print will not operate.
  • If [Interface]> [External I/O] > [EXT I/O Re-print] > [Continuous Print] is enabled, print data just before the current one will be set as a reprint data if print start signal is turned ON when print data is not available (QTY=0) online. After that, print will start by turning the print start signal ON.
  • If [Print Start Signal] > [Feed] is enabled and the print start signal is turned ON, when no print data or offline, feed will be executed.

    In that case, [EXT I/O Re-print] > [Continuous Print] will be disabled. In addition, even if feed signal is input, it will be ignored.

Reprint Signal

Print data just before the current one will be reprinted if the signal is turned ON when the print data is not available online.

To reprint the print data just before the current one when the print data is available (QTY≠0) online, [Interface]> [External I/O] > [EXT I/O Re-print] > [Enhanced Reprint] needs to be enabled.


Active low (default)


Active high


Negative pulse


Positive pulse


Note

  • Output the reprint signal for 10ms and longer. If reprint signal cannot be recognized when the signal output is not kept for 10 ms or longer, reprint will not operate.
  • If Enhanced Reprint is disabled, reprint signal will be enabled between print end (QTY=0) and print data receive, but reprint will not start in other conditions.
  • In case of Enhanced Reprint, enabled signal state for reprint signal will be the falling edge or Positive-pulse. In case of low active, it works in the falling edge, and in case of high active, it works in the rising edge.
  • If [Print Start Signal] > [Feed] is enabled, [EXT I/O Re-print] > [Continuous Print] will be disabled.

Label Near End Signal

If label near end signal is turned ON, label near end alert will be displayed in the status response and LCD screen.


Active low (default)

Active high

Feed Signal

Feed will be executed by turning the feed signal ON at the online, offline state.

The feed signal will be ignored when an error occurs.


Active low (default)


Active high


Falling edge


Rising edge


Low pulse


High pulse

Note

  • Output the feed signal for 100ms and longer. If the feed signal cannot be recognized when the signal output is not kept for 10ms or longer, feed will not operate.
  • If the sensor is enabled, one label will be feeded. The operation is repeated while the signal is ON.
  • If the sensor is disabled, print will not operate.
  • If [Print Start Signal] > [Feed] is enabled, feed signal will be ignored.

    Print start signal will perform the equivalent operation to that of feed signal.

  • When [Print Start Signal] > [Feed] is disabled and Low / High Pulse setting, the signal setting is set to Low Active (default).

Cancel Signal

Cancels print data by turning the cancel signal ON.


Negative pulse (default)

Positive pulse

Note

  • Output the cancel signal for 100 ms and longer. If the cancel signal cannot be recognized when the signal output is not kept for 10 ms or longer, cancel will not operate.
  • Cancel signal will be enabled under following conditions:
    • Print start signal (PRIN) stand-by state
    • Offline state
    • When an error occurs

Important

  • Do not cancel the print data while receiving the data. If the print data is canceled while receiving it, the operation cannot be guaranteed.

Online/Offline Signal

Switches online/offline by turning on online/offline signal.


Negative pulse (default)

Positive pulse

Note

  • Output the online/offline signal for 100 ms and longer. If the online/offline signal cannot be recognized when the signal output is not kept for 10 ms or longer, online/offline switch will not operate.
  • Only when online/offline switch can be executed using the key operation, online/offline switch can operate by online/offline signal.

Backfeed Order Signal

Starts backfeed by turning the backfeed order signal ON when backfeed operation is possible.


Negative pulse (default)

Positive pulse

Note

  • Backfeed order signal shall be held until print start position signal is output and backfeed order signal shall be disabled before print start signal input.
  • Operation of this signal is enabled under the following settings:
    • Operation mode: Dispenser (peeling)
    • Backfeed operation: Controled
  • If [Print Start Signal] > [Feed] is enabled, print start signal works as feed signal.

    Backfeed mode: even when the backfeed mode is set at [Controled], if print start signal (feed signal) is input, backfeed mode starts after the label is fed without waiting for the input of "Backfeed order signal".

Explanation of Output Signal

When setting the output signals for RFID, "RFID error" and "RFID tag error", set the following output signals by operating [Interface] > [External I/O].

  • Paper End/Ribbon End (Same as standard specifications)
  • Machine Error/RFID Error
  • RFID Error
  • RFID Tag Error

Print Done Signal

TYPE 1

Print done signal (PREND) is set at high before printing a label, and low after the print is complete. The signal level moves to high after 20 ms.

TYPE 2

Print done signal (PREND) is set at low before printing a label, and high after the print is complete. The signal level moves to low after 20 ms.

TYPE 3

Print done signal (PREND) is set at high before printing a label, and low from print start until the print is complete. The signal level moves to high after the print is complete.

TYPE 4 (default)

Print done signal (PREND) is set at low before printing label, and high from print start until the print is complete. The signal level moves to low after the print is complete.

