IEEE1284

Basic Specifications

This interface complies with Centronics/IEEE1284 standard.

Interface

Amphenol 36P female

Communication Settings

The range of values in communication setting mode

Item Configuration Initial value
Protocol Status4, Status5, StatusL*1

CL4NX/CL6NX: Status4

LR4NX-FA: StatusL

BCC check for status5 Enabled / Disabled Disabled
  1. LR4NX-FA only

Connector

Printer side: Amphenol 36 pin (Female)

Cable side: Amphenol 36 pin (Male)

Cable Length

Equal to or less than 1.5 m

Signal Level

High level: +2.4 to +5.0 V

Low level: +0.0 to +0.4V

Receive Buffer Size

2.95 MB

Near Full

0MB

2.95MB

Remaining 0.95MB

Release Near Full

0MB

2.95MB

Remaining 1.95MB

Timing Chart

Send print data while the power of the printer is ON.

Turn off the printer when you disconnect interface cable.

Connection Diagram

Following is a parallel cable connection diagram.

Use a cable complies with IEEE1284 standard.

Connector Pin Assignment

See below for the connector pin assignment of Centronics standard (compatible mode).

When IEEE1284 standard connector is used, connection complies with IEEE1284-B type connector.

Pin no. Signal name Contents Pin no. Signal name Contents
1 STROBE Input 19 STROBE-RETURN
2 DATA 1 Input 20 DATA 1-RETURN
3 DATA 2 Input 21 DATA 2-RETURN
4 DATA 3 Input 22 DATA 3-RETURN
5 DATA 4 Input 23 DATA 4-RETURN
6 DATA 5 Input 24 DATA 5-RETURN
7 DATA 6 Input 25 DATA 6-RETURN
8 DATA 7 Input 26 DATA 7-RETURN
9 DATA 8 Input 27 DATA 8-RETURN
10 ACK Output 28 ACK-RETURN
11 BUSY Output 29 BUSY-RETURN
12 PE Output 30 PE-RETURN
13 SELECT Output 31 INIT Input
14 AUTOFD Input 32 FAULT Output
15 33
16 LOGIC GND 34
17 CHASSIS GND 35
18 PERIPHERAL LOGIC HIGH Input 36 SELECTION Input

I/O Signal

The details of each signal line for the Centronics standard (compatible mode) are as follows.

Note that each signal line complies with the IEEE1284 standard.

Pin no. Signal name I/O Contents
1 STROBE Input Synchronization signal that requires low active pulse to read DATA1 to DATA8
2 to 9 DATA 1 to DATA 8 Input Data entry of 8 bits parallel: DATA1 is LSB (lowest bit) and DATA8 is MSB (highest bit).
10 ACK Output Low active pulse signal indicating the completion of receive data import
11 BUSY Output High active signal indicating that the printer is not ready to receive data
12 PE Output High active signal indicating paper shortage
13 SELECT Output High active signal indicating that the printer is ready to receive data
14 AUTOFD Input Signal for the IEEE1284 standard
17 CHASSIS GND Connecting to the chassis ground
18 PERIPHERAL LOGIC HIGH Output +5V voltage on the printer side
19 to 30 SIGNAL GROUND Connecting to each signal ground
31 INIT Input Low active pulse signal initializing the printer
32 FAULT Output Low active pulse signal indicating an error in the printer
36 SELECTIN Input Signal for the IEEE1284 standard

Timing Chart of Multiple Receive

LR4NX-FA

Normal process

Process at the paper end

CL4NX/CL6NX

Normal process

Process at the paper end