[ESC+/X] Set XML Variable Name
CL4NX
CL6NX
CL4NX-J
CL6NX-J
PW208/PW208m
PW208NX/PW208mNX
FX3-LX
CT4-LX/HC4-LX
PW4NX
LR4NX-FA
S84NX/S86NX
CL4-SXR
CL6-SXR
Hexadecimal code
| ESC | <1B>16 |
|---|---|
| /X | <2F>16<58>16 |
Parameter
,a,b,n...n
Initial value
a = 0
Valid range and term of command
| When the power switch is OFF | The set parameter is maintained. |
| Valid range within items | The set parameter becomes invalid. |
| Valid range between items | The set parameter becomes invalid. |
Function
To set the XML variable field name for the format field number.
Format
</X>,a,b,n...n
- Parameter
a [Field number] = 01 - 99
b [Max field length] = 01 - 99
n...n [XML Variable Name] = Up to maximum 60 ASCII characters
Coding Example
Assign XML variable name ProductID to the field number 14, with Maximum input field length up to 10 characters.
<A>
<CC>1
<YS>,1
</Y>,Material Label
</X>,14,10,ProductID
<%>0<V>100<H>200<P>2<L>0101<XM>
<Z>
Supplementary Explanation
- This command should be used together with the template format registration command <YS>.
- Please refer to valid command list from [ESC+/N] Registration of Field