Print End Signal

Turns the signal ON when paper end occurs. The signal will be turned OFF at the Offline (clear the error) state after the head opened.


Active low (default)


Active high

Ribbon End Signal

Turns the signal ON when ribbon end occurs. The signal will be turned OFF at the Offline (clear the error) state after the head opened.


Active low (default)


Active high

Machine Error Signal

Turns on the signal when an error occurs. The signal will be turned OFF if the error is canceled.


Active low (default)


Active high

Ribbon Near End Signal

Turns the signal ON when ribbon near end signal occurs. The signal will be turned OFF when print starts after ribbon near end signal is canceled or when feed starts.


Active low


Active high (default)

Online Signal

Turns the signal output ON at the online state. The signal will be turned OFF at the offline state, and when an error occurs.


Active low


Active high (default)

Print Ready Signal

Turns the signal ON when print data is available online.


Active low


Active high (default)

Data Present Signal

Turns the signal ON when print data is available.


Active low


Active high (default)

Home Position Signal

Turns the signal ON when a label is placed at the head position.


Active low (default)


Active high


Note

  • Operation of this signal is enabled under the following settings:
    • Operation mode: Dispenser (peeling)
    • Backfeed operation: Controled

Paper End/Ribbon End Signal

Turns the signal ON when paper end/ribbon end occurs. The signal will be turned OFF at the Offline (clear the error) state after the head opened.


Active low (default)


Active high

RFID Tag Error Signal

Error Signal Output by One-shot Pulse

Turns on the signal when a read/write error occurs. The signal will be turned OFF automatically after 100 to 500 ms.

Active low (default)

Active high


When reprint count reaches the specified number, RFID tag error and RFID error are output at the same time. RFID error is always output by long pulse.

The status shown in the signal diagram above is the number of re-prints not reached.

  1. This is the operation when the minus tag offset is set. In other cases, this section will not operate.

Error Signal Output by Level Output

Turns on the signal when a read/write error occurs. The signal will be turned OFF if the error is canceled.

Active low (default)

Active high

When reprint count reaches the specified number, RFID tag error and RFID error are output at the same time. RFID error is always output by long pulse.

The status shown in the signal diagram above is the number of re-prints not reached.

  1. This is the operation when the minus tag offset is set. In other cases, this section will not operate.
  2. It will continue until about 3 seconds have passed and error printing is completed.

    If [Error Display] is enabled, the error continues until printing is complete.

RFID Error Signal

Turns on the signal when an RFID system error occurs, and when the RFID tag error occurs (when reprint count reaches the specified number). The signal will be turned OFF if the error is canceled.


Active low (default)

* RFID tag error signal is output by 1-shot pulse output with low active setting.


Active high

* RFID tag error signal is output by 1-shot pulse output with low active setting.

Machine Error/RFID Error Signal

It controls both the machine error signal and the RFID error signal.

The machine error signal turns on when an error occurs. The signal will be turned OFF if the error is canceled. For the chart of the signal, refer to "Machine Error Signal" described above.

The RFID error signal turns on the signal when an RFID system error occurs, and when the RFID tag error occurs (when reprint count reaches the specified number). The signal will be turned OFF if the error is canceled. For the chart of the signal, refer to "RFID Error Signal" described above.

BCR Error Signal

Turns the signal ON when barcode reading / comparison error occurs. The signal will be turned OFF after the Offline (clear the error) state.


Active low (default)


Active high

Print Mode

The input of external signal works under the conditions where colored in blue.

Compatibility

The table below shows the enable/disable of the external signal function when the print start signal is disabled on S84NX/S86NX and the external signal is disabled on S84-ex/S86-ex.

Yes: Configurable and input/output is enabled

No: Cannot be configured or input/output is disabled

Input / Output Function name S84NX/S86NX S84-ex/S86-ex Note
Input Print Start Signal No No
Reprint Signal No No
Label Near End Signal Yes No
Feed Signal Yes Yes
Cancel Signal Yes Yes
Online/Offline Signal Yes Yes
Backfeed Order Signal No No
Output Print Done Signal No No
Paper End Signal Yes No
Ribbon End Signal Yes No
Machine Error Signal Yes No
Ribbon Near End Signal Yes No
Online Signal Yes No For S84-ex/S86-ex, when EXT 9PIN SELECT is set to MODE2/MODE3
Print Ready Signal Yes No For S84-ex/S86-ex, when EXT 9PIN SELECT is set to MODE1 or MODE3 and PRN READY TYPE is set to DATA READY
Data Present Signal Yes No For S84-ex/S86-ex, when EXT 9PIN SELECT is set to MODE3 and PRN READY TYPE is set to DATA READY
Home Position Signal No No
Paper End/Ribbon End Signal Yes No For S84-ex/S86-ex, when using the optional RFID
RFID Tag Error Signal Yes No When using the optional RFID
RFID Error Signal Yes No When using the optional RFID
Machine Error/ RFID Error Signal Yes No When using the optional RFID