TOP > Adjusting the Product > Adjusting the Base Reference Point > About the Base Reference Point About the Base Reference Point The base reference point is the point at which one determines the print position and stop/cut/dispensing position. The base reference point differs depending on the operation mode or media sensor you use. Continuous Mode/Tear-off Mode I-mark Label Gap Label (1) Feed direction (2) Print and stop position (1) Feed direction (2) Print and stop position Cutter Mode I-mark Label Gap Label (1) Feed direction (2) Print and cut position (1) Feed direction (2) Cut position (3) Print position Dispenser Mode I-mark Label Gap Label (1) Feed direction (2) Print and dispensing position (1) Feed direction (2) Dispensing position (3) Print position Linerless Mode (CL4NX Plus only) I-mark Linerless Label (1) Feed direction (2) Cut position (3) Print position (4) Non-printable zone (5 mm / 0.2") Back to top