Basic Specifications
This interface complies with Centronics/IEEE1284 standard.
Interface
Amphenol 36P female

Communication Settings
The range of values in communication setting mode
| Item | Configuration | Initial value |
|---|---|---|
| Protocol | Status4, Status5, StatusL*1 |
CL4NX/CL6NX: Status4 LR4NX-FA: StatusL |
| BCC check for status5 | Enabled / Disabled | Disabled |
- LR4NX-FA only
Connector
Printer side: Amphenol 36 pin (Female)
Cable side: Amphenol 36 pin (Male)
Cable Length
Equal to or less than 1.5 m
Signal Level
High level: +2.4 to +5.0 V
Low level: +0.0 to +0.4V
Receive Buffer Size
2.95 MB
0MB
2.95MB
Remaining 0.95MB
0MB
2.95MB
Remaining 1.95MB
Timing Chart

Send print data while the power of the printer is ON.
Turn off the printer when you disconnect interface cable.
Connection Diagram
Following is a parallel cable connection diagram.
Use a cable complies with IEEE1284 standard.

Connector Pin Assignment
See below for the connector pin assignment of Centronics standard (compatible mode).
When IEEE1284 standard connector is used, connection complies with IEEE1284-B type connector.
| Pin no. | Signal name | Contents | Pin no. | Signal name | Contents |
|---|---|---|---|---|---|
| 1 | STROBE | Input | 19 | STROBE-RETURN | |
| 2 | DATA 1 | Input | 20 | DATA 1-RETURN | |
| 3 | DATA 2 | Input | 21 | DATA 2-RETURN | |
| 4 | DATA 3 | Input | 22 | DATA 3-RETURN | |
| 5 | DATA 4 | Input | 23 | DATA 4-RETURN | |
| 6 | DATA 5 | Input | 24 | DATA 5-RETURN | |
| 7 | DATA 6 | Input | 25 | DATA 6-RETURN | |
| 8 | DATA 7 | Input | 26 | DATA 7-RETURN | |
| 9 | DATA 8 | Input | 27 | DATA 8-RETURN | |
| 10 | ACK | Output | 28 | ACK-RETURN | |
| 11 | BUSY | Output | 29 | BUSY-RETURN | |
| 12 | PE | Output | 30 | PE-RETURN | |
| 13 | SELECT | Output | 31 | INIT | Input |
| 14 | AUTOFD | Input | 32 | FAULT | Output |
| 15 | 33 | ||||
| 16 | LOGIC GND | 34 | |||
| 17 | CHASSIS GND | 35 | |||
| 18 | PERIPHERAL LOGIC HIGH | Input | 36 | SELECTION | Input |
I/O Signal
The details of each signal line for the Centronics standard (compatible mode) are as follows.
Note that each signal line complies with the IEEE1284 standard.
| Pin no. | Signal name | I/O | Contents |
|---|---|---|---|
| 1 | STROBE | Input | Synchronization signal that requires low active pulse to read DATA1 to DATA8 |
| 2 to 9 | DATA 1 to DATA 8 | Input | Data entry of 8 bits parallel: DATA1 is LSB (lowest bit) and DATA8 is MSB (highest bit). |
| 10 | ACK | Output | Low active pulse signal indicating the completion of receive data import |
| 11 | BUSY | Output | High active signal indicating that the printer is not ready to receive data |
| 12 | PE | Output | High active signal indicating paper shortage |
| 13 | SELECT | Output | High active signal indicating that the printer is ready to receive data |
| 14 | AUTOFD | Input | Signal for the IEEE1284 standard |
| 17 | CHASSIS GND | Connecting to the chassis ground | |
| 18 | PERIPHERAL LOGIC HIGH | Output | +5V voltage on the printer side |
| 19 to 30 | SIGNAL GROUND | Connecting to each signal ground | |
| 31 | INIT | Input | Low active pulse signal initializing the printer |
| 32 | FAULT | Output | Low active pulse signal indicating an error in the printer |
| 36 | SELECTIN | Input | Signal for the IEEE1284 standard |
Timing Chart of Multiple Receive
LR4NX-FA
Normal process

Process at the paper end

CL4NX/CL6NX
Normal process

Process at the paper